<br />. . <br /> <br />ADDITIONAL TABLES <br /> <br />CLIMATE ZONES 4.. 5 6 <br /> <br />6A-18 HEATING CREDIT MULTIPLIERS (HCM) <br />SYSTEM TYPE HEATING CREDIT MULTIPLIERS (HCMl <br />Attic Radiant Barrier HCM .98 <br />Multizone HCM .95 <br /> AFUE .68-.72 .73-.77 .78-.82 .83..87 .88..92 .93 & Uo <br />Natural Gas HCM .61 .56 .53 .50 .47 .44 <br />LP Gas HCM .77 .72 .67 .63 .60 .57 <br /> <br />6A-19 COOLING CREDIT MULTIPLIERS CCM) <br />SYSTEM TYPE COOLING CREDIT MULTIPLIERS (CCM) <br />Ceilina Fans .86' <br />Cross Ventilation .95' 'Credit may be taken for only <br />Whole House Fan .95' one of these system types concurrently. <br />Multizone .95 <br />Attic Radiant Barrier .95 <br /> <br /> <br />Heat Recovery Unit <br /> <br />Dedicated Heat Pump <br /> <br />Solar <br /> <br />6A-21 INFilTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST (SEE SECTION 606) <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE #1 606.1 COMPLY WITH All INFilTRATION PRESCRIPTIVES. <br />Windows Maximum of 0.34 CFM oer linear foot of ooerable sash crack (includes sliding glass doors), <br />Exterior & Adiacent Doors Maximum of 0.5 CFM per SQ. ft. of door area; solid core, wood oanel, insulated or Qlass doors onlv. <br />Exterior Joints & Cracks To be caulked, aasketed weatherstripped or otherwise sealed. <br />PRACTICE #2 606.1 COMPLY WITH #1 AND THE FOllOWING: <br />Exterior Walls and Floors Too olate oenetrations sealed. Infiltration barrier installed. Sole plate/floor ioint caulked or sealed. <br />Exterior Walls & Ceilinas Penetrations, ioints and cracks on interior surface caulked, sealed or gasketed. <br />Ductwork Ductwork in unconditioned space must be sealed. <br />Fireolaces Eauiooed with outside combustion air, doors, and flue dampers. <br />Exhaust Fans Eauiooed with damoers. Combustion devices see 606.1.A.2 <br />PRACTICE #3 606.1 COMPLY WITH PRACTICES #1 AND #2 AND THE FOllOWING: <br />Ceilinas Infiltration barrier installed. <br />Interior Walls 1 op penetrations sealed or ioints & cracks on interior walls caulked sealed or gasketed. <br />Recessed Liahts Sealed from conditioned & insulated from ventilated attic spaces. <br />Ductwork Ail ductwork located in conditioned space. <br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust <br /> by-products to outside. Combustion cooking appliances see section 606.1.A.3 <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-11. Switch or clearly marked circuit breaker (electric) <br /> or cutoff (aas) must be provided. External or built-in heat trao reauired. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heatedl. Non-commercial pools must have <br /> a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. <br />Shower Heads 612.1 Water flow must be restricted to no more than 3 gallons per minute at 80 PSIG. <br />Air Distribution System 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br /> sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned <br /> attics must be insulated to a minimum of R-6. Air handlers shall not be installed in attics unless in <br /> mechanical closet. <br />HV AC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. <br />Insulation 604.1, 602.1 Ceilinas-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. <br /> <br />-6- <br />