<br />ADDITIONAL TABLES <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A-18 HEATING CREDIT MULTIPLIERS tHCM) <br />SYSTEM TYPE HEATING CREDIT MULTIPLIERS tHCM) <br />Attic Radiant Barrier HCM ,98 <br />Multizone HCM ,95 <br />Natural Gas AFUE ,68-,72 ,73-,77 ,78-,82 ,83-,87 ,88-.92 ,93 & Un <br /> HCM ,61 ,56 ,53 ,50 .47 ,44 <br />LP Gas HCM ,77 .72 ,67 ,63 .60 ,57 <br /> <br />6A-19 COOLING CREDIT MULTIPLIERS CCM) <br />SYSTEM TYPE COOLING CREDIT MUL TIPLlERSlCCM) <br />Ceilina Fans ,86' <br />Cross Ventilation ,95' 'Credit may be taken for only <br />Whole House Fan ,95' <br />Multizone ,95 one of these system types concu rrently, <br />Attic Radiant Barrier ,95 <br /> <br />Heat Recovery Unit <br /> <br /> <br /> <br />Dedicated Heat Pump <br /> <br />Solar <br /> <br />A HWM MUST BE USED IN CONJUNCTION WITH ALL HWCM, SEE TABLE 6A,9. EF MEANS ENERGY FACTOR. <br /> <br />6A.21 INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST (SEE SECTION 606) <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE #1 606,1 COMPLY WITH All INFilTRATION PRESCRIPTIVES, <br />Windows Maximum of 0.34 CFM oer linear foot of operable sash crack (includes slidina alass doors). <br />Exterior & Adiacent Doors Maximum of 0.5 CFM oer sa, ft. of door area' solid core wood panel insulated or alass doors onlv, <br />Exterior Joints & Cracks To be caulked. aasketed weatherstripped or otherwise sealed. <br />PRACTICE #2 606,1 COMPLY WITH #1 AND THE FOllOWING: <br />Exterior Walls and Floors Too olate penetrations sealed. Infiltration barrier installed. Sole plate/floor ioint caulked or sealed. <br />Exterior Walls & CeilinQs Penetrations, ioints and cracks on interior surface caulked sealed or aasketed. <br />Ductwork Ductwork in unconditioned snace must be sealed. <br />Fireolaces Eauipped with outside combustion air doors and flue damoers, <br />Exhaust Fans Eauiooed with damoers, Combustion devices see 606.1,A.2 <br />PRACTICE #3 606,1 COMPLY WITH PRACTICES #1 AND #2 AND THE FOllOWING: <br />Ceilinas Infiltration barrier installed. <br />Interior Walls Ton nenetrations sealed or ioints & cracks on interior walls caulked sealed or nasketed, <br />Recessed Liahts Sealed from conditioned & insulated from ventilated attic soaces. <br />Ductwork All ductwork located in conditioned space, <br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust <br /> by-products to outside, Combustion cooking appliances see section 606,1.A.3 <br /> <br />6A.22 OTHER PRESCRIPTIVE MEASURES tmust be met or exceeded by all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612,1 Comply with efficiency requirements in Table 6-11, Switch or clearly marked circuit breaker (electric) <br /> or cutoff (aas) must be orovided, External or built-in heat tran renuired. <br />Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated), Non-commercial pools must have <br /> a oumo timer. Gas soa & 0001 heaters must have a minimum thermal efficiencv of 78%, <br />Shower Heads 612,1 Water flow must be restricted to no more than 3 aallons per minute at 80 PSIG, <br />Air Distribution System 610,1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br /> sealed, insulated, and installed in accordance with the criteria of Section 61 O. Ducts in unconditioned <br /> attics must be insulated to a minimum of R-6. Air handlers shall not be installed in attics unless in <br /> mechanical closet. <br />HVAC Controls 607,1 Seoarate readilv accessible manual or automatic thermostat for each svstem, <br />Insulation 604,1, 602,1 Ceilinas-Min, R-19. Common walls-Frame R-11 or CBS R-3 both sides, Common ceilina & floors R-11, <br /> <br />.6, <br />