Laserfiche WebLink
<br />Thomas F Devening PE <br />1364 Hillside Drive <br />Tarpon Springs, Florida 34689 <br />(813) 937-9146 home <br />(813) 429-8141 pager <br />(813) 942-0427 fax <br /> <br />July 3, 1996 <br /> <br />City of Zepher Hills <br />Department of Building Inspection <br />Zepher Hills, Florida <br /> <br />Subject: The Old Mayer's House <br />38632 5th Avenue <br />Zepher Hills <br /> <br />Dear Messrs: <br /> <br />On this day, an on-site field inspection was made by me or under my direction for the <br />purpose of determining the structural condition of the subject building. <br /> <br />There has been removed a section of wall approximately 6 feet in length due to termite <br />damage. It appears that all of the damaged wall has been removed and is ready for a <br />replacement wall to be constructed. <br /> <br />The existing foundation consists of piers and spread footings. On the East and West sides of <br />the building there has been some settlement of approximately 1" to 1-1/2", this settlement is <br />mainly noticeable due to the relative stability of the building center. There eltists a large <br />spread footing for a fireplace at the center of the building which settled at a lessor rate than <br />the perimeter of the building. <br /> <br />The remainder of the building was inspected and found to be in acceptable condition. <br /> <br />It is my professional determination that the subject building is in sound condition and does <br />retain its structural integrity and is suitable for occupation. <br /> <br /> <br />as F Devening <br />PE 41724 <br /> <br />FL96-715 <br />