<br />MACY JACKSON AIR SYSTEMS
<br />13914 NORTH FLORIDA AVENUE
<br />TAMPA, FL 33613
<br />
<br />PROJECT: REESE RES,
<br />CLIENT: BILL POE CONTRACTORS
<br />DATE: 2-13-96
<br />
<br />RESIDENTIAL/LIGHT COMMERCIAL HVAC LOADS
<br />
<br />DESIGNER: CHARLES JACKSON
<br />
<br />CLIENT INFORMATION:
<br />
<br />NAME; BILL POE CONTRACTORS
<br />ADDRESS:
<br />CITY, STATE: TAMPA,FLA,
<br />
<br />TOTAL BUILDING LOADS:
<br />
<br />------------------------------------------------------------------------------
<br />
<br />BLDG. LOAD AREA SEN. LAT. t SEN, : TOTA.
<br />DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN
<br />---------------------------------------------------------- -------------------
<br />1-C WIND. CLEAR GLASS METAL FRAME 204 11.074 0 5,688 5,688
<br />I 7 _ 1 PART R-II t R'.8 SHEATHING 7 '1-[ ""1-"","', 0 242 242
<br />"~ v ." V4..V '-"....1\;
<br />14-1\ WALL 8"OR12" BLOCK NO INSU UNFIN 1,l9l 28,546 0 9,901 9,901
<br />10-E DOOR WOOD SOLID CORE & WOOD STM ryl 286 0 144 144
<br />"'
<br />10-G DOOR WOOD PANEL 21 661 C 77rj 332
<br /> vvL
<br />16-G CEILING R-30 INSULATION 2,005 3,111 0 2,9li 2,911
<br />22-A SLAB ON GRADE NO EDGE INSUL 188 7,158 0 0
<br /> ',)
<br />
<br />------------------------------------------------------------------------------
<br />
<br />SUBTOTALS FOR STRUCTURE: 3,953 51,216 0 19,218 19,218
<br />PEOPLE ' c 0 3,450 4,500 7,950
<br /> u
<br />APPLIANCES 0 0 3,200 0 3,200
<br />DUCTWORK 0 8,960 0 1,784 1,784
<br />INFIL TRATION W. CFf~: 234,4 S, CF,-: . 17 ') 0 12,118 4,781 2,578 7,359
<br />.....' ..L
<br />V:NTILATION W,CFM: 0,0 S.CFM: 0.0 0 0 0 0 v
<br />
<br />-------------------------------------------------------------------------------
<br />
<br />SENSIBLE GAIN TOTAL
<br />TEMP, SWING MULTIPLIER
<br />
<br />28,080
<br />X 1.00
<br />
<br />BUILDING LOAD TOTALS
<br />
<br />72,293 11,431 28,080 39,511
<br />
<br />-------------------------------------------------------------------------------
<br />
<br />SUPPLY CFM AT 18 DEG DT:
<br />SQUARE FT. OF ROOM AREA
<br />
<br />1,418
<br />2,005
<br />
<br />C~M PER SQUARE FOOT:
<br />
<br />0.7 C 7
<br />
<br />SQUARE FOOT PER TON:
<br />
<br />608,944
<br />
<br />TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 72.293 MBH
<br />TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 3.293 TONS
<br />
<br />CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J.
<br />ALL COMPUTED RESULTS ARE ESTIMATES AS 8UILDING USE AND WEATHER MAY VARY,
<br />BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS,
<br />
|