My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
96-5939
Zephyrhills
>
Building Department
>
Permits
>
1996
>
96-5939
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 2:50:33 PM
Creation date
7/19/2006 6:38:16 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
96-5939
Building Department - Name
RUSELL BROWN BUILD
Address
4765 SILVER OAKS
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />ADDITIONAL TABLES <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A-18 HEATING CREDIT MULTIPLIERS (HCM) <br /> SYSTEM TYPE .HEATI~G CREDIT MULT!~LIE~!l~~~~_~_~_ -_'0___.- <br />Allie Radianl Barrier HCM .98 -----~--- <br />Multizone HCM .95 ---------- <br />Natural Gas AFUE .68- .72 .73-.77 .78-.82 .83-.67 .88-.92 ~ -__,~~.e. Up ... <br />HCM .61 .56 .53 .50 .47 .44 <br /> _._~ --.--.-.---- <br />LP Gas HCM .77 .72 .67 .63 .60 .57 <br /> <br />6A-19 COOLING CREDIT MULTIPLIERS CCM) <br />SYSTEM TYPE COOLING CREDIT MULTIPLIERS (CCM) .----.....--.-". <br />CeiJino Fans (]6*) <br />Cross Ventilation 1Jb' 'Credit may be taken for only <br />Whole House Fan .95' one of these system types concurrently. <br />Multizone .95 <br />Allie Radiant Barrier .95 <br /> <br /> <br />Dedicated Heat Pump <br /> <br />ULIIalEBs.{Hw.cMl~__~_____ ._ <br />~-~-':-leatEumIL_...._. . <br /> <br />'1049 J- ~~S-.2\1J~~= <br /> <br />~L__ ___5.0 & Up. <br />----28 .21~__. __. ... .17. <br />A HWM MUST BE USED IN CONJUNCTION WITH AlL HWCM. SEE TABLE 6A-9. EF MEANS ENERGY FACTOR <br /> <br /> <br />Solar <br /> <br /> <br />6A-21 INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST (SEE SECTION 6061 <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE '1 606.1 COMPLY WITH All INFILTRATION PRESCRIPTIVES. <br />Windows Maximum of 0.34 CFM oer linear foot of ooerable sash crack (includes slidina alass doors). <br />Exterior & Adjacent Doors Maximum of 0.5 CFM oer sa. ft. of door area' solid core wood panel insulated or alass doors only. <br />Exterior Joints & Cracks To be caulked. aasketed, weatherstripped or otherwise sealed. <br />PRACTICE '2 606.1 COMPLY WITH #1 AND THE FOllOWING: <br />Exterior Walls and Floors Top plate penetrations sealed. Infiltration barrier installed. Sole olate'floor ioint caulked or sealed. <br />Exterior Walls & CeiJinos Penetrations, ioints and cracks on interior surface caulked sealed or gasketed. <br />Ductwork Ductwork in unconditioned space must be sealed. <br />FireDlaces Eauiooed with outside combustion air doors and flue damoers. <br />Exhaust Fans Eauiooed with damoers. Combustion devices see 606.1.A.2 <br />PRACTICE .3 606.1 COMPLY WITH PRACTICES #1 AND #2 AND THE FOllOWING: <br />Ceilinos Infiltration barrier installed. <br />Interior Walls Too oenetrations sealed or ioints & cracks on interior walls caulked sealed or gasketed. <br />Recessed Liohts Sealed from conditioned & insulated from ventilated attic soaces. <br />Ductwork All ductwork located in conditioned soace. <br />Combuslion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust <br /> by-products to outside. Combustion cooking appliances see section 606.1.A_3 <br /> <br />i: <br />! <br /> <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Waler Heaters 612.1 Comply with efficiency requirements in Table 6-11. Switch or clearly marked circuit breaker (electric) <br /> or cutoff (aas) must be orovided. External or built-in heat trao reauired. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools musl have <br /> a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. <br />Shower Heads 612.1 Water flow must be restricted to no more than 3 gallons oer minute at 80 PSIG. <br />Air Dislribution System 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br /> sealed, insulated, and installed in accordance with the criteria of Section 61 O. Ducts in unconditioned <br /> attics must be insulated to a minimum of R-6. Air handlers shall not be installed in attics unless in <br /> mechanical closet. . <br />HV AC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. <br />Insulation 604.1,602.1 Ceilings-Min. R-19. Common walls-Frame R-ll or CBS R-3 both sides. Common ceiling & floors R-ll. <br /> <br />-6. <br />
The URL can be used to link to this page
Your browser does not support the video tag.