My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
96-5936
Zephyrhills
>
Building Department
>
Permits
>
1996
>
96-5936
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 2:50:36 PM
Creation date
7/19/2006 6:35:45 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
96-5936
Building Department - Name
RUSELL BROWN BUILD
Address
4708 SILVER OAKS
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />ADDITIONAL TABLES <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A.18 HEATING CREDIT MULTIPLIERS (HCM) <br /> SYSTEM TYPE !iEATING CREDIT MUL TIPLlER~~~_~____ <br />$fladiant Barrier HCM .98 ~-------_._-_.- <br />Mullizone HCM .95 __ -_'-0.__.__...--"...-- <br />Natural Gas AFUE .68-.72 .73-.77 .78-.82 I .83-.87 -------'~-.~g--- __ ,~H Up <br />HCM .61 .56 .53 I .50 .47 .44 <br /> -______ __ _u_ <br />LPGR!; HCM .77 .72 .67 I .63 .60 .57 <br /> <br />6A-19 COOLING CREDIT MULTIPLIERS CCM) <br />SYSTEM TYPE COOLING CREDIT MULTIPLIERS (CCM) -- ----.- <br />Ceiling Fans (86') <br />Cross Ventilalion ~gs-' 'Credit may be laken for only <br />Whole House Fan .95' one of these system types concurrently. <br />Multizone .95 <br />Attic Radiant Barrier .95 <br /> <br />Heat Recovery Unit <br /> <br /> <br /> <br />Dedicated Heat Pump <br /> <br />Solar <br /> <br />j; <br /> <br />!. <br /> <br />6A-21 INRLTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST (SEE SECTION 606) <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE '1 606.1 COMPLY WITH All INFilTRATION PRESCRIPTIVES. <br />Windows Maximum of 0.34 CFM per linear foot of operable sash crack (includes sliding glass doors). <br />Exterior & Adiacent Doors Maximum of 0.5 CFM per SQ. ft. of door area' solid core wood panel insulated or alass doors onlv. <br />Exterior Joints & Cracks To be caulked. aasketed weatherstriooed or otherwise sealed. <br />PRACTICE 12 606.1 COMPLY WITH #1 AND THE FOllOWING: <br />Exterior Walls and Floors Too olate penetrations sealed. Infiltration barrier installed. Sole platelfloor ioint caulked or sealed. <br />Exterior Walls & Ceilinas Penetrations ioints and cracks on interior surface caulked sealed or aasketed. <br />Ductwork Ductwork in unconditioned space must be sealed. <br />FireDlaces Eauipoed with outside combustion air doors and flue damoers. <br />Exhaust Fans Eauiooed with damoers. Combustion devices see 606.1.A.2 <br />PRACTICE j3 606.1 COMPLY WITH PRACTICES #1 AND #2 AND THE FOllOWING: <br />Ceilinos Infiltration barrier installed. <br />Interior Walls Top penetrations sealed or ioints & cracks on interior walls caulked sealed or aasketed. <br />Recessed Liahts Sealed from conditioned & insulated from ventilated attic soaces. <br />Ductwork All ductwork located in conditioned soace. <br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust <br /> by-products to outside. Combustion cooking appliances see section 606.1.A.3 <br /> <br />i <br />" <br /> <br />i1 <br />, <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-11. Switch or clearly marked circuit breaker (eleclric) <br /> or cutoff (aas) must be orovided. External or built-in heat trao required. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have <br /> a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. <br />Shower Heads 612.1 Water flow must be restricted to no more than 3 gallons per minute at 80 PSIG. <br />Air Distribution System 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br /> sealed, insulated, and installed in accordance with the criteria of Section 61 O. Ducts in unconditioned <br /> attics must be insulated to a minimum of R-6. Air handlers shall not be installed in attics unless in <br /> mechanical closet. <br />HV AC Conlrols 607.1 Separate readilv accessible manual or automatic thermostat for each svstem. <br />Insulation 604.1, 602.1 Ceilings-Min. R-19. Common walls-Frame R-ll or CBS R-3 both sides. Common ceilina & floors R-ll. <br /> <br />-6. <br />
The URL can be used to link to this page
Your browser does not support the video tag.