Laserfiche WebLink
<br />1_ ............ ,"''If. l~ .... _ .~.._. 1 <br /> <br />COMPONENTS <br /> <br />** INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLiST ** <br /> <br />===========================================================:=============.======= <br /> <br />SECTION <br /> <br />REQUIREMENTS FOR EACH PRACTICE <br /> <br />CHECI< <br /> <br />~=======~==================================================:==================== <br /> <br />peACT I CE it 1 <br /> <br />Windows <br /> <br />E:/;terior ~I <br />Adjacent Doors <br /> <br />606. 1 <br /> <br />606. 1 <br /> <br />606. 1 <br /> <br />COMPLY WITH ALL INFILTRATION PRESCRIPTIVES. <br /> <br />Maximum of 0.34 CFM per linear foot of operable sash <br />crack (includes sliding glass doors). <br /> <br />Maximum of 0.5 CFM per sq. ft. of door area: solid <br />core, wood panel, insulated or glass doors only. <br /> <br />----.------.--.------------------------------------------------------------------- <br /> <br />E~;ter ior Joi nts <br />~I Cracks <br /> <br />606. 1 <br /> <br />To be caulked, gasketed, weather-stripped or other- <br />wise sealed. <br /> <br />PRACTICE #2 <br /> <br />-.------..-----------..--..--.-.---..-.----------------------------------------------------------------- <br /> <br />COMPLY WITH PRACTICE #1 AND THE FOllOWING: <br /> <br />606.1 <br /> <br />-------.------.-.--..---..-.--..--.---------------------------------------..--------------------------- <br /> <br />E:/;terior ll./alls <br />~I Floors <br /> <br />606.1 <br /> <br />Top plate penetrations sealed. Infiltration barrier <br />installed. Sole plate/floor joint caulked or sealed. <br /> <br />-------------------.---------------------------------------------------------------- <br /> <br />E:/;teriot" lIJalls <br />~I Ceilings <br /> <br />606. 1 <br /> <br />Penetrations, joints and cracks on interior surface <br />caulked, sealed or gasketed. <br /> <br />DuctWork <br /> <br />------------.----..----..---..----.--.-.--------------------------------------------------- <br /> <br />Ductwork in unconditioned space must be sealed. <br /> <br />606. 1 <br /> <br />------.--------.-----..-------.---..--------------.-----------------.----.--------------------------- <br /> <br />Fireplaces <br /> <br />606. 1 <br /> <br />Equipped with outside combustion air, doors and flue <br />dCl.mpet-s. <br /> <br />E:d'.alJst Fans <br /> <br />-------------------..--.-.-.-.--------------------------------..-.------------------------ <br /> <br />606. 1 <br /> <br />Equipped with dampers. Combustion devices see <br />606. 1 . A. 2. <br /> <br />..--.------.--.-.-..-..-..-.-..-.........-..-..-.-.-.-.-----.-..-------.----------.-.--.---.--.---.-.------------------------- <br /> <br />Combustion <br />Heating <br /> <br />606. 1 <br /> <br />Combustion space and water heating systems provided <br />with outside combustion air, except direct vent <br />appliances. <br /> <br />.--------------..-.-..-........----------------.-----------..-----..--.----.-.---.-----.-------------.-----------.-- <br /> <br />Water' HeatE:~rs <br /> <br />** OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by 2111 residences.) ** <br /> <br />612.1 <br /> <br />.--.-.-.----..---.-----.---.-..-------.--.-.-.----.-....-.--.-.---------.--------.------.---- <br /> <br />Comply with efficiency requirements in Table 6-11. <br />Switch or clearly marked circuit breaker (electric) <br />or cutoff (gas) must be provided. External or built- <br />in heat trap required. <br /> <br />----------------..-.-..---..-.-.-.---....------.--------------------.----..--------------------.------- <br /> <br />Swimmi ng POC) I s <br />~I Spas <br /> <br />612.1 <br /> <br />Spas and heated pools must have covers (except solar <br />heated). Non-commercial pools must have a pump timer. <br />Gas spa & pool heaters must have a minimum thermal <br />efficiency of 78 percent. <br /> <br />Shower Heads <br /> <br />.-.----.-..--.----------..-..-.-........----------------------.-.-----------------.-----------.-------------------.--.- <br /> <br />612.1 <br /> <br />Water flow must be restricted to no more than 3 gal- <br />lons per minute at 80 PSIG. <br /> <br />-...---------.-------.--..---.-------...----------------------------------------------------- <br /> <br />Air Distribution 610.1 <br />Systems <br /> <br />All ducts, fittings, mechanical equipment and plenum <br />chambers shall be mechanically attached, sealed, ins- <br />ulated and installed in accordance with the criteria <br />of Section 610. Ducts in unconditioned attics must <br />be insulated to a minimum of R-6. Air handlers shall <br />not he installed in attics unless in mechanical <br />closet. <br /> <br />HVAC Contt.'()l'3 <br /> <br />----------.-------.--------------------------..-----------.---------------- <br /> <br />607.1 <br /> <br />Separate readily accessible manual or automatic <br />thermostat for each system. <br /> <br />Ins IJ 1 at i () n <br /> <br />---.----.-------------------------------.------------------------------------ <br /> <br />604.1 <br />602.1 <br /> <br />Ceilings minimum R-19. Common Walls - Frame R-11 or <br />CBS R-3 both sides. Common ceiling & floors R-11. <br /> <br />-..-.---.--------..-------------------.-.------------------------------- <br />