<br />ADDITIONAL TABLES <br /> <br />CLIMATE ZONES 4 S 6 <br /> <br />6A-18 HEATING CREDIT MULTIPLIERS (HCM) <br />SYSTEM TYPE HEATING CREDIT MULTIPLIERS (HCM) <br />Allie Radiant Barrier HCM ,98 <br />Multizone HCM , ,95 <br />Natural Gas AFUE ,68-,72 .73-,77 .78-,82 ,83-,87 ,88-,92 ,93 & Up <br />HCM ,61 ,56 ,53 ,50 ,47 ,44 <br />LP Gas HCM ,77 ,72 ,67 ,63 ,60 .57 <br /> <br />6A-19 COOLING CREDIT MULTIPLIERS CCM} <br />SYSTEM TYPE COOLING CREDIT MULTIPLIERS (CCM) <br />CeilinQ Fans ,86' <br />Cross Ventilation ,95' 'Credit may be taken for only <br />Whole House Fan ,95' one of these system types concurrently, <br />Multizone ,95 <br />Allie Radiant Barrier ,95 <br /> <br /> <br />Heat Recovery Unit <br /> <br />With <br />HW <br />EF <br />HWCM <br />F <br /> <br /> <br />Dedicated Heat Pump <br /> <br />Solar <br /> <br />A HWM MUST BE USED IN CONJUNCTION WITH ALL HWCM, SEE TABLE 6A'9, EF MEANS ENERGY FACTOR. <br /> <br />6A-21 INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST (SEE SECTION 606) <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE #1 606,1 COMPLY WITH All INFilTRATION PRESCRIPTIVES, <br />Windows Maximum of 0,34 CFM per linear foot of operable sash crack (includes slidino olass doors), <br />Exterior & Adiacent Doors Maximum of 0,5 CFM per sa, It, of door area; solid core wood panel, insulated or olass doors only, <br />Exterior Joints & Cracks To be caulked, aasketed weatherstriooed or otherwise sealed. <br />PRACTICE #2 606,1 COMPLY WITH #1 AND THE FOllOWING: <br />Exterior Walls and Floors Top plate penetrations sealed, Infiltration barrier installed, Sole olate/floor ioint caulked or sealed, <br />Exterior Walls & Ceilinas Penetrations, ioints and cracks on interior surface caulked, sealed or aasketed, <br />Ductwork Ductwork in unconditioned soace must be sealed, <br />Fireplaces Eauiooed with outside combustion air doors, and flue damoers, <br />Exhaust Fans Eauiooed with dampers, Combustion devices see 606,1.A.2 <br />PRACTICE #3 606,1 COMPLY WITH PRACTICES #1 AND #2 AND THE FOllOWING: <br />Ceilinas Infiltration barrier installed, <br />Interior Walls Top penetrations sealed or ioints & cracks on interior walls caulked sealed or oasketed, <br />Recessed LiQhts Sealed from conditioned & insulated from ventilated attic spaces, <br />Ductwork All ductwork located in conditioned soace, <br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust <br /> by-products to outside, Combustion cooking appliances see section 606,1.A.3 <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612,1 Comply with efficiency requirements in Table 6-11, Switch or clearly marked circuit breaker (electric) <br /> or cutoff (aas) must be orovided, External or built-in heat trap reauired, <br />Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated), Non-commercial pools must have <br /> a pump timer, Gas spa & pool heaters must have a minimum thermal efficiency of 78%, <br />Shower Heads 612,1 Water flow must be restricted to no more than 3 gallons per minute at 80 PSIG, <br />Air Distribution System 610,1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br /> sealed. insulated, and installed in accordance with the criteria of Section 61 0, Ducts in unconditioned <br /> attics must be insulated to a minimum of R-6, Air handlers shall not be installed in attics unless in <br /> mechanical closet. <br />HV AC Controls 607,1 Separate readilv accessible manual or automatic thermostat for each system, <br />Insulation 604,1, 602,1 Ceilinos-Min, R-19, Common walls-Frame R-11 orCBS R-3 both sides, Common ceiling & floors R-11, <br /> <br />,6- <br />