<br />, ~ ..' -," <br /> <br />. ADDITIONAL TABLES <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A.18 HEATING CREDIT MULTIPLIERS tHCM) <br />SYSTEM TYPE HEATING CREDIT MULTIPLIERS (HCM) <br />Attic Radiant Barrier HCM .98 <br />Multizone HCM .95 <br /> AFUE .68-.72 .73- .77 .78-.82 .83-.87 .88-.92 .93 & Up <br />Natural Gas HCM ,61 .56 .53 .50 .47 ,44 <br />LP Gas HCM .77 .72 .67 .63 .60 .57 <br /> <br />6A-19 COOLING CREDIT MULTIPLIERS CCM) I <br />SYSTEM TYPE COOLING CREDIT MULTIPLIERS tCCM) <br />Ceilino Fans .86* <br />Cross Ventilation .95* *Credit may be taken for only <br />Whole House Fan .95* one of these system types concurrently. <br />Multizone .95 <br />Attic Radiant Barrier .95 <br /> <br /> <br />Heat Recovery Unit <br /> <br />With <br />HW M <br />F <br />HWCM <br />EF <br /> <br />Dedicated Heat Pump <br /> <br />Solar <br /> <br />6A-21 INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST tSEE SECTION 606\ <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE #1 606.1 COMPLY WITH ALL INFILTRATION PRESCRIPTIVES. <br />Windows Maximum of 0.34 CFM per linear foot of operable sash crack (includes slidinQ glass doors). <br />Exterior & Adjacent Doors Maximum of 0.5 CFM per sa. ft. of door area; solid core, wood panel, insulated or Qlass doors onlv. <br />Exterior Joints & Cracks To be caulked Qasketed weatherstripped or otherwise sealed. <br />PRACTICE #2 606.1 COMPLY WITH #1 AND THE FOLLOWING: <br />Exterior Walls and Floors Top plate penetrations sealed. Infiltration barrier installed. Sole plate/floor ioint caulked or sealed. <br />Exterior Walls & Ceilinos Penetrations, joints and cracks on interior surface caulked, sealed or aasketed. <br />Ductwork Ductwork in unconditioned soace must be sealed. <br />Fireolaces Equipped with outside combustion air doors, and flue damoers. <br />Exhaust Fans Eauipped with dampers. Combustion devices see 606.1.A.2 <br />PRACTICE #3 606,1 COMPLY WITH PRACTICES #1 AND #2 AND THE FOLLOWING: <br />Ceilinos Infiltration barrier installed. <br />Interior Walls 100 penetrations sealed or ioints & cracks on interior walls caulked sealed or aasketed. <br />Recessed Liohts Sealed from conditioned & insulated from ventilated attic soaces. <br />Ductwork All ductwork located in conditioned space. <br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust <br /> by-products to outside. Combustion cooking appliances see section 606.1.A.3 <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES tmust be met or exceeded bv all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-11. Switch or clearly marked circuit breaker (electric) <br /> or cutoff (aas) must be provided. External or built-in heat trap required. <br />Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have <br /> a pump timer. Gas soa & 0001 heaters must have a minimum thermal efficiency of 78%, <br />Shower Heads 612.1 Water flow must be restricted to no more than 3 Qallons per minute at 80 PSIG. <br />Air Distribution System 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br /> sealed, insulated, and installed in accordance with the criteria of Section 61 O. Ducts in unconditioned <br /> attics must be insulated to a minimum of R-6, Air handlers shall not be installed in attics unless in <br /> mechanical closet. <br />HV AC Controls 607,1 Separate readily accessible manual or automatic thermostat for each system. <br />Insulation 604.1, 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. Common ceilina & floors R-11. <br /> <br />-6- <br />