Laserfiche WebLink
<br />SERIAL # '2334 <br />* ResmanuJ(c) * 11-06-1996 <br />WHOLE HOUSE <br />HEAT GAIN / HEAT LOSS CALCULATION USING FLA/RES(c) DATA FILES <br />(BASED ON A.C.C.A. MANUAL J - SEVENTH EDITION (c) 1986 by A.C.C.A.) <br /> <br />------------------------------------------------------------------------------- <br /> <br />PROJECT <br />ADDRESS : <br />CITY : <br />OWNER : <br />BLDG CONTR <br />HVAC CONTR <br />Cond FIr Area: 960 SF * GLASS/SF RATIO = 10.6% * House Faces: East <br />* Climatic Conditions & Design Conditions * <br /> <br />Geographical Location : Florida <br /> <br />---------------------------------------------------------------------------- <br /> <br />Lakeland <br /> <br />-------------------------------------------------------------.--------------- <br /> <br />North Latitude / Elevation <br />Outdoor Winter Dry Bulb <br />Indoor Winter Dry Bulb <br />Winter (Actual) Temp.Diff. <br />Winter Temp. Diff. (wTd) <br />Outdoor Summer Dry Bulb <br />Outdoor Summer Wet Bulb <br />Outdoor Summer Hum. Ratio Gr/Lb <br />Indoor Summer Relaltive Hum. <br />Indoor Summer Design Gr/Lb. <br />Indoor Summer Dry Bulb <br />Indoor Summer Wet Bulb <br />Summer Daily Range <br />Summer (Actual) Temp.Diff. <br />Summer (User Sel) Temp.Diff. (sTd) <br /> <br />28 Deg. / 214 Ft. Above Sea Level <br />41 Deg. F <br />70 Deg. F <br />29 Deg. F <br />40 Deg. F <br />91 Deg. F <br />76 Deg. F <br />113 <br />50% <br />51 <br />75 Deg. F <br />62.3 Deg. F @ 64 Gr/Lb <br />17 Deg. F M <br />16 Deg. F <br />20 Deg. F <br /> <br />------------------------------------ --------------------------------------- <br /> <br />SUBTOTAL <br /> <br />* HEATING SUMMARY * MF960E .DAT * COOLING SUMMARY * <br /> <br />19188.06 STRUCTURE SENSIBLE <br />MECH.VENT- 0 Cfm <br />SENS. + MECH.VENT <br />TEMP.SWING @ 3 DEG. <br />OCCUPANT/APPLIANCE <br />959.40 DUCT GAIN <br />20147.46 TOTAL SENSIBLE <br />TOTAL LATENT <br /> <br />DUCT LOSS <br />TOTAL LOSS/BTUH <br /> <br />:SENSIBLE + LATENT <br />20% OVERSIZE FACTOR 4029.49 :20% SENS.OVRSZE FTR: <br />ACTUAL + 20% OVERSIZE: 24176.95 :SENS. + 20% OVERSIZE: <br /> <br />* EQUIPMENT SELECTION * <br /> <br />EQT MANUF GOODMAN <br />HTG INP/BTUH 22800 <br />SENSIBLE BTUH 17100 <br />TONAGE 1.9 (S)EER 10 <br />NOTES: <br /> <br />CU MOD # CPE24-1 <br />HTG OUTP/BTUH 22800 <br />LATENT BTUH 5700 <br />CLG CFM 800 <br /> <br />AHU MOD # A24-05 <br />AFUE/HSPF 7 TYPE HP <br />TTL CLG BTUH 22800 <br />HTG CFM.800 <br /> <br />9925.391 <br />0.00 <br />9925.391 <br />1. 00 <br />2400.00 <br />1232.54 <br />13557.93 <br />2476.77 <br /> <br />16034.70 <br />2711.59 <br />16269.52 <br />