Laserfiche WebLink
<br />Department of Community Affairs <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />FORM 600A-93 Residential Whole Building Performance Method A ~UTH <br />PROJECT NAME: Oak Crest Est~te :BUILDER: Gebhart Construction ~ ~ <br />AND ADDRESS: Lot #26~~3~ : PERMITTING : CLIMATE <br />Zephyrhills, FL 335:0FFICE: Zephyrhills :ZONE: 7:_: 8:_: 9:_: <br />Same :PERMIT NO.o-9'7c2.8 :JURISDICTION NO. ~//(POu <br /> <br />~ <br />, <br /> <br />OWNER: <br /> <br />L. New construction or addition <br />~. Single family detached or Multifamily attached <br />~. If Multifamily-No. of units <br />~. If Multifamily, is this a worst case (yes/no) <br />). Conditioned floor area (sq.ft.) <br />). Predominant eave overhang (ft.) <br />r Porch overhang length (ft.) <br />l. Glass area and type: <br />a. Clear Glass <br />b. Tint, film or solar screen <br />I. Floor type and insulation: <br />a. Slab on grade (R-value, perimeter) <br />.0.Net Wall type area and insulation: <br />a. Exterior: 1. Concrete (Insulation R-value) <br />b. Adjacent: 2. Wood frame (Insulation R-value) <br />.1.Ceiling type area and insulation: <br />a. Under attic (Insulation R-value) <br />,2.Air distribution systems <br />a. Ducts (Insulation + Location) <br />.3.Cooling system <br /> <br />,4.Heating System: <br /> <br />,5.Hot water system: <br /> <br />,6.Hot Water Credits: (HR-Heat Recovery, <br />DHP-Dedicated Heat Pump) <br />7.Infiltration practice: 1, 2 or 3 <br />8.HVAC Credits (CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, RB-Attic radiant <br />barrier, MZ-Multizone) <br />9.EPI (must not exceed 100 points) <br />a. Total As-Built points <br />b. Total Base points <br /> <br />1. <br />2. <br />3. <br />4. <br />5. 1716.00 <br />6. 2.00 <br />7. 13.00 <br />Single Pane <br />8a.228.0sqft <br />8b. O.Osqft <br /> <br />New Construction <br />Single-Fami.ly <br />o <br /> <br />SN: 7355 <br /> <br />~ <br />-vr <br />--::T <br />Double Pane <br />O.OOsqft v' <br />O.OOsqft ~ <br /> <br />9a.R= 4.00 , 180.60 ft V <br /> <br />10a-l R=11.00, 1277.80Sqft~ <br />10b-2 R=13.00, 166.40sqft~ <br /> <br />lla.R=30.00 , 1916.00sqft ~ <br /> <br />12a. R= 6.00, uncond <br />13. Type: Central A/C <br />SEER: 10 . 00 <br />14. Type: Heat Pump <br />HSPF: 7.60 <br />15. Type: Electric <br />EF: 0.97 <br /> <br />16. <br /> <br />17. <br />18. <br /> <br />3 <br />CF RB <br /> <br />v <br />v <br /> <br />v <br /> <br />v <br /> <br />v <br />v <br />V <br /> <br />v <br />(..... <br /> <br />v <br />V <br /> <br />------------------------------------------------------------------------------ <br /> <br />'-" <br /> <br />19. <br />19a. <br />19b. <br /> <br />71. 34 <br />23313.83 <br />32679.49 <br /> <br />------------------------------------------------------------------------------ <br /> <br />Hereby certify that the plans and <br />pecifications covered by this calcu- <br />ation are in compliance with the <br />lorida Ener~e. .2t __ ._ <br /> <br />REPARED BY: ~ ~~ <br />ATE: I) - --7:1<,- - <br /> <br />Review of the plans and specifications <br />covered by this calculation indicates <br />compliance with the Florida Energy <br />Code. Before construction is completed <br />this building will be inspected for <br />compliance in accordance with Section <br />553.908 F.S. <br /> <br />hereby certify that this building is <br />n compliance with Florida Energy <br />ode. <br /> <br /> <br />BUILDING OFFICIAL:~~ <br />DATE: /:2-/~-- . <br />