<br />:5 <br /> <br />Table 2: Electrical Specifications - Four-Wire Function Card Application, Low Voltage AC or DC <br /> <br /> Voltage 2 Amp 10 Amp 1 Amp Power-On <br />Model Ranje I Standby Alarm Alarm Alarm su~rvlso~ LED <br />Number Stan by Current Current Contact3 Contact 3 ontact . (green) <br />609U11 8.5-33 VDC 50 uA 48mA 1 Form A , - - <br /> 24 VAC 1 Form C <br />609U31 8.5-33 VDC 9mA 57 mA 1 Form A - - y <br /> 24 V AC 1 Form C <br />609U12 17-33 VDC 50 uA 59 mA 1 Form A 2 Form C - - <br /> 24 V AC (11 mAl' (48 mA)' <br />609U32 17-33 VDC 9mA 68mA 1 Form A 2 Form C - y <br /> 24 V AC (20mA)' (57 mAl 1 <br />f--, <br />609U33 17-33 VDC 17 mA 65mA 1 Form A - 1 Form A Y <br /> 24 V AC 1 Form C <br />609U14 17-33 VDC 8mA 67 mA 1 Form A 2 Form C 1 Form A - <br /> 24 V AC (19 mAl' (56 mAl' <br />609U34 17-33 VDC 17 mA 76mA 1 Form A 2 Form C 1 Form A Y <br /> 24 V AC (28mA)' (65 mAl , <br /> <br />1, The 10 Ampere contact relay of the 609U 12. 609U14. 609U32 and 609U34 function cards can be field programmed to be normally operated. and <br />to release on alarm. sensing head removal or power loss. by moving jumper J1 0 from pin P8 to pin Pl, If the relay is programmed in such a manner, <br />the standby current @24 VDCN AC is increased by 10 milliamperes, and the alarm current is reduced by 10 milliamperes, as shown in parenthesis, <br /> <br />2, The Form A supervisory contact is closed with power applied, <br /> <br />3, Relay contact rating shown are for a resistive load at 30 VDC or 120 VAC maximum, <br /> <br />Table 3: Electrical Specifications - Four-Wire Function Card Application, Line Voltage AC or Low Voltage AC or DC <br /> <br />Model Voltage Standby 2Amp 10 Amp 1 Amp <br />Ran9Je Alarm Alarm Alarm SU&ervlso~ <br />Number Stan by Current Current Contact3 Contact3 ontact2. <br />609U21 102-132 VAC or 15 mA 20mA 1 Form A - - <br /> 17-33 VDC/24 VAC' I 1 Form C <br />609U22 102-132 VAC or 15 mA 20 mA 1 Form A 2 Form C - <br /> 17 -33 VDC/24 V AC 1 <br />609U23 102-132 VAC or 15mA 20m A 1 Form A - 1 Form A <br /> 17 -33 VDC/24 V AC' 1 Form C <br />609U24 102-132 VAC or 15 mA 20 mA 1 Form A 2 Form C 1 Form A <br /> 17 -33 VDC/24 V AC' <br />609U25 187-242 VAC 5mA 10 mA 1 Form A 2 Form C - <br /> <br />1, For Models 609U21. 609U22. 609U23. and 609U24, when converted in the field for low voltage operation the electrical specifications of the simi/iar low <br />voltage card in Table 2 apply. For example, if you convert a Model609U21 for low vol/age operation use the specifications of a 609U31. For a convened <br />609U22. use the specifications of 609U32. etc, <br /> <br />2, The Form A supervisory contact is closed with power applied, <br /> <br />3, Relay contact ratings shown are for a resistive load at 30 VDC or 120 VAC maximum, <br /> <br />Sampling Tubes <br /> <br />A pressure differential pulls air in through the inlet sampling tube <br />and into the sampling chamber, then sends it back out into the duct <br />through the outlet sampling tube, <br /> <br /> <br />Each duct detector housing is equipped with 5,25 inch inlet and <br />exhaust sampling tubes, The ends of these tubes are cut at a <br />450angle, The inlet tube faces upstream and the exhaust tube <br />faces downstream to ensure airflow through the housing, The <br />tubes provide the means of obtaining a sample of air from the duct. <br /> <br />Although this product is approved for use without additional <br />extension sampling tubes, optional lubes may be required by the <br />authority having jurisdiction, OPTIONAL sampling tubes are <br />available in several lengths, <br />