Laserfiche WebLink
<br />401.------GLAZING--ZONE <br />Elevation Type <br /> <br />Adjacent <br /> <br />Commercial <br /> <br />402.------WALLS--ZONE <br />Elevation Type <br /> <br />BUILDING INFORMATION COMPLIANCE <br />CHECK <br /> <br />1------------------------------------------------v- <br /> <br />U SC VLT Shading Area (Sqft) <br /> <br />o 1.0 0 None 0 <br />Total Glass Area in Zone 1 = 0 <br />Total Glass Area = 0 <br /> <br />1------------------------------------------------ <br /> <br />U Added R Gross (Sqft) <br /> <br />--------- -------------------------------- ----- ------- ----------- <br /> <br />North <br />West <br />East <br />South <br /> <br />Metal <br />Metal <br />Metal <br />Metal <br /> <br />Curtain <br />Curtain <br />Curtain <br />Curtain <br /> <br />403.------DOORS--ZONE <br />Elevation Type <br /> <br />Without Air 0.091 0 1800 <br />Without Air 0.091 0 1675 <br />Without Air 0.091 0 2300 <br />Without Air 0.091 0 0 <br />Total Wall Area in Zone 1 = 5775 <br />Total Gross Wall Area = 5775 <br /> <br />1-----------------------------------------___~--- <br /> <br />U Area (Sqft) <br /> <br />Wall: <br />Wall: <br />Wall: <br />Wall: <br /> <br />Adjacent <br /> <br />1-3/8 Wood <br /> <br />--------- ------------------------------------------ ----- ---------- <br /> <br />404.------ROOFS--ZONE <br />Type <br /> <br />Door-Panel with 7/16" panels 0.57 40 <br />Total Door Area in Zone 1 = 40 <br />Total Door Area = 40 <br /> <br />1-----------------------------------------_______ <br /> <br />Color U Added R Area (Sqft) <br /> <br />Metal/insulated <br /> <br />------------------------------------ ------ ----- ------- ---------- <br /> <br />405.------FLOORS-ZONE <br />Type <br /> <br />Light .091 0 6624 <br />Total Roof Area in Zone 1 = 6624 <br />Total Roof Area = 6624 <br /> <br />1-----------------------------------_____________ <br /> <br />R Area (Sqft) <br /> <br />------------------------------------------------ <br /> <br />Slab on Grade/Uninsulated 0 6624 <br />Total Floor Area in Zone 1 = 6624 <br />Total Floor Area = 6624 <br /> <br />406.------INFILTRATION--------------------______________________________ <br /> <br />I CHECK <br />Infiltration Criteria in 406.1.ABC.1 have been met. <br /> <br />407.------COOLING SySTEMS--------------------------_____________________ <br /> <br />Type No Efficiency IPLV Tons <br /> <br />---------------------------- <br /> <br />---------- ----- -------------- <br /> <br />1. Air Cooled 1 10.5 11.5 20.00 <br /> <br />408.------HEATING SySTEMS-------------------------______________________ <br /> <br />Type No Efficiency BTU/hr <br /> <br />-------------------------------- <br /> <br />---------- -------------- <br /> <br />1. Electric Resistance 1 1.0 9200 <br /> <br />409.------VENTILATION---------------____________________________________ <br /> <br />I CHECK <br />Ventilation Criteria in 409.1.ABC.1 have been met. <br />410.-----AIR DISTRIBUTION SySTEM--------------------------______________ <br />AHU Type Duct Location R-value <br /> <br />----------------------------------- ---------------------- ------- <br /> <br />1. Packaged Constant Volume <br />411.-----PUMPS AND PIPING-ZONE <br />Type <br /> <br />Conditioned Space 6.2 <br /> <br />1---------------------------____________ <br /> <br />R-value/in Diameter Thickness <br /> <br />------------------------ <br /> <br />---------- -------- --------- <br /> <br />412.-----WATER HEATING SYSTEMS-ZONE 1--------------------------________ <br />