Laserfiche WebLink
<br />~* INFtLTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST ** <br /> <br />=============='================================================================ <br /> <br />OMPONENTS <br /> <br />SECTION <br /> <br />REQUIREMENTS FOR EACH PRACTICE <br /> <br />CHECK <br /> <br />============================================================================== <br /> <br />RACTICE #1 <br /> <br />606.1 <br /> <br />COMPLY WITH ALL INFILTRATION PRESCRIPTIVES. <br /> <br />indows <br /> <br />------------------------------------------------------------------------------ <br /> <br />606.1 <br /> <br />Maximum of 0.34 CFM per linear foot of operable sash <br />crack (includes sliding glass doors). <br /> <br />------------------------------------------------------------------------------ <br /> <br />xterior & <br />djacent Doors <br /> <br />606.1 <br /> <br />Maximum of 0.5 CFM per sq. ft. of door area: solid <br />core, wood panel,insulated or glass doors only. <br /> <br />------------------------------------------------------------------------------ <br /> <br />xterior Joints <br />Cracks <br /> <br />606.1 <br /> <br />To be caulked, gasketed, weather-stripped or other- <br />wise sealed. <br /> <br />RACTICE #2 <br /> <br />------------------------------------------------------------------------------ <br /> <br />COMPLY WITH PRACTICE #1 AND THE FOLLOWING: <br /> <br />606.1 <br /> <br />------------------------------------------------------------------------------ <br /> <br />xterior Walls <br />Floors <br /> <br />xterior Walls <br />Ceilings <br /> <br />uctWork <br /> <br />'ireplaces <br /> <br />xhaust Fans <br /> <br />ombustion <br />eating <br /> <br />606.1 <br /> <br />606.1 <br /> <br />606.1 <br /> <br />606.1 <br /> <br />606.1 <br /> <br />606.1 <br /> <br />Top plate penetrations sealed. Infiltration barrier <br />installed. Sole plate/floor joint caulked or sealed. <br /> <br />Penetrations, joints and cracks on interior surface <br />caulked, sealed or gasketed. <br /> <br />Ductwork in unconditioned space must be sealed. <br /> <br />Equipped with outside combustion air, doors and flue <br />dampers. <br /> <br />Equipped with dampers. Combustion devices see <br />606.1.A.2. <br /> <br />Combustion space and water heating systems provided <br />with outside combustion air, except direct vent <br />appliances. <br /> <br />* OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) ** <br /> <br />'a ter Heaters <br /> <br />wimming Pools <br />Spas <br /> <br />612.1 <br /> <br />612.1 <br /> <br />Comply with efficiency requirements in Table 6-11. <br />Switch or clearly marked circuit breaker (electric) <br />or cutoff (gas) must be provided. External or built- <br />in heat trap required. <br /> <br />Spas and heated pools must have covers (except solar <br />heated). Non-commercial pools must have a pump timer. <br />Gas spa & pool heaters must have a minimum thermal <br />efficiency of 78 percent. <br /> <br />hower Heads <br /> <br />------------------------------------------------------------------------------ <br /> <br />612.1 <br /> <br />Water flow must be restricted to no more than 3 gal- <br />lons per minute at 80 PSIG. <br /> <br />------------------------------------------------------------------------------ <br /> <br />.ir Distribution 610.1 <br />ystems <br /> <br />All ducts, fittings, mechanical equipment and plenum <br />chambers shall be mechanically attached, sealed, ins- <br />ulated and installed in accordance with the criteria <br />of Section 610. Ducts in unconditioned attics must <br />be insulated to a minimum of R-6. Air handlers shall <br />not be installed in attics unless in mechanical <br />closet. <br /> <br />------------------------------------------------------------------------------ <br /> <br />VAC Controls <br /> <br />607.1 <br /> <br />Separate readily accessible manual or automatic <br />thermostat for each system. <br /> <br />------------------------------------------------------------------------------ <br />