<br />. . <br />SUMMER POINT MULTIPLIERS (SPM) <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A.1 SUMMER OVERHANG FACTORS (SOFI FOR SINGLE AND DOUBLE PANE GLASS, <br />~r OH RATIO ,00-.11 ,12-,17 ,18-,26 ,27-,35 .36- .46 .47-,57 ,58- .70 ,71-,83 ,84-1.18 1.19-1,72 1.73-2.73 2.74+ <br />N 1.00 ,94 .91 .87 .83 ,79 ,75 ,72 ,69 ,62 ,56 ,50 <br />NElNW 1.00 .94 .91 .85 ,79 .72 ,68 ,63 ,58 ,50 ,40 ,36 <br />....a: Em 1,00 ,95 ,92 ,85 ,78 ,70 ,64 ,58 .52 ,42 .33 .26 <br />~o <br />~L SElSW 1.00 ,93 ,90 .81 .72 ,62 ,55 ,49 .42 ,33 ,27 .22 <br />S 1,00 ,91 ,87 ,77 ,67 ,57 ,50 .45 ,39 ,32 ,28 ,25 <br />nl-ll ~"I/'::TI-I* nft -1 ft 1% ft ?ft ~ft ~%ft ,111, ft 5'J?ft, IW,ft Qihft Uft ?nft... <br /> 'To select bv Overhann Lennth no nart of nlass shall be more than 8 It, below the overhano, <br /> <br />6A.2 WALL SUMMER POINT MULTIPLIERS SPM <br /> <br />FRAME <br /> <br />WOOD <br />EXT ADJ <br />6.4 2,2 <br />2,3 ,8 <br />1,9 .7 <br />1.7 ,6 <br />1,0 ,3 <br />,6 ,2 <br /> <br />R-VALUE <br />0-6,9 <br />7-10,9 <br />11-12.9 <br />13-18,9 <br />19-25,9 <br />26& U <br /> <br />STEEL <br />EXT ADJ <br />8,9 2,9 <br />4,1 1.3 <br />3,0 1.0 <br />2,8 0,9 <br />2.4 0,8 <br />1.3 0,4 <br /> <br /> <br />CONCRETE BLOCK1 <br />INT. INSULATION <br />NORMAL WT, <br />EXT ADJ <br />2,5 ,9 <br />1.4 ,7 <br />1.0 ,6 <br />.8 .4 <br />.4 ,3 <br />,2 ,2 <br />,1 ,1 <br /> <br /> <br />6A-S DOOR SUMMER POINT MULTIPLIERS 6A-4 CEILING SUMMER POINT MULTIPLIERS (SPMI <br />DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOF <br /> R-VALUE SPM R.VALUE SPM CEILING TYPE <br />WOOD 7,2 2.4 19-21.9 1.1 10-10,9 3,0 R-VALUE DROPPED EXPOSED <br /> 22-25,9 ,9 11-12,9 2.7 10-13,9 3,0 3,3 <br />INSULATED 4,8 1,6 26-29,9 ,7 13-18,9 2.4 14-20,9 2,0 2,1 <br /> 30-37,9 ,6 19-25,9 1.8 21 &IJo 1.4 1.3 <br /> 38 & Uo .4 26-29.9 1,1 <br /> ~n R. lJn nQ <br />6A-5 FLOOR SUMMER POINT MULTIPLIERS (SPM\ <br />SLAB-QN-GRADE :liI11~1: RAISED RAISED WOOD2 <br />EDGE INSULATION CONCRETE IF POST OR PIER STEM WALL wi UNDER ADJ~CENT <br /> CONSTRUCTION FLOOR INSULATION <br />R-VALUE SPM [i'i;;; R-VALUE SPM 'Lu R-V ALUE SPM SPM SPM <br />0-2,9 -31,9 iJL" 0-2,9 -1.0 0-6.9 0,9 -5.8 5.3 <br />3-4,9 -31,8 3-4,9 -1,7 IiU' 7-10,9 -1.1 -2.8 2,1 <br />5-6.9 -31,7 i!!' 5-6,9 -1.7 'F 11-18,9 -1,0 -2,2 1.8 <br />7 R. Iln _~1 ~ ,ii'! 7 R. lJn -17 1Q R.IJn -nQ _1 A 1n <br /> <br />SPM) <br /> <br />6A-6 INFILTRATION SUMMER POINT MULTIPLIERS (SPM) <br /> <br /> 6A-7 DUCT MULTIPLIERS IDM\ <br /> INFILTRATION PRACTICE SPM RETURN DUCTS RETURN DUCTS <br /> ISEE TABLE 6A-21\ R-V ALUE IN UNCONDITIONED SPACE IN CONDITIONED SPACE <br />PRACTICE #1 13,8 SUPPLY DUCTSIN 4,2-5,9 1.14 1.10 <br />PRACTICE #2 10,9 6,0-6.6 1,10 1,07 <br /> 7R UNCONDITIONED SPACE 6,7 & Un 1.09 1.06 <br /> SUPPLY DUCTS IN 4,2-5,9 1,10 1,00 <br /> CONDITIONED SPACE' 6,0-6,6 1.07 1.00 <br /> F. 7 R. lJn 1nF. 1 nn <br />6A-8 COOUNG SYSTEM MULTIPLIERS (CSMI <br />SYSTEM TYPE COOLING SYSTEM MULTIPLIERS (CSM\ <br />Central Units (SEER) Ratinn 7.5-7,9 8.0-8.4 8,5-8,8 8,9-9.4 9,5-9,9 10,0-10,4 10,5-10,9 11,0-11.4 11,5-11.9 12,0-12,4 <br />CSM .45 ,43 ,40 ,38 ,36 ,34 ,32 ,31 .30 .28 <br />PTAC & Room Units (EER) Ratina 12,5-12,9 13,0-13.4 13,5-13,9 14,0-14.4 14,5-14,9 15,0-15.4 15.5-15,9 16,0-1 €i.4 16,5-16,9 17,0-17,4 17,5 & Uo <br />CSM ,27 .26 ,25 ,24 ,24 .23 ,22 ,21 ,21 ,20 ,19 <br /> MINIMUMS: CENTRAL UNITS-AIR COOLED SPLIT SYSTEM 10,0 SEER, SINGLE PKG, 9,7 SEER, GROUND WATER HEAT PUMP 11,0 EER. PTAG-SEE TABLE 6,2 <br /> <br />6A-9 HOT WATER MULTIPLIERS (HWM\ <br />SYSTEM TYPE HOT WATER MUL TIPUERS (HWM <br />Electric Resistance EF ,80-,81 ,82-,83 ,84-,85 ,86-,87 ,88-,90 ,91-,93 ,94-,96 ,97 & Uo <br />HWM 3879 3785 3695 3609 3527 3411 3302 3200 <br />Natural Gas EF ,43-.47 I ,48-.49 I ,50-.51 ,52-,53 ,54-,55 .56- ,57 ,58- .59 ,60-,61 ,62-,63 ,64-,65 ,66 & Uo <br /> HWM 2974 I 2664 I 2558 2459 2368 2284 2205 2132 2063 1998 1938 <br />LP Gas HWM 3638 I 3259 I 3129 3009 2897 2794 2697 2607 2523 2444 2370 <br /> <br />, FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2,1 OF APPENDIX C, 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3,1 OF APPENDIX C, 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION, <br /> <br />,3, <br />