Laserfiche WebLink
<br />Form 4'00A.,.\9,4:; :/J.\,; <br /> <br />Whole Building Performance Method for Commercial Buildings <br /> <br />..' -' : ,~ <br /> <br />ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />Florida Department of Community Affairs <br /> <br />"';:."IIJA <br /> <br />..,. . <br /> <br />FLA/COM-94 Version 2.1A <br /> <br />PROJECT NAME-F.M.C. - UROLOGY <br />ADDRESS: Z~YRHILLS, FLORIDA <br /> <br />OWNER: JLO~~tA ~~ 4.tINIC <br />AGENT: <br /> <br />BUILDING TYPE: _Institutional (Health) <br />CONSTRUCTION CONDITION: Existing Building <br />DESIGN COMPLETION: _Renovation <br />CONDITIONED FLOOR AREA: _5640 <br />MAX. TONNAGE OF EQUIPMENT PER SYSTEM: ____ <br /> <br />-a.. <br /> <br />PERMITTING OFFICE: <br />_Zephyrhi lIs <br />CLIMATE ZONE: _4 <br />PERM I T NO: bJ.Jy _611600 <br />JURISDICTION NO:_611600 <br /> <br />r '. .'~:' ~; .. <br /> <br />.' t. ,~.- ~~.' <br /> <br />or <br /> <br />NUMBER OF ZONES: 1 <br /> <br />COMPLIANCE CALCULATION: <br /> <br />METHOD A <br /> <br />----------------- <br /> <br />A. WHOLE BUILDING <br /> <br />PRESCRIPTIVE REQUIREMENTS: <br /> <br />LIGHTING <br />LIGHTING CONTROL REQUIREMENTS <br />i HVAC EQUIPMENT <br />COOLING EQUIPMENT <br />1. EER <br />IPLV <br />HEATING EQUIPMENT <br />1. Et <br />AIR DISTRIBUTION SYSTEM INSULATION <br />1. With Insulated Roof <br />WATER HEATING EQUIPMENT <br />1. EF <br />PIPING INSULATION REQUIREMENTS <br />1. Circulating <br /> <br />.COMPLIANCE CERTIFICATION:~ <br /> <br />I hereby certify that the plans and <br />specifications cover9d by this calcu- <br />lation are in compliance with the <br />Florida En~ygy ~fficie~~code. <br />PREPAR:::D 8"':._ :r71!t'Vt/l ~~1/ <br />DATE: /Z/. - __ <br />. _--L.~ / . <br /> <br />I hereby certify that this building is <br />in compliance with the Florida Energy <br />Efficiency Code. <br />OWNER/AGENT: <br />DATE: <br /> <br />23 <br /> <br />,'., ~, <br /> <br />DESIGN <br /> <br />CRITERIA <br /> <br />RESULT, i <br /> <br />......----...... ", <br /> <br />69.51 <br /> <br />100.00 <br /> <br />PASSES <br /> <br />PASSES <br /> <br />10.00 <br />12.00 <br /> <br />8.50 <br />7.50 <br /> <br />PASSES <br />PASSES . <br /> <br />1.00 <br />LEVEL <br />15.00 <br /> <br />N/A <br />.. <br /> <br />6.00 <br /> <br />PASSE So-. . <br /> <br />20.00 <br /> <br />0.89 <br /> <br />PASSES <br /> <br />1.00 <br /> <br />0.32 <br /> <br />PASSES, ,~ <br /> <br />"I C j <br /> <br />.. <br /> <br />Review of the plans and specifica~'" <br />tions covered by this calculation <br />indicates compl lance with the .'. , " . <br />Florida Energy Efficiency Code. '. ~,1>',: <br />Before construction is completed. <br />this building will be inspected ";",: <br />for compliance in accordance with, . ; <br />Section 553.908, Florida Statutes. ..j ,"'''1 <br />BUILDING OFFICIAL:, " " <br />DATE: <br /> <br />. -. ...I~ <br /> <br />l';f <br /> <br />t.:... . <br /> <br />" <br /> <br />... <br />