<br /><elroTTER <br /> <br />FOR SMALL PIPE <br /> <br />VSR-SF <br />VANE TYPE W~.TERFLOW <br />ALARM SWITCH WITH RETARD <br /> <br />Potter Electric Signal Company <br />2081 Craig Rd.,/P.O. Box 28480 <br />St. Louis, Mo. 63146"4161 <br />(314)878"4321/(800)325-3936 <br /> <br />Potter Electric Signal & Mfg. L TO <br />1967 Leslie Street <br />Don Mills, Ontario, Canada M3B2M3 <br />(416)441"1833 <br /> <br /> <br />STK. NO. 1113000 <br />U.S. PAT. NO. 3921989, CANADIAN PAT. NO. 1009680 <br />OTHER PATENTS PENDING. <br /> <br />UL, ULC. CSFM LISTED & NYMEA ACCEPTED <br /> <br />Service Pressure: Up to 250 PSI <br /> <br />Minimum Flow Rate for Alarm: 10 GPM <br /> <br />Maximum Surge: 18 FPS <br /> <br />Enclosure: Cast Aluminum, red enamel finish, <br />Cover held in place with lam per resistant screws <br /> <br />Contact Ralings: Two sets of S,P,D,T, (Form C) <br />10 Amp, @ 125/250 VAC <br />2 Amp, @ 0-30 VDC <br /> <br />Conduit Entrances: Two Knockouts provided for 1/2" condUit <br /> <br />Usage: Listed Plastic, Copper and Schedule 40 Iron Pipe. <br />Fits pipe sizes - 1", 1 1/4", & 1 1/2" <br />Note: 8 paddles are fumished with each unit, one for each pipe size of <br />threaded or sweat TEE, one for 1" CPVC, and one for <br />1 1/2" polybutylene (CTS-Copper tubing size). <br /> <br />Environmental Specifications: Suilable for indoor or outdoor use with <br />factory installed gasket and die-C<lst aluminum housing, <br />NEMA 4 Rated Enclosure - use with appropriate conduit fil1ing, <br />Temperature Range - 40' F/120' F (4S C/49- C) <br /> <br />Caution: ThiS device IS not intended for applications in explosive environ- <br />ments, <br /> <br />Service Use: <br />Automatic Sprinkler <br />One or Two Family Dwelling <br />Residential Occupancy up to 4 Stories <br />National Fire Alann Code <br /> <br />NFPA-13 <br />NFPA-13D <br />NFPA-13R <br />NFPA-72 <br /> <br />Optional: Cover Tamper Switch, order Stk, No, 0090018 <br /> <br />The Model VSR-SF IS a vane type waterflow switch for use on wet sprinkler <br />systems thaI use "', 1 1/4', or 1 1/2" pipe size. The unit may also be used <br />as a sectional waterflow detector on large systems. <br /> <br />The unit contains two single pole double throw snap action switches and an <br />adjustable pneumatic retard. The switches are actuated when a flow of 10 <br />gallons per minute or more occurs downstream of the device. The flow <br />condition must exist for a period of time neeessary to overcome the selected <br />retard period, <br /> <br />INSTALLA nON: These devices may be mounted in a horizontal orvertiCilI <br />pipe, On horizontal pipe they should be Installed on the top side of the pipe <br />where they will be accessible The uni1s should not be installed wilhin 6. of <br />a valve, drain or fitting which changes the direction of the waterflow, The <br />uni1 has a " NPT bushing for threading into a non corrosive "TEE", See <br />figure 2 for proper 'lEE' size. type and installation, <br /> <br />Screw the device into the "TEE' fil1lng as shown In Fig 2 Care must be <br />taken to properly orient the deVice for the drrect,on of waterllow <br /> <br />The vane must nol rub the inside of the "TEE" or bind in any way, The stem <br />should move freely when operated by hand, <br />The device can also be used in copper or plastic pipe installations with the <br />proper adapters so that the specified "TEE" fil1ing may be installed on lhe <br />pipe run. <br /> <br />INSPECTION AND TESTING: Check the operation of the unit by opening <br />the "Inspection Test Valve" at the end of the sprinkler line or the drain and <br />test connection, if an Inspectors Test Valve is not provided. <br /> <br />If there are no provisions fortesting the operation of the flow detection deVice <br />on the system, appliC<ltion ofthe VSR-SF is not recommended or advisable <br /> <br />The frequency of the inspection and testing and its associated proteel/ve <br />monitoring system should be in accordance with the applicuble NFPA <br />Codes and Standards und/or authority having jurisdiction (munufucturer <br />recommends quarterly or more frequently). <br /> <br />CAUTION: There are 8 paddles furnished with each unit. These paddles have raised lettering that shows the pipe <br />size and type of "TEE" that they are to be used with, The proper paddle must be used. The screw that holds the paddle <br />must be securely tightened. <br /> <br />PRINTED IN USA <br /> <br />MKT. #8800003 - REV G <br />MFG. #5400802 - 3,94 <br /> <br />PAGE 1 OF2 <br />