<br />MACY JACKSON AIR SYSTEMS <br />13914 NORTH FLORIDA AVENUE <br />TAMPA, FL 33613 <br /> <br />PROJECT: REESE RES, <br />CLIENT: BILL POE CONTRACTORS <br />DATE: 2-13-96 <br /> <br />RESIDENTIAL/LIGHT COMMERCIAL HVAC LOADS <br /> <br />DESIGNER: CHARLES JACKSON <br /> <br />CLIENT INFORMATION: <br /> <br />NAME; BILL POE CONTRACTORS <br />ADDRESS: <br />CITY, STATE: TAMPA,FLA, <br /> <br />TOTAL BUILDING LOADS: <br /> <br />------------------------------------------------------------------------------ <br /> <br />BLDG. LOAD AREA SEN. LAT. t SEN, : TOTA. <br />DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN <br />---------------------------------------------------------- ------------------- <br />1-C WIND. CLEAR GLASS METAL FRAME 204 11.074 0 5,688 5,688 <br />I 7 _ 1 PART R-II t R'.8 SHEATHING 7 '1-[ ""1-"","', 0 242 242 <br />"~ v ." V4..V '-"....1\; <br />14-1\ WALL 8"OR12" BLOCK NO INSU UNFIN 1,l9l 28,546 0 9,901 9,901 <br />10-E DOOR WOOD SOLID CORE & WOOD STM ryl 286 0 144 144 <br />"' <br />10-G DOOR WOOD PANEL 21 661 C 77rj 332 <br /> vvL <br />16-G CEILING R-30 INSULATION 2,005 3,111 0 2,9li 2,911 <br />22-A SLAB ON GRADE NO EDGE INSUL 188 7,158 0 0 <br /> ',) <br /> <br />------------------------------------------------------------------------------ <br /> <br />SUBTOTALS FOR STRUCTURE: 3,953 51,216 0 19,218 19,218 <br />PEOPLE ' c 0 3,450 4,500 7,950 <br /> u <br />APPLIANCES 0 0 3,200 0 3,200 <br />DUCTWORK 0 8,960 0 1,784 1,784 <br />INFIL TRATION W. CFf~: 234,4 S, CF,-: . 17 ') 0 12,118 4,781 2,578 7,359 <br />.....' ..L <br />V:NTILATION W,CFM: 0,0 S.CFM: 0.0 0 0 0 0 v <br /> <br />------------------------------------------------------------------------------- <br /> <br />SENSIBLE GAIN TOTAL <br />TEMP, SWING MULTIPLIER <br /> <br />28,080 <br />X 1.00 <br /> <br />BUILDING LOAD TOTALS <br /> <br />72,293 11,431 28,080 39,511 <br /> <br />------------------------------------------------------------------------------- <br /> <br />SUPPLY CFM AT 18 DEG DT: <br />SQUARE FT. OF ROOM AREA <br /> <br />1,418 <br />2,005 <br /> <br />C~M PER SQUARE FOOT: <br /> <br />0.7 C 7 <br /> <br />SQUARE FOOT PER TON: <br /> <br />608,944 <br /> <br />TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 72.293 MBH <br />TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 3.293 TONS <br /> <br />CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. <br />ALL COMPUTED RESULTS ARE ESTIMATES AS 8UILDING USE AND WEATHER MAY VARY, <br />BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS, <br />