Laserfiche WebLink
<br />DANSCO ENGINEERING, P.A. <br />P.O. BOX 3916 APOLLO BEACH, FL 33572 (813)645-0166 <br />Copyright 1993 by Tondelli Engineering, P.A. Tampa, Florida <br />CUSTOMER : SUMMER HILL BUILDERS <br />JOB NUMBER : 950897 DATE : 05-09-1995 <br />DESCRIPTION : ISLAND <br /> <br />*** DESIGN WIND LOADS - 1991/1992 STANDARD BUILDING CODE *** <br />*** COMPONENTS AND CLADDING *** <br />ENCLOSED BUILDING <br /> <br />WIND VELOCITY <br />MEAN ROOF HEIGHT <br />VELOCITY PRESSURE <br />USE FACTOR <br /> <br />100 MPH <br />15.0 FT <br />21.00 PSF <br />1. 00 <br /> <br />ROOF SLOPE <br />TRIBUTARY AREA <br /> <br />6 . 00 : 12 (26 . 56 DEG) <br />240.0 FT2 <br /> <br /> WALL WIND LOADS <br /> WALL AREA <br /> w e <br />GCp (+ ) 1.056 1.056 <br />GCp ( - ) -1.138 -1.175 <br />PRESSURE 22.2 22.2 <br />(PSF) <br />SUCTION -23.9 -24.7 <br />(PSF) <br /> <br />+ <br />++ ++ <br />++ ++ <br /> <br />iJ <br /> <br />w <br /> <br />Ii <br /> <br />z <br /> <br />w <br /> <br />BUILDING WIDTH <br />e CORNER DISTANCE, Z <br /> <br />48 . 0 FT <br />4.8 FT <br />