Laserfiche WebLink
<br />GLASS ~OlOlMS: SOlliD WALLS AND COlVER <br /> <br />'~ <br /> <br />TABLE 3: MAXIMUM HEIGHT OF UPRIGHTS FOR SCREEN AND GLASS ROOMS <br />EXTRUSTIONS AND SELF MATING BEAMS OF 6063 T -6 ALUMINUM ALLOY <br /> <br />USING SCREEN PANEL WIDTH "w" (SEE TYPICAL GLASS ROOM DRAWING), SELECT <br />UPRIGHT REQUIRED FROM THE MAX HEIGHT ALLOWED FOR EACH EXTRUSION <br /> <br /> WIDTH "w" <br /> 36" 42" 48" 54" 60" 66" 72" 78" <br /> EXTRUSION <br /> 2"x 2"x 0.044" <br /> " g'- 2" 8'- 6" 7'-11 " 7'- 6" 7'- 1 " 6'- g" <br /> I 2"x 2"x 0.050" <br /> 10'- 2" g'- 5" 8'-10" 8'- 2" 7'-11 " 7'- 6" }'- 2" 6'-11" <br />. , 2"x 2"x 0.093" <br /> 12'-10" 11'-11" 11'- 1 " 10'- 6" g' -11" 9'- 6" 9'.- 1 " 8'- 8" <br /> 3"x 2"x 0.050" <br /> 10'- 8" g' -11" g'- 3" 8'- g" 8'- 3" 7'-11 " 71- 6" 7'- 3" <br /> 2"x 3"x 0.050" <br /> 12'-10" 11'-11" 11'- 1 " 10'- 6" g' -11" g'- 6" 9'.- 1 " 8'- 8" <br /> 3"x 2"x 0.070" <br /> 13'- 8" 12'- 8" 11'-10" 11 '- 2" 10'- 6" 10'- 1 " g'- 8" g'- 3" <br /> <br />NOTES: GLASS ROOMS THE ADDITION OF AN ALUMINUM FRAME Wlt~DOWS Wi GLASS <br />PANES THAT ARE DESIGNED TO 110 MPH WIND LOAD REQUIREMENTS TO THE <br />ABOVE UPRIGHT SIZES INCREASES THE STRENGTH SO THAT ADDITIONAL <br />FRAMING IS NOT REQUIRED. <br /> <br />) <br />--- <br /> <br />[b@W[]'@OD@@ [go m@Oi)Oi)@~~g [PO[gO <br />CIVIL ENGINEER AND DEVELOPMENT CONSULTANT <br />P.O. BOX 4369 S. DAYTONA, FLORIDA 32121-4368 <br />PHONE: (904) 767-4774 <br />FAX: (904) 767-6556 <br /> <br />'. ----,; <br /> <br />@ COPYRIGHT, 1995 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN <br />PERMISSION FROM LAWRENCE E. BENNETT, P.E. <br /> <br />SECTION: 5 <br />PAGE: ~O~~~ <br /> <br />-83- <br />