My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
95-5355
Zephyrhills
>
Building Department
>
Permits
>
1995
>
95-5355
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 2:39:27 PM
Creation date
7/5/2006 11:41:43 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
95-5355
Building Department - Name
EMERALD POINT CORP
Address
39630 CHANCEY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />AIR SYSTEM DESIGN LOAD SUMMARY <br />'~JXtR~r~~~ :':: 2'~~~y~hi Ils, F lor ida H~~-S:!::82' <br />Prepared By: PHILLIP ALVAREZ Page 1 of 1 <br />************************************************************************* <br /> <br />+-------------------------------------------------~-------.--------------+ <br /> <br />COOLING AT.... ....: Aug @ 1500 HEATING AT......: Winter Design: <br />I COOLING OA DB/RH..: 92.0 F / 51 % HEATING OA DB...: 36.0 F f <br /> <br />+------------------------+--------------+--------------------+----------+ <br /> <br />: : COO L I N G : HEATING: <br />: : Sensible Latent: Sensible : <br />: ZONE LOADS Deta i Is : (BTU/hr) ( BTU/hr) : (BTU/hr) : <br /> <br />+------------------------+--------------+-----------------.---+----------+ <br /> <br />Solar Loads 189 sqft: 4778 <br />Wall Transmission 971 sqft: 5944 <br />Roof Transmission 2780 sqft: 8195 <br />Glass Transmission 189 sqft: 2884 <br />Skylight Transmission 0 sqft: 0 <br />Door Transmission 0 sqft: 0 <br />Floor Transmission 2780 sqft: 0 <br />Partitions 0 sqft: 0 <br />Ceiling 0 sqft: 0 <br />Lighting 2.00 W/sqft 18970 <br />Equipment 0.50 W/sqft 4743 <br />People 100 people 24500 20500 <br />Infiltration 0 0 <br />Miscellaneous 0 0 <br />Safety Factor 0/ 0/ 0 % 0 0 I 0 <br /> <br />+------------------------+--------------+---------------------+----------+ <br /> <br />: > >Total Zone Loads (1) : : 70014 20500: 21292 .: <br /> <br />+------------------------+--------------+---------------------+----------+ <br /> <br />: Zone Conditioning (2) : 69704 20500 27628 <br />: Plenum Wall Load : 0 % 0 <br />Plenum Roof Load : 0 % 0 <br />Plenum Lighting Load: 0 % 0 <br />Return Fan Load: 0 0 <br />Ventilation Load : 750 CFM 13731 23188 26093 <br />Supply Fan Load : 3327 CFM 1233 -1233 <br />Space Fan Coil Fans : 0 0 <br />Duct Heat Gain/Loss : 0 % 0 I 0 I <br /> <br />+------------------------+--------------+---------------------+----------+ <br /> <br />: >>Total System Loads : : 84668 43688: 52488: <br /> <br />+------------------------+--------------+-----------------.---+----------+ <br /> <br />: Central Cooling Coil : 84668 43740: 0 : <br />: Central Heating Coil : 0 : 52488: <br />: Precool Coil : 0 0 : 0 : <br />: Preheat Coil : 0 : 0 : <br />: Central Reheat Coil : 0 : : <br />: Humidification Load : 0 0 : : <br />: Terminal Reheat Coils : 0 : 0 : <br />: Space/Skin Heat Coils : 0 : 0 : <br /> <br />+------------------------+--------------+---------------------+----------+ <br /> <br />: >>Total Conditioning : : 84668 43740: 52488: <br /> <br />+------------------------+--------------+---------------------+----------+ <br /> <br />Notes: (1) Zone loads calculated at occupied thermostat setpoint. <br />(2) Zone conditioning based on heat extraction analysis. <br />(3) In the COOLING column( positive loads indicate heat gains, <br />while positive coil loads indicate system heat removal. <br />(4) In the HEATING column, positive loads indicate heat loss, <br />while positive coil loads indicate system heat addition. <br /> <br />9467 <br />4386 <br />7027 <br />o <br />o <br />412 <br />o <br />o <br /> <br />o <br />
The URL can be used to link to this page
Your browser does not support the video tag.