95-5355
Zephyrhills
>
Building Department
>
Permits
>
1995
>
95-5355
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 2:39:27 PM
Creation date
7/5/2006 11:41:43 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
95-5355
Building Department - Name
EMERALD POINT CORP
Address
39630 CHANCEY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />AIR SYSTEM DESIGN LOAD SUMMARY <br />.~JJltRer~~~:~ f~~~~hi Ils, F lor ida H~~-93:-&~ <br />Prepared By: PHILLIP ALVAREZ Page 1 of 1 <br />************************************************************************* <br /> <br />+------------------------------------------------------------------------+ <br /> <br />COOLING AT. .......: Aug @ 1400 HEATING AT......: Winter Design: <br />I COOLING OA DB/RH..: 91.5 F / 52 % HEATING OA DB...: 36.0 F ~ <br /> <br />+------------------------+--------------+--------------------+----------+ <br /> <br />: :: COO L I N G : HEATING: <br />: :: Sensible Latent: Sensible : <br />: ZONE LOADS : Details : (BTU/hr) (BTU/hr) : (BTU/hr) : <br /> <br />+------------------------+--------------+---------------------+----------+ <br /> <br />Solar Loads : 135 sqft: 4671 : : <br />Wall Transmission : 775 sqft: 5951 : 7556 : <br />Roof Transmission : 1035 sqft: 3309 : 1633 : <br />Glass Transmission : 135 sqft: 1980 : 5019 : <br />Skylight Transmission: 0 sqft 0 : 0 <br />Door Transmission : 0 sqft 0 : 0 <br />Floor Transmission : 1035 sqft 0 '341 <br />Partitions : 0 sqft 0 0 <br />Ceiling 0 sqft 0 0 <br />Lighting 2.00 W/sqft 7063 <br />Equipment 0.50 W/$qft 1766 <br />People 10 people, 2450 2050 <br />Infiltration : 0 0 0 <br />Miscellaneous : 0 0 <br />Safety Factor 0/ 0/ 0 %: 0 0 , 0 <br /> <br />+------------------------+--------------+--------------------+----------+ <br /> <br />: > > Total Zone Loads (1) : : 27189 2050: 14549: <br /> <br />+------------------------+--------------+---------------------+---------~+ <br /> <br />: Zone Conditioning (2) : 27207 2050 16947 <br />: Plenum Wall Load : 0 % 0 <br />: Plenum Roof Load : 0 % 0 <br />: Plenum Lighting Load: 0 % 0 <br />: Return Fan Load: 0 0 <br />: Ventilation Load : 150 CFM 2669 5526 5219 <br />: Supply Fan Load :. 1260 CFM 467 -467 <br />: Space Fan Coil Fans : 0 0 <br />: Duct Heat Gai n/Loss : 0 % I 0 I 0 I <br /> <br />+------------------------+--------------+----------------_._--+-----~----+ <br /> <br />: > > Total System Loads : : 30343 7!:,76: 21699: <br /> <br />+------------------------+--------------+-----------------.---+----------+ <br /> <br />: Central Cooling Coil : : 30343 7680 : 0 : <br />: Central Heating Coil : : 0 : 21699 <br />: Precool Coil : : 0 0 : 0 <br />: Preheat Coil : : 0 : 0 <br />: Central Reheat Coil: : 0 : <br />: Humidification Load: : 0 0 : <br />: Terminal Reheat Coils : : 0 : 0 <br />: Space/Skin Heat Coils : : 0 : 0 <br /> <br />+------------------------+--------------+-----------------.---+----------+ <br /> <br />: >>Total Conditioning : 30343 7680: 21699: <br /> <br />+------------------------+--------------+-----------------.---+----------+ <br /> <br />Notes: (1) Zone loads calculated at occupied thermostat setpoint. <br />(2) Zone conditioning based on heat extraction analysis. <br />(3) In the COOLING column, positive loads indicate heat gains, <br />while positive coil loads indicate system heat removal. <br />(4) In the HEATING column, positive loads indicate heat loss, <br />while positive coil loads indicate system heat addition. <br />