<br />*~-INFiCTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST ** <br /> <br />COMPONENTS <br /> <br />:=============================================================================== <br /> <br />CHECK <br /> <br />SECTION <br /> <br />REQUIREMENTS FOR EACH PRACTICE <br /> <br />~============================================================================== <br /> <br />PRACTICE #1 <br /> <br />606.1 <br /> <br />COMPLY WITH ALL INFILTRATION PRESCRIPTIVES. <br /> <br />-------------------------------------------------------------------------------- <br /> <br />l"J i ndov-JS <br /> <br />606.1 <br /> <br />Maximum of 0.34 CFM per linear foot of operable sash <br />crack (includes sliding glass doors). <br /> <br />Exterior & <br />(\djacent Doors <br /> <br />-------------------------------------------------------------------------------- <br /> <br />606.1 <br /> <br />Maximum of 0.5 CFM per sq. ft. of door area: solid <br />core, wood panel,insulated or glass doors only. <br /> <br />------------------------------------------------------------------------------- <br /> <br />r:::<ter ior Joi nts <br />;~ Cracks <br /> <br />606.1 <br /> <br />To be caulked, gasketed, weather-stripped or other- <br />wise sealed. <br /> <br />-.---------------------------------------------------------------------.---------- <br /> <br />PRACTICE #2 <br /> <br />606.1 <br /> <br />COMPLY WITH PRACTICE #1 AND THE FOLLOWING: <br /> <br />--------------------------------------------------------------------------------- <br /> <br />[-~)(terior l.Jalls <br />':;' F loo)'s <br /> <br />606.1 <br /> <br />Top plate penetrations sealed. Infiltration barrier <br />installed. Sole plate/floor joint caulked or sealed. <br /> <br />.---------------------------------------------------------------------------------- <br /> <br />-::xter iO)- loJalls <br />",.. Ceilings <br /> <br />E.,06 . 1 <br /> <br />Penetrations, joints and cracks on interior surface <br />caulked, sealed or gasketed. <br /> <br />----------------------------------------------------------.----------------------- <br /> <br />)ucUJor k <br /> <br />606.1 <br /> <br />Ductwork in unconditioned space must be sealed. <br /> <br />..------------------------------------------------------------------------------ <br /> <br />=ireplaces <br /> <br />606.1 <br /> <br />Equipped with outside combustion air, doors and flue <br />dampr,:,rs. <br /> <br />..------------------.------------------------------------.--------------------------- <br /> <br />~xhaust Fans <br /> <br />606.1 <br /> <br />Equipped with dampers. Combustion devices see <br />606.1.A.2. <br /> <br />---------------------------------------------------------------------.------------- <br /> <br />::ombustion <br />ippliances <br /> <br />606.1 <br /> <br />Be in unconditioned space (except direct vent), draw <br />air from unconditioned space, exhaust to outside. <br />Cooking appliances shall be dampered and use <br />intermittent ignition. <br /> <br />------------------------------------------------------------------------------- <br /> <br />,* OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) ** <br /> <br />.------------------------------------------------------------------------------ <br /> <br />Jater Heaters <br /> <br />612.1 <br /> <br />Comply with efficiency requirements in Table 6-12. <br />Switch or clearly marked circuit breaker (electric) <br />or cutoff (gas) must be provided. External or built- <br />in heat trap required. <br /> <br />.--------------------------------------------------.-------------------------------- <br /> <br />,~'_limmi ng Pools <br />Spas <br /> <br />612.1 <br /> <br />Spas and heated pools must have covers (except solar <br />heated). Non-commercial pools must have a pump timer. <br />Gas spa & pool heaters must have a minimum thermal <br />efficiency of 78 percent. <br /> <br />hOv-Je)- Heads <br /> <br />--------------_._------------------------------------~-------------------~-------- <br /> <br />t.Jater flow must be rest.,-ict.ed to no mor,,, t.han :3 gal- <br />lons per minute at 80 PSIG. <br /> <br />612.1 <br /> <br />-------------------------------------------------------------------------------- <br /> <br />VAC Duct <br />onstruction <br />nsulat,ion & <br />nstallation <br /> <br />610.1 <br /> <br />All ducts, fittings, mechanical equipment and plenum <br />chambers shall be mechanically attached, sealed, ins- <br />ulated and installed i~ accordance with the criteria <br />of Section 610.1 .ABC.2 & 610.1.ABC.3. Duct in attics <br />must be insulated to a minimum of R-6. Air handlers <br />shall not be installed in attics unless in mechanical <br />closet, <br /> <br />---------------------------------------------------------------------------------- <br /> <br />VAC Co nt.)- 0 1 s <br /> <br />607.1 <br /> <br />------------------------------------.-------------------------------------------- <br /> <br />Separate readily accessible manual or automatic <br />thermostat for each system. <br /> <br />nsulation <br /> <br />604.1 <br />602.1 <br /> <br />Ceilings minimum R-19. Common Walls - Frame R-11 or <br />CBS R-3 bot.h sides. Common ceiling & floors R-11. <br />