Laserfiche WebLink
<br />AIR SYSTEM DESIGN LOAD SUMMARY <br />t1~$tR~~.~~~ :-:: fl~~~yfhillS, Flor ida HA~-&~-:82l <br />Prepared By: PHILLIP ALVAREZ Page 1 oT 1 <br />************************************************************************* <br /> <br />+---------------------------------------------------------.--------------+ <br /> <br />COOLING AT........: Jul @ 1500 HEATING AT......: Winter Design: <br />I COOLING OA DB/RH..: 92.0 F / 51 % HEATING OA DB...: 36.0 F ~ <br /> <br />+------------------------+--------------+----------------_._--+----~-----+ <br /> <br />: :: COO L I N G : HEATING: <br />: :: Sensible Latent: Sensible : <br />: ZONE LOADS : Detai Is : (BTU/hr) (BTU/hr) : (BTU/hr) : <br /> <br />+------------------------+--------------+-----------------.---+----------+ <br /> <br />Solar Loads 108 sqft: 2446 I <br />Wall Transmission 412 sqft: 2268 4017 <br />Roof Transmission 1190 sqft: 3661 1877 <br />Glass Transmission 108 sqft: 1648 4015 <br />Skylight Transmission 0 sqft: 0 0 <br />Door Transmission 0 sqft: 0 0 <br />I Floor Transmission 1190 sqft: 0 351 <br />Partitions 0 sqft: 0 0 <br />Ceiling 0 sqft I 0 0 <br />Lighting 2.00 W/sqft 8120 <br />Equipment 0.50 W/sqft 2030 <br />People 10 people 2450 2050 <br />Infiltration 0 0 0 <br />Miscellaneous 0 0 <br />Safety Factor 0/ 0/ 0 % 0 0 0 <br /> <br />+------------------------+--------------+-----------------.---+----------+ <br /> <br />: ))Total Zone Loads (1) : 22624 2050: 10261: <br /> <br />+------------------------+--------------+-----------------.---+----------+ <br /> <br />Zone Conditioning (2) : 22635 2050 12485 <br />Plenum Wall Load : 0 % 0 <br />Plenum Roof Load : 0 % 0 <br />Plenum Lighting Load: 0 % 0 <br />Return Fan Load: 0 0 <br />Ventilation Load : 150 CFM 2751 5486 5186 <br />Supply Fan Load : 1048 CFM 389 -389 <br />Space Fan Coil Fans : 0 0 <br />Duct Heat Gain/C6ss : 0 % I 0 I 0 <br /> <br />+--~---------------------+--------------+-----------------.---+----------+ <br /> <br />: )) Total System Loads : : 25774 7536: 17282: <br /> <br />+------------------------+--------------+-----------------.---+----------+ <br /> <br />: Central Cooling Coil : I 25774 7555 : 0 : <br />: Central Heating Coil : 0: 17282: <br />: Precool Coil: 0 0 : 0 : <br />: Preheat Coil: 0: 0 : <br />: Central Reheat Coil : 0:: <br />: Humidification Load : 0 0 : : <br />: Terminal Reheat Coils : 0: 0 : <br />: Space/Skin Heat Coils : 0: 0 : <br /> <br />+------------------------+--------------+-----------------.---+----------+ <br /> <br />))Total Conditioning : : 25774 7555: 17282: <br /> <br />+------------------------+--------------+-----------------.---+----------+ <br /> <br />Notes: (1) Zone loads calculated at occupied thermostat setpoint. <br />(2) Zone conditioning based on heat extraction analysis. <br />(3) In the COOLING column, positive loads indicate heat gains, <br />while positive coil loads indicate system heat removal. <br />(4) In the HEATING column, positive loads indicate heat loss, <br />while positive coil loads indicate system heat addition. <br />