<br />~ Ih~~{~ <br /> <br />Department of Community Affairs - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTJ-ON <br />FORM 600A-93 Residential Whole Building Performance Method A CENTRAL <iJ5 6 <br /> <br />PROJECT NAME: <br />AND ADDRESS: <br /> <br /> <br /> <br />OWNER: <br /> <br />PERMIT NO. <br /> <br />1. New construction or addition <br />2. Single family detached or Multifamily attached <br />3. If Multifamily-No. of units covered by this submission <br />4. If Multifamily, is this a worst case (yes / no) <br />5. Conditioned floor area (sq. ft,) <br />6. Predominant eave overhang (ft,) <br />7. Porch overhang length (ft,) <br />8. Glass type and area: <br />a, Clear glass <br />b, Tint, film or solar screen <br />9. Floor type and insulation: <br />a, Slab on grade (R-value + perimeter) <br />b, Wood, raised (R-value + sq. f1.) <br />c. Concrete, raised (R-value) <br />10. Net Wall type, area and insulation: <br />a. Exterior: 1. Concrete block (Insulation R-value) <br />2, Wood frame (Insulation R-value) <br />3, Steel frame (Insulation R-value) <br />4, Log (Insulation R-value) <br /> <br />b. Adjacent: 1. Concrete block (Insulation R-value) <br />2, Wood frame (Insulation R-value) <br />3. Steel frame (Insulation R-value) <br />4. Log (Insulation R-value) <br />11. Ceiling type, area and insulation: <br />a, Under attic (Insulation R-value) <br />b. Single assembly (Insulation R-value) <br />12. Air distribution system: <br />a, Ducts (Insulation + Location) <br />b, Air Handler( Insulation + Location) <br />13. Cooling system: <br />(Types: central-split, central-single pkg" room unit, PTAC" none) <br /> <br />14. Heating system: <br />(Types: heat pump, elec. strip, nat. gas, L.P, gas, room or PTAC, none) <br />15. Hot water system: <br />(Types: elec" natural gas, solar, L.P, gas, none) <br />16. Hot Water Credits: <br />a. Heat Recovery (HR) <br />b. Dedicated Heat Pump(DHP) <br />17. Infiltration practice: 1,2 or 3 <br />18. HV AC Credits (Type in Letter designation: CF-Ceiling Fan, GV-Cross vent, <br />HF-Whole house fan, RS-Attic radiant barrier, MZ-Multizone) <br />19. EPI (must not exceed 100 points) <br /> <br />a. Total As-Built points <br />b. Total Base points <br /> <br />EPI = Total As-Built points X 100 <br />Total Base points <br /> <br /> <br />l DATE:' 1_~f}iJ <br /> <br />a Energy Coda, <br /> <br />12a. <br />12b. <br />13a. <br />13b. <br />13c. <br />14a. <br />14b. <br />14c. <br />15a. <br />15b. <br />16a. <br />16b. <br />17. <br />18. <br /> <br />'19. <br /> <br />19a. <br />19b. <br /> <br />CLIMATE D D <br />ZONE: 4 5 6 <br />JURISDlcnONNO.: ~ <br /> <br />CK <br /> <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br /> <br />A.I~ <br />~ <br />~ <br /> <br />"Z- <br /> <br />8a. <br />8b. <br /> <br />sq. ft. <br />ft. <br />ft. <br />Si~le p,a ne Double Pane <br />7 t ~ sq. ft. sq. ft. <br />sq, ft. sq. ft. <br /> <br />9a. R= C> , / ~ Y(, '\ I. ft. <br />9b. R= sq. ft, <br />9c, R= sq. ft. <br />1 Oa-1 R= c;- 'J-. " 1 sq. ft. <br />10a-2 R= sq. ft. <br />1 Oa-3 R= sq. ft. <br />1 Oa-4 R= sq. ft. <br />10b-l R= sq. ft. <br />10b-2 R= I I bif) sq. ft. <br />10b-3 R= sq. ft. <br />10b-4 R= sq. ft. <br />lla, R= ~O It t;( sq. ft. <br />llb, R= sq. ft. <br /> <br />R= (, , v ~ ~ '<cond.lunCOnd,) <br />R= Ltc ,)--)' , C DN t\ (oond.luncond,) <br />Type: a~v~( ~/) <br />SEERlEERlCOP: /~l 00 <br />Capacity: ~ ~ CD. 00 <br />Type: t?Ia c <br />HSPF/COP/AFUE: I <br />Capacity: /' '7 (!> () 0 <br />Type: L- { .e <br />EF: I 9 I <br /> <br />., <br />- <br /> <br />9f I <br />~O 0 ~ ( <br />;J.Drv7 <br /> <br />Review of plans and specifications covered by this calculation Indicates compliance with <br />the Florida Energy Code, Before construction is completed, this 001 wiN be inspected <br />for compliance In accordance' ion ,908. F,S, "" <br /> <br />OWNER AGENT: <br /> <br />DATE: <br /> <br /> <br />-1- <br /> <br />DATE: <br />