<br />SUMMER POINT MULTIPLIERS (SPM) <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A.1 SUMMER OYER HANG FACTORS (SO 'J FOR SINGLE AND DOUBLE PANE GLASS. <br />~r OH RATIO ,00-,11 ,12-,17 .18-.26 ,27-,35 .36-,46 ,47-,57 ,58-,70 .71-,83 ,84-1,18 1.19-1.72 1,73-2.73 2.74+ <br />N 1.00 ,94 ,91 .87 ,83 ,79 .75 .72 .69 .62 ,56 ,50 <br />NE/NW 1,00 .94 ,91 ,85 ,79 .72 ,68 ,63 ,58 ,50 .40 ,36 <br />I-a: E/W 1.00 ,95 .92 ,85 .78 ,70 .64 .58 .52 ,42 ,33 ,26 <br />filo <br />ml SE/SW 1,00 .93 ,90 .81 .72 ,62 ,55 .49 ,42 ,33 ,27 .22 <br />S 1.00 ,91 .87 ,77 ,67 .57 ,50 .45 ,39 ,32 ,28 ,25 <br />IH' Oft 1 ft 1% ft 2ft 3ft 3% ft. 4%ft, 5%ft 6'hft, 9'h ft, 14ft, 20ft,+ <br /> 'To select bv Overhano Lenoth, no oart of olass shall be more than 8 ft, below the overhano, <br /> <br />6A.2 WALL SUMMER POINT MULTIPLIERS SPM <br /> <br />FRAME <br /> <br />WOOD <br />EXT ADJ <br />6,4 2,2 <br />2,3 .8 <br />1.9 .7 <br />1.7 ,6 <br />1,0 .3 <br />.6 ,2 <br /> <br />R.YALUE <br />0-6,9 <br />7-10,9 <br />11-12,9 <br />13-18.9 <br />19-25,9 <br />26& U <br /> <br />STEEL <br />EXT ADJ <br />8.9 2,9 <br />4,1 1.3 <br />3,0 1.0 <br />2.8 0,9 <br />2,4 0.8 <br />1.3 0,4 <br /> <br /> <br />CONCRETE BLOCK' <br />INT. INSULATION <br />NORMAL WT. <br />EXT ADJ <br />2.5 ,9 <br />1.4 .7 <br />1,0 ,6 <br />.8 .4 <br />.4 ,3 <br />,2 ,2 <br />.1 ,1 <br /> <br /> <br />6A-3 DOOR SUMMER POINT MULTIPLIERS 6A-4 CEILING SUMMER POINT MULTIPLIERS (SPM) <br />DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOF <br /> R.YALUE SPM R.YALUE SPM CEILING TYPE <br />WOOD 7,2 2.4 19-21.9 1,1 10-10,9 3.0 R.YALUE DROPPED EXPOSED <br /> 22-25,9 .9 11-12,9 2,7 10-13,9 3,0 3.3 <br />INSULATED 4,8 1.6 26-29,9 .7 13-18.9 2,4 14-20,9 2,0 2,1 <br /> 30-37,9 .6 19-25,9 1.8 21 & Uo 1.4 1,3 <br /> 38 & Uo ,4 26-29.9 1.1 <br /> 30 & Un 0,9 <br />6A.5 FLOOR SUMMER POINT MULTIPLIERS (SPM) <br />SLAB-ON-GRADE ':1/1 RAISED I:>> RAISED WOOIY <br />EDGE INSULATION CONCRETE POST OR PIER STEM WALL wI UNDER ADJ~CENT <br /> P,i CONSTRUCTION FLOOR INSULATION <br />R.YALUE SPM R.YALUE SPM Li.T R.Y ALUE SPM SPM SPM <br />0-2.9 -31.9 ii 0-2,9 -1.0 0-6.9 0.9 -5.8 5,3 <br />3-4,9 .31.8 3-4,9 -1.7 ii 7.10.9 -1.1 -:~,8 2,1 <br />5-6.9 -31.7 5-6,9 -1.7 11-18.9 -1.0 -2.2 1.8 <br />7 & Un -31.6 Hi 7& Un -1.7 19& Un -0,9 -1.8 1.0 <br /> <br />SPM) <br /> <br />6A-6 INFILTRATION SUMMER POINT MULTIPLIERS (SPM) <br /> <br /> 6A.7 DUCT MULTIPLIERS (DMl <br /> INFILTRATION PRACTICE SPM RETURN DUCTS RETURN DUCTS <br /> (SEE TABLE 6A-21) R.YALUE IN UNCONDITIONED SPACE IN CONDITIONED SPACE <br />PRACTICE #1 13,8 SUPPLY DUCTS IN 4,2-5.9 1,14 1,10 <br />PRACTICE #2 10,9 UNCONDITIONED SPACE 6.0-6,6 1.10 1.07 <br /> : #3 7,6 6.7 & Un 1,09 1.06 <br /> SUPPLY DUCTS IN 4,2.5,9 1.10 1.00 <br /> CONDITIONED SPACE' 6,0-6,6 1.07 1.00 <br /> 6.7 & Un 1.06 1.00 <br />6A.8 COOLING SYSTEM MULTIPLIERS (CSMl <br />SYSTEM TYPE COOLING SYSTEM MULTIPLIERS (CSM) <br />Central Units (SEER) RatinQ 7.5-7,9 8,0-8.4 8,5-8,8 8,9-9.4 9.5-9,9 10.0-10.4 10.5-10,9 11.0-11.4 11.5-11,9 12,0-12,4 <br />CSM ,45 .43 ,40 .38 .36 .34 .32 ,31 ,30 ,28 <br />PTAC & Room Units (EER) Ratina 12,5-12.9 13,0.13,4 13,5-13,9 14,0-14.4 14,5-14,9 15.0-15.4 15.5-15,9 16.0-16.4 16,5-16.9 17.0-17.4 17.5 & Up <br />CSM .27 ,26 .25 .24 ,24 ,23 ,22 ,21 ,21 .20 .19 <br /> MINIMUMS: CENTRAL UNITS-AIR COOLED SPLIT SYSTEM 10,0 SEER. SINGLE PKG, 9.7 SEER. GROUND WATER HEAT PUMP 11,0 EER. PTAG-SEE TABLE 6.2 <br /> <br />6A.9 HOT WATER MULTIPLIERS (HWM) <br />SYSTEM TYPE HOT WATER MULTIPLIERS (HWM <br />Electric Resistance EF .80..81 ,82-.83 ,84-,85 .86',87 ,88-,90 ,91-.93 .94-.96 ,97 & Up <br /> HWM 3879 3785 3695 3609 3527 3411 3302 3200 <br />Natural Gas EF .43-.47 I ,48-,49 .50-,51 ,52-,53 ,54-,55 .56-.57 ,58-.59 ,60-.61 ,62-.63 ,64-,65 ,66 & Up <br /> HWM 2974 I 2664 2558 2459 2368 2284 2205 2132 2063 1998 1938 <br />LP Gas HWM 3638 I 3259 3129 3009 2897 2794 2697 2607 2523 2444 2370 <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C, 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3,1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R.VALUE NECESSARY TO PREVENT CONDENSATION, <br /> <br />.3. <br />