Laserfiche WebLink
<br />7 <br />,r~ <br /> <br />c.~lr <br /> <br />f1;;~ .?~:,tl/ <br /> <br />,",' <br /> <br />~ <br /> <br />FIELD DENSITY - PERCENTAGE OF COMPACTION REPORT <br />Florida Testing & Environmental, Inc. <br /> <br />SOIL TESTING <br /> <br />P.O. BOX 5603 Lakeland, Florida 33807 . Telephone (941)648-1000 <br />. Fax (941)648-4799 <br /> <br />Project: House Pads - Zephyrhills Date: 11-21-97 <br /> Silver Oaks Estates <br /> Lab No: 1-D <br />Client: Bill Poe Contractors <br /> P,O. Box 465 Job No: 97-2999 <br /> Trilby I FL 33593 <br /> Technician: Chet Deimling <br />Contractor: Bill Poe Contractors Weather Conditions: Partly Cloudy <br /> <br />ASTM - D 2922 IN PLACE FIELD DENSITIES - DATE MADE 11-20-97 T I <br /> H N <br /> I C <br /> In-Situ In-Pia Lab Compaction C H <br />Test Moisture Dry Max. Percent K E <br />Location of Test N S <br />No. Percent Density Density E <br /> PCF PCF Attained Required S <br /> S <br /> House Pad <br />1 Northeast Corner Of Pad 13.2 108.8 109.7 99 90 - <br />2 Northwest Corner Of Pad 12,5 108,5 109.7 99 90 - <br />3 Southeast Corner Of Pad 12.9 109.2 109.7 100 90 - <br />4 Southwest Corner Of Pad 13.1 108.7 109.7 99 90 - <br /> <br />The Percentage of compaction for the in-place density tests are based on laboratory Moisture Density Relations Tests As Follows: <br /> <br />LAB NO: 1 P <br /> <br />MAXIMUM DRY DENSITY: 109.7 Pcf OPTIMUM MOISTURE CONTENT: 12,3% <br /> <br />REPORT DISTRIBUTION: 1: Addressee <br />1: Pasco County Inspections <br /> <br />