Laserfiche WebLink
<br />" WINTER POINT MULTIPLIERS (WPM) <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A-10 WINTER OVERHANG FACTORS (WOF) <br />J OH RATIO I ,00-,11 ,12-,17 1 .18-,26 ,27-.35 I .36-,46 I .47-,57 ,58-.70 / ,71-,83 .84-1.18 11,19-1.72/1.73-2.73 I 2,74+ <br /> SINGLE PANE GLASS <br />N 1.00 1,03 1.05 1.08 1.10 1.13 1.15 1,18 1.20 1,24 1.29 1.34 <br />NE/NW 1.00 1.07 1,10 1.15 1.20 1.25 1.30 1.35 1,39 1.50 1.59 1,67 <br />EJW 1.00 .71 .57 ,19 -.20 -.65 -1.05 -1.48 -2,03 -3,01 -4,06 -5,04 <br />SE/SW 1,00 ,93 .90 ,80 ,68 .54 .39 ,22 ,05 -.33 -.71 -1.01 <br />l- S 1.00 .95 ,92 .83 .70 .54 .36 ,13 -.13 -.70 -,98 -1,09 <br />oa: <br />~[ DOUBLE PANE GLASS <br />N 1.00 1.05 1.07 1.11 1.14 1,18 1.21 1.24 1,28 1,34 1.40 1.47 <br />NE/NW 1,00 1.11 1.16 1,24 1.32 1.41 1,48 1.56 1,63 1.80 1.94 2.08 <br />EJW 1.00 .88 ,82 .66 ,50 .31 .15 -,03 -,26 -.66 -1.10 -1.50 <br />SE/SW 1.00 .95 ,92 .85 .76 ,65 .54 .41 ,28 -,01 -,30 -,52 <br />S 1.00 ,96 .94 ,87 .78 .65 ,51 .33 ,13 -,30 -.51 -.60 <br />OH LENGTH' Oft, 1 ft, l%ft, 2ft, 3 ft, 3'12 ft. 4%ft, 5%ft, 6% ft. 9% ft. 14ft. 20ft.+ <br /> 'TO SELECT BY OVERHANG LENGTH, NO PART OF GLASS SHALL BE MORE THAN 8 FT. BELOW THE OVERHANG. <br /> <br />6A-11 WALL WINTER POINT MULTIPLIERS WPM <br /> <br />FRAME <br /> <br />WOOD <br />EXT ADJ <br />6.8 5.3 <br />2,5 2.1 <br />2,0 1.8 <br />1.8 1.6 <br />1.1 1.0 <br />,7 .7 <br /> <br />R-VALUE <br />0-6,9 <br />7-10,9 <br />11-12.9 <br />13-18,9 <br />19-25,9 <br />26& U <br /> <br />STEEL <br />EXT ADJ <br />9.4 6,7 <br />4.4 3,3 <br />3.3 2.6 <br />3,0 2.4 <br />2.6 2.2 <br />1.4 1,2 <br /> <br /> <br />CONCRETE BLOCK1 <br />INT, INSULATION <br />NORMAL WT. <br />EXT ADJ <br />6,0 3.1 <br />3,8 2,3 <br />2.9 1.9 <br />2,3 1,5 <br />1.5 1.1 <br />,8 .7 <br />.5 .5 <br /> <br /> <br />6A-12 DOOR WINTER POINT MULTIPLIERS 6A-13 CEILING WINTER POINT MULTIPLIERS (WPM} <br />DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOF <br /> R-VALUE WPM R-VALUE WPM CEILING TYPE <br />WOOD 7,6 5,9 19-21.9 1.0 10-10.9 1.8 R-VALUE DROPPED EXPOSED <br /> 22-25,9 .9 11-12,9 1.6 10-13,9 1.2 1.3 <br />INSULATED 5,1 4,0 26-29.9 .7 13-18,9 1.5 14-20,9 ,7 .7 <br /> 30-37,9 .6 19-25.9 1.1 21 & Up .4 .3 <br /> 38 & Up ,4 26-29,9 ,6 <br /> 3011. Un .4 <br />6A-14 FLOOR WINTER POINT MULTIPLIERS (WPM} <br />SLAB-DN-GRADE :: RAISED Tn RAISED WOOD2 <br />EDGE INSULATION ;; CONCRETE POST OR PIER STEM WALL wI UNDER ADJACENT <br /> CONSTRUCTION FLOOR INSULATION <br />R-VALUE WPM R-VALUE WPM R-VALUE WPM WPM WPM <br />0-2.9 2,5 nTn 0-2.9 4,0 0-6.9 7.9 1,8 5.3 <br />3-4,9 -1.7 Vi 3-4,9 1.8 7-10.9 2,1 .7 2,1 <br />5-6,9 -2.4 liii 5-6.9 1.1 " 11-18,9 1.5 .5 1.8 <br />7 P.IJn -? 7 In 711.lJn R Un HllI.LJn 9 .3 1.0 <br /> <br />WPM) <br /> <br />6A-15 INFIL TRA nON WINTER POINT MULTIPLIERS (WPM) <br /> <br /> 6A-16 DUCT MUL nPLlERS (OM} <br />INFILTRATION PRACTICE WPM RETURN DUCTS RETURN DUCTS <br /> (SEE TABLE 6A-21) R-V ALUE IN UNCONDITIONED SPACE IN CONDITIONED SPACE <br />PRACTICE #1 6.2 SUPPLY DUCTS IN 4,2-5.9 1.14 1.10 <br />PRACTICE #2 4,1 6.0-6.6 1.10 1.07 <br /> 2.2 UNCONDITIONED SPACE 6.7 & UD 1,09 1.06 <br /> SUPPLY DUCTS IN 4,2-5,9 1.10 1.00 <br /> CONDITIONED SPACE' 6.0-6.6 1.07 1.00 <br /> fl711.lJn 100 100 <br />6A-17 HEATING SYSTEM MULTIPLIERS (HSMl <br />SYSTEM TYPE HEATING SYSTEM MULTIPLIERS (HSM) <br />Central Heat HSPF 6,40-6,79 6,80-6,89 6.90-7,39 7.40-7,89 7,90-8,39 8,40-8,89 8,9-9,39 9.4-9.89 <br />Pump Units HSM ,53 ,50 .49 .46 ,43 .41 ,38 .36 <br /> HSPF 9,90-10.39 10.40-10,89 10.90-11.39 11.40-11,89 11.90-12,39 12,40 & up <br /> HSM ,34 .33 .31 .30 .29 ,28 <br />PTHP COP 2,50-2,69 2.70-2.89 2,90-3.09 3.10-3.29 3.30-3.49 3,50-3.69 3.70-3.89 3.90-4.19 <br /> HSM .40 .37 .34 .32 .30 .29 ,27 .26 <br />Electric StriD 1.0 <br />Gas & LP Gas 1,0 (See Table 6A-18 for Credit Multinlier\ <br /> MINIMUMS: CENTRAL UNITS-AIR SOURCE SPLIT SYSTEM 6.8 HSPF. SINGLE PKG. 6.6 HSPF, WATER SOURCE 3.8 COP. GROUND WATER SOURCE 3.4 COP. PTHP SEE TABLES 6-6 TO 6-8. <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-V ALUE NECESSARY TO PREVENT CONDENSATION. <br /> <br />-5- <br />