My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
96-6066
Zephyrhills
>
Building Department
>
Permits
>
1996
>
96-6066
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 2:49:57 PM
Creation date
7/19/2006 9:41:13 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
96-6066
Building Department - Name
BROWN CONST
Address
4729 SILVER CR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />ADDITIONAL TABLES <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A-18 HEATING CREDIT MULTIPLIERS (HCM) <br /> SYSTEM TYPE HEATING CREDIT MULTIPLIERS iliCM) <br />Allie Radiant Barrier HCM .98 ------,.-.------ ... <br />Multizone HCM .95 --,,- <br />Natural Gas AFUE .68-.72 .73-.77 .78-.82 .83-.87_ ~:~ I---'~~ ~ LJP <br />HCM .61 .56 .53 .50 .47 .44 <br /> __m____...__ <br />LPGll!: HCM .77 .72 .67 .63 .60 .57 <br /> <br />6A-19 COOLING CREDIT MULTIPLIERS CCM) <br /> SYSTEM TYPE COOLING CREDIT MULTIPLIERS (CCM) ____.______n.___-.-_ <br />Ceilina Fans r.86*) <br />Cross Ventilation ~~* 'Credit may be taken for only <br />Whole House Fan .95' one of Ihese system types concurrently. <br />Multizone .95 <br />Allie Radiant Barrier .95 <br /> <br /> <br />Heat Recovery Unit <br /> <br /> <br />LWATfR.cREDII ULD~UERSlI:fWCM)___.._____... <br />Air Condiliooer_JieatPJ.llD,O_____ <br /> <br />~~_.3,5&UIL.... <br />---29_ __~2S____ <br />...4,(}:4,9... ..._5.Q &-.U.p______ <br />.2.1~.._._ J 7.. <br />A HWM MUST BE USED IN CONJUNCTION WITH All HWCM. SEE TABLE 6A-9. EF MEANS ENERGY FACTOR. <br /> <br /> <br />Dedicated Heat Pump <br /> <br />Solar <br /> <br /> <br />6A-21 "INAL TRA TION REDUCTION PRACTICE COMPLIANCE CHECKLIST (SEE SEcnON 606) <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE #1 606.1 COMPLY WITH All INFll TRA TION PRESCRIPTIVES. <br />Windows Maximum of 0.34 CFM oer linear foot of ooerable sash crack iincludes slidina alass doors): <br />Exterior & Adiacent Doors Maximum of 0.5 CFM per sa. ft. of door area' solid core wood oanel insulated or alass doors only. <br />Exterior Joints & Cracks To be caulked aasketed weatherstripped or otherwise sealed. <br />PRACTICE #2 606.1 COMPLY WITH #1 AND THE FOllOWING: <br />Exterior Walls and Floors Too olate oenetrations sealed. Infiltration barrier installed. Sole olatelfloor ioint caulked or sealed. <br />Exterior Walls & Ceilinas Penetrations ioints and cracks on interior surface caulked sealed or aasketed. <br />Ductwork Ductwork in unconditioned soace must be sealed. <br />Fireolaces Eauiooed with outside combustion air doors. and flue dampers. <br />Exhaust Fans Eauiooed with damoers. Combustion devices see 606.1.A.2 <br />PRACTICE #3 606.1 COMPLY WITH PRACTICES #1 AND #2 AND THE FOLLOWING: <br />Ceilinns Infiltration barrier installed. <br />Interior Walls Too nenetrations sealed or ioints & cracks on interior walls caulked sealed or aasketed. <br />Recessed Liahts Sealed from conditioned & insulated from ventilated attic spaces. <br />Ductwork All ductwork located in conditioned soace. <br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust <br /> by-products to outside. Combustion cooking appliances see section 606. 1.A.3 <br /> <br />'I <br />. <br />I <br />.' <br />ij <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.) <br />COMPONENTS SECTION REQUIREMENTS < , CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-11. Switch or clearly marked circuit breaker (electric) <br /> or cutoff (aas) must be orovided. External or built-in heat trao reauired. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have <br /> a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. <br />Shower Heads 612.1 Water flow must be restricted to no more than 3 aallons Der minute at 80 PSIG. <br />Air Distribution System 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br /> sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned <br /> attics must be insulated to a minimum of R-6. Air handlers shall not be installed in attics unless in <br /> mechanical closet. <br />HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. <br />Insulation 604.1, 602.1 Ceilinas-Min. R-19. Common walls-Frame R-ll orCBS R-3 both sides. Common ceilina & floors R-ll. <br /> <br />-6- <br />
The URL can be used to link to this page
Your browser does not support the video tag.