<br />Builders (0' jJ err ( c> <br />Insulation Statement <br /> <br />CertainTeed t-l <br /> <br />InsulSafelll@ <br /> <br />Fiber Glass Insulation <br /> <br />Insul-Safe liP has been installed with the Thermal Performance - Attic Blowing Application <br /> <br />manufacturer's recommendations to pro- _ In accordance with the chart below, you must install the minimum number of bags per 1,000 sq. ft, <br />vide a va'ue of R /7' using ff bags of net area for each R-Value listed. <br />of insulation to cover ~ square feet of _ The maximum net coverage must not exceed that specified for each R-Value. <br />area at a minimum thickness of 2'~- The installed insulation must be at or above the specified minimum thickness for each R-Value, <br />inches - Failure to install the required minimum weight per sq, ft. of insulation at or above the minimum <br />. thickness will result in reduced R-Value, <br />~ _ This product should not be mixed with other blown insulations or the thermal claims will become <br />~, invalid. <br />Inst~Con;tor~ <br /> <br />coJf1pan;;me <br />9'-6 -7~ <br />Date <br /> <br />Builder (Sign) <br /> <br />Company Name <br /> <br />Date <br /> <br />Batts and Blanket <br />R-Value Insulation Thickness <br />R-38 10", 12" <br />A-3D 8'/4", 10" <br />A-22 6'/," <br />A-21 5'/," <br />A-19 6'/4' <br />A-15 3'j," <br />A-13 3'/," <br />A-11 3'/," <br />Complies with ASTM C 665 <br />Fiber g'ass batts or rolls have been <br />installed in accordance with the manu- <br />facturer's recommendation to provide <br />an R-value of _ in the ceiling, _ in <br />the exterior walls, _ in the floor <br />or crawl space perimeter. <br />Installer Contractor (Sign) <br />Company Name <br />Date <br />Builder (Sign) <br />Company Name <br />Date <br /> <br /> BAGS PER MAXIMUM MINIMUM WEIGHT- MINIMUM <br />R,VALUE 1000 sa, FT, sa. FT, PER BAG POUNDS PER sa, FT, THICKNESS <br />To obtain a Bags per Contents of bag Weight per sq, ft, of Should not be <br />thermal resistance 100 sq, ft, should not cover installed insulation should less than: <br />(R) of: of net area: more than: (sq, ft,) not be less than: (Ibs,) (inches) <br />R-60 42,6 23 1,064 23" <br />R-49 34,3 29 0,858 19 '{." <br />R-44 31,1 32 0,778 17'/.' <br />R-38 26,6 38 0,665 15 ';''' <br />R-30 20,8 48 0,521 12'12" <br />R-26 18,1 55 0.452 11" <br />R-22 15,0 67 0,374 9'/.' <br />R-19 13,2 76 0,330 8'/.' <br />R-13 9,0 111 0.225 5'/.' <br />R-11 7,4 136 0,184 4'/.' <br /> <br />A-Values are determined in accordance with ASTM C 687 and 518, Complies with ASTM C 764 <br />as Type I insulation, <br /> <br />"A" means resistance to heat flow, The higher the A-Value, the greter the insulating power, To <br />get the marked A-Value, it is essential that the insulation is installed properly, <br /> <br />DANGEA: AECESSED LIGHT FIXTUAES - TO PAEVENT OVEAHEATING, DO NOT <br />INSULATE ON TOP OA WITHIN 3" OF SUCH DEVICES, DOES NOT APPLY <br />TO TYPE IC LIGHT FIXTUAES OA TO FLUOAESCENT FIXTUAES WITH <br />THEAMALLY PAOTECTED BALLASTS. <br /> <br />Framing Adjustment <br /> <br />To compensate for framing members the number of bags pel' 1000 sq. ft. of net area should be <br />reduced as follows: <br /> <br /> Bags to Deduct / 1l1l1l1 sq, II, Bags to Deduct/1l1l1l1 sq, II, <br />Joist Size Joists 16"O.C. Joists 24''O,C, <br />2" x 4" 0.5 0.4 <br />2" x 6" 0.9 0.6 <br />2" x 8" 1,1 0.8 <br />2" x 10" 1.4 1,0 <br /> <br />Code No,30-24-092 <br /> <br />CertainTeed Corporation, P.O. Box 860, Valley Forge, PA 19482 <br /> <br />@l996 CertainTeed Corporation 4/96 <br />