Laserfiche WebLink
<br />200 Photoelectric Smoke Detector <br /> <br />~ <br /> <br />By H...yw.1I PruI.clllM1 S.rvlces <br /> <br />Honeyw{.n <br /> <br />Features <br /> <br />Selectable Alarm Current- (2-Wire Model) <br />Allows a choice of 25 ma, 50. ma, or 90. ma, <br /> <br />135F Heat Sensor Option- <br />Activates alarm when temperature at detector reaches 135F <br />Specify HD option when ordering, <br /> <br />Separate Detector and Base Design- <br />Permits the same detector to be used with both 2- and 4-wire <br />bases, Features quick-disconnect ease and positive-lock <br />assembly stability, <br /> <br />Universal Mounting- <br />Allows connection to single and double gang outlet and switch <br />boxes, as well as standard 4" square and octagonal type <br />boxes, May also be connected to surface mounted Wiremold <br />type raceways, <br /> <br />Dust Proof Protection- <br />Sealed electronics permit drafty "plenum" ceiling applications <br />without concern for nuisance alarms due to "pull-through" dust <br />caused by pressure differentials, <br /> <br />Tamper Protection- <br />No concern about forgetting to replace the detector. In/Out wiring <br />results in a fail-safe trouble signal with detector removal. <br /> <br />Vandal Protection- <br />Detector securely latches to base with two point tie-down, <br /> <br />Specifications <br /> <br />Models- <br />20.0. Detector only (requires base), <br />2o.o.HD Detector with 1350F Heat Sensor (requires base), <br />MB2o.o.-2W Base, 2-Wire, <br />MB2o.o.-4W Base, 4-Wire. <br />2o.o.-2W 20.0. with MB2o.o.-2W Base, <br />2o.o.-4W 20.0. with MB2o.o.-4W Base. <br />2o.o.HD-2W 2o.o.HD with MB2o.o.-2W Base. <br />2o.o.HD-4W 2o.o.HO with MB2o.o.-4W Base. <br /> <br />Accessories- <br />EOL2o.o. End-Of-Line Module for 4 Wire Systems, <br />T2o.o. Ceiling Disconnect Tool <br /> <br />Environmental Limits- <br />Temperature: +320F to +12o.oF (+o.oC to +490C) Tested, +320F <br />to +1o.o.oF (+o.oC to +380C) Normal Operating, <br />Humidity: 0. to 95% RH; Non-condensing, Withstands Humidity <br />Shock testing, <br /> <br />Electrical Requirements- <br />Voltage: 10. to 27 VOC <br /> <br />Maximum RMS Ripple: Less than 25% of DC Input <br />Standby Current: 25 micro-amps (u a), Max. <br />Alarm Current: 2-Wire = Selectable 25, 50. or 90. ma depending <br />on panel used, 4-Wire = 25 ma @ 12 VDC 36 ma @ 24 <br />VDC <br />Start-Up Current: 20.0. micro-amps (u a), max, for 0.3 sec, (after <br />initial power applied,) <br /> <br />Sensitivity- <br />Factory calibrated for 3% gray smoke obscuration, <br /> <br />Alarm Condition- <br />2-Wire: SCR switch, Selectable alarm current <br />4-Wire: Mechanical relay Dry contacts rated 30. VDC, 2A, <br />resistive load, <br /> <br />Infrared Source Pulse Format- <br />30.0. micro-second wide pulse every two seconds, At 3% <br />threshold obscuration, pulse speed increases four times (4X) , <br />Alarm Initiated after 5 consecutive pulses if still above <br />threshold, Automatic pulse count reset if obscuration drops <br />below 3% threshold before alarm initiated, <br /> <br />Power and Alarm Indicators- <br />Two annunciator LEOs located close to the base on opposite <br />sides of the detector are standard, LED1 flashes briefly every <br />two seconds to verify normal operation of internal infrared <br />source, LED2 normally OFF, but latches ON in the event of an <br />alarm; standard reset with power interrupt <br /> <br />Remote Alarm Indicator- <br />Optional remote alarm LED circuit available. Up to 10.0. ma <br />allowed in remote circuit using 2-Wire base; 80. ma with 4-Wire <br />base, <br /> <br />Full Function Test- <br />Individual detector alarm using a magnet in conjunction with a <br />built-in internal reed switch, <br />Multiple detector alarm using optional N.o switch installed <br />between terminal 'I" and ground at any base, <br /> <br />Radio Frequency Interference- <br />No alarm or set-up on critical frequencies in the range from 26 to <br />90.0. MHz using a 10. Watt transmitter located 4ft, (1,2 m) from <br />the unit or attached wiring under test <br /> <br />Terminal Designations- <br />2-Wire Class B, 4-Wire Class B, <br /> <br />Approvals- <br />Underwriters Laboratories (U,L,) Listed <br />State of California Fire Marshall (CFM) Approved <br /> <br />Honeywell <br /> <br />HELPING YOU CONTROL YOUR WORLD <br /> <br />@ Honeywell, lnc 1989 <br /> <br />PROTECTION SERVICES DIVISION <br /> <br />Honeywell Plaza <br />Minneapolis, Minnesota 55408 <br /> <br />I n Canada <br />100 Montcalm Blvd N <br />Candiac, Quebec <br />J5R 1 B7 <br /> <br />Providing nationwide U L listed central station alarm service <br /> <br />56-32144/89 Printed In U,S.A <br />