Laserfiche WebLink
<br />Department of Community Affairs <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />FORM 600A-93 Residential Whole Building Performance Method A <br />PROJECT NAME: O~KCRES1~TATES :BUILDER: GEBHART CONSTRUCTIO~) <br />AND ADDRESS: <3 ~'las: & ~ : PERMITTING : CLIMAT~ <br />ZEPHYRHILL , FLORIDA: OFFICE: ZEPHYRHILLS : ZONE: 7:_: 8:_: 9:_: <br />OWNER: :PERMIT NO.S-~Ob /3 :JURISDICTION NO. f:,fl!c{) 0 <br />CK <br /> <br />j--2d/r;: <br /> <br />L. New construction or addition <br />~. Single family detached or Multifamily attached <br />l. If MUltifamily-No. of units <br />b. If Multifamily, is this a worst case (yes/no) <br />I. Conditioned floor area (sq.ft.) <br />). Predominant eave overhang (ft.) <br />, Porch overhang length (ft.) <br />I. Glass area and type: <br />a. Clear Glass <br />b. Tint, film or solar screen <br />I. Floor type and insulation: <br />a. Slab on grade (R-value, perimeter) <br />.0.Net Wall type area and insulation: <br />a. Exterior: 1. Concrete (Insulation R-value) <br />b. Adjacent: 2. Wood frame (Insulation R-value) <br />,l.Ceiling type area and insulation: <br />a. Under attic (Insulation R-value) <br />2.Air distribution systems <br />a. Ducts (Insulation + Location) <br />3.Cooling system <br /> <br />4.Heating System: <br /> <br />5.Hot water system: <br /> <br />6.Hot Water Credits: (HR-Heat Recovery, <br />DHP-Dedicated Heat Pump) <br />7.Infiltration practice: 1, 2 or 3 <br />8.HVAC Credits (CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, RB-Attic radiant <br />barrier, MZ-Multizone) <br />9.EPI (must not exceed 100 points) <br />a. Total As-Built points <br />b. Total Base points <br /> <br />SN: 7355 <br /> <br />SOUTH <br /> <br />1. <br />2. <br />3. <br />4. <br />5. 1429.00 <br />6. 1. 00 <br />7. 13.40 <br />Single Pane <br />8a.190.6sqft <br />8b. O.Osqft <br /> <br />New Construction <br />Single-Family <br />o <br /> <br />Double Pane <br />O.OOsqft <br />O.OOsqft <br /> <br />9a.R= 6.00 , 199.00 ft <br /> <br />10a-1 R= 7.00, 1094.35sqft____ <br />10b-2 R=13.00, 237.00sqft____ <br /> <br />11a.R=22.00 , 1429.00sqft____ <br /> <br />12a. R= 6.00, uncond <br />13. Type: Central A/C <br />SEER: 10.00 <br />14. Type: Strip Heat <br />COP: 1.00 <br />15. Type: Electric <br />EF: 0.95 <br /> <br />16. <br /> <br />17. <br />18. <br /> <br />2 <br /> <br />RB <br /> <br />19. <br />19a. <br />19b. <br /> <br />93.28 <br />26333.72 <br />28230.71 <br /> <br />------------------------------------------------------------------------------ <br /> <br />------------------------------------------------------------------------------ <br /> <br />Hereby certify that the plans and <br />pecifications covered by this calcu- <br />ation are in compliance with the <br />lorida Ene~ !lt5.. -'. <br /> <br />REPARED BY. c ~ <br />t\.TE: - 6-q) <br /> <br />Review of the plans and specifications <br />covered by this calculation indicates <br />compliance with the Florida Energy <br />Code. Before construction is completed <br />this bUilding will be inspected for <br />compliance in accordance with Section <br />553.908 F.S. <br /> <br />hereby certify that this building is <br />1 compliance with the Florida Energy <br />)de. <br /> <br />mER/AGENT: <br />~TE : <br /> <br />BUILDING OFFICIAL~~A H..q ~f)~ <br />DATE: 8-cJ---- <br />