Laserfiche WebLink
<br />SERIAL # 515'3 <br />* ResmanuJ(c) * 04-05-1'3'35 <br />WHOLE HOUSE <br />HEAT GAIN / HEAT LOSS CALCULATION USING FLA/RES(c) DATA FILES <br />(BASED ON A.C.C.A. MANUAL J - SEVENTH EDITION (el 1986 by A.C.C.A.) <br /> <br />-.---.--------.---------..-----------.-----------------.--------.-----------------.-----.--------------------. <br /> <br />PROJECT :Mir"'age <br />ADDRESS :8 / Trc C / Brentwood <br />CITY :Silver Oaks, Zephryhills <br />OWNER :M / M Maltese <br />BLDG CONTR :Bluestone Construction <br />HVAC CONTR :CJ's Heating & Air Conditioning, Inc. <br />Cond FIr Area: 1763 SF * GLASS/SF RATIO - 18.3% * House Faces: North <br />* Climatic Conditions & Design Conditions * <br /> <br />Geographical Location: Florida <br /> <br />-..-.-.--..-........-.-.--------------..--.-------....---------________.._______..________.__.._.....__..N............_.....,................__.._._._._. <br /> <br />Lakeland <br /> <br />......-.-.......-.------.-.-.-........------.------...-------------------..-------.------.----.----.--.-------.-.-----.--.-.- <br /> <br />North latitude / Elevation <br />Outdoor Winter Dry Bulb <br />Indoor Winter Dry Bulb <br />Winter (Actual) Temp.Diff. <br />Winter" Temp. Diff. (wTd) <br />Outdoor Summer Dry Bulb <br />Outdoor Summer Wet Bulb <br />Outdoor Summer Hum. Ratio Gr/Lb <br />Indoor Summer Relaltive Hum. <br />Indoor Summer Design Gr/Lb. <br />Indoor Summer Dry Bulb <br />Indoor Summer Wet Bulb <br />Summer Daily Range <br />Summer (Actual) Temp.Diff. <br />!3ummf.?r"' (Us~er- Sf?l) TE\mp.Diff. (sTd) <br /> <br />28 Deg. / 214 Ft. Above Sea Level <br />4:1. De~J. F <br />70 Deg. F <br />2'3 Deg. F <br />40 Df.:~~~. F <br />':H Deg. F <br />76 Deg. F <br />113 <br /> <br />5~5 % <br /> <br />48 <br />75 Deg. F' <br />63.8 Deg. F @ 7:1. Gr/Lb <br />17 Df.::g. F M <br />16 Deg. F <br />15 De9. F <br /> <br />* HEATING SUMMARY * 0060 <br /> <br />.-". .... .,.. .... .... ~.. .... .... .... .... .... MO' .... -... M" -.' .... .... .... .... _. M" ,~.. .... h" _u _.' u.. _.. .... .... _.. .... .... .... .._ .... .... .... .... .... ,._ .... M" _00 .._ .._ _.. .... .... .... .... _., .... .... .... MO' .... M.. .... ." .... ... m. .... .... h" .... .... M.. .... .... <br /> <br />.DAT * COOLING SUMMARY * <br /> <br />SUBTOTAL 40637.0'3 ISTRUCTURE SENSIBLE <br />:MECH.VENT- 150 Cfm <br />:SENS. + MECH.VENT <br />:TEMP.SWING @ 3 DEG. <br />: OCCUPANT/APPLIANCE <br />DUCT LOSS 2031.85 :DUCT GAIN <br />TOTAL LOSS/BTUH 42668.94 :TOTAL SENSIBLE <br />lTOTAL LATENT <br /> <br />:SENSIBLE + LATENT <br />20% OVERSIZE FACTOR 8533.7'3 /20% SENS.OVRSZE FTR: <br />ACTUAL + 20% OVERSIZE: 51202.73 ISENS. + 20% OVERSIZE: <br /> <br />* EQUIPMENT SELECTION * <br /> <br />LQT MANUF TRANE <br />HTG INP/BTUH 32600 <br />SENSIBLE BTUH 23800 <br />TONAGE 2.9 (S)EER 10 <br />NOTES: <br /> <br />CU MOD # TWR036C100A <br />HTG OUTP/BTUH 32600 <br />LATENT BTUH 11400 <br />CLG CFM 1200 <br /> <br />AHU MOD # TWE036C140 <br />AFUE/HSPF 6.'3 TYPE HP <br />TTL CLG BTUH 35200 <br />HTG CFM :1.200 <br /> <br />20581.04 <br />2640.00 <br /> <br />:23:::':~:;~ 1. . ()4 <br /> <br />1.00 <br />3000.00 <br />262:;;::. 10 <br />28843.14 <br />13870.67 <br /> <br />37713.81 <br />5768.63 <br />34611.77 <br /> <br />---------------------------------------------------------------- <br />