My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
97-6551
Zephyrhills
>
Building Department
>
Permits
>
1997
>
97-6551
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 3:06:02 PM
Creation date
8/2/2006 1:41:42 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
97-6551
Building Department - Name
FL MED CLINIC
Address
38100 - 38117 MARKET SQ
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Intelliguard Control Centers <br /> <br /> <br />Control Centers <br /> <br />540 CONTROL CENTER <br />The 540 Control Center is a 4-wire keypad/display unit used with the <br />Intelliguard 5700, 5800, 5900, and 5924 security systems. It features a <br />10-digit keypad, five function keys, a 16-character English language <br />display, and a built-in speaker that emits several distinct warning tones. <br />The 540 function keys include: <br />ALL ON/OFF key anns and disanns all areas for which a <br />user has authority. <br />ENTER key brings the user to the first command on the <br />command list. <br />NEXT key allows the user to view a list of bypassed and faulted <br />points in a disanned area. This key also provides navigation through <br />the tailored command list. <br />PREVIOUS key penn its the user to see the status of all bypassed <br />and faulted points in an area that is disanned. When viewing the <br />tailored command list, this key shows the user the previously <br />available command. <br />CLEAR key silences all trouble and alann tones for the local control <br />center. This key also allows the user to scroll through a list of trouble <br />and alanns. <br /> <br />541 FIRE CONTROL CENTER <br />The 541 Fire Control Center provides simple control of fire protection <br />and does not require a passcode for operation. The 541 function keys <br />include: <br />ACKNOWLEDGE key silences the control center sounder (not fire <br />audibles) and releases the display to scrolI through alann events. <br />SILENCE key silences any indicating devices (fire horns, burglary <br />bells, etc.), as weilas releases the scrolling alann display. <br />RESET key re-initiates all sensors and clears the alann memory. If <br />this key is pushed before ACKNOWLEDGE or SILENCE, it will act <br />as the SILENCE key. <br /> <br />542 FIRE ANNUNCIATOR <br />The 542 Fire Annunciator is a remote display for fire alann events that <br />allows local authorities to easily view fire alann conditions. The 542 <br />features a display and sounder and is assigned to a specific area. There <br />are no alann control capabilities with this control center. The words <br />FIRE ALARM are prominently displayed on the keypad. All alann <br />events from the control center's assigned area are shown. <br />NEXT key steps through multiple alann displays, <br /> <br />550 LED CONTROL CENTER <br />THE 550 LED Control Center is an economical control center that <br />provides control over a single area with simple LED annunciation. The <br />550 is designed for areas with less than nine points of protection and <br />moderate security operations, such as a cash office or stock room. The <br />550 may be used for a combination of burglary, fire, or other point type <br />monitoring. The display consists of LEDs, which indicate anned status, <br />point status, and power. The sounder is a piezo device. <br /> <br />The 550 function keys include: <br />ALL ON/OFF key anns and disanns only the local area. <br />ENTER key silences alarms other than burglary alanns. <br />PERIMETER key Perimeter Anns or Disanns the area. <br />WATCH key turns the watch mode on and off. <br />RESET key reinitiates all sensors and clears the alann memory <br />for the area. <br /> <br />Specifications <br /> <br />Dimensions <br />. Control Centers: 8.5" x 4.5" x 0.9" <br /> <br />Voltage Input <br />. Nominal 12 VDC supplied by the Intelliguard control/ <br />communicator <br /> <br />Current Required <br /> <br />540,541, and 542 Control Centers <br />· Idle: 104mA <br />. Maximum: 206mA, with annunciation and warning tone on <br /> <br />550 LED Control Center <br />. Idle: 20mA <br />. Maximum 75mA, with annunciation and warning tone on <br /> <br />Wiring Primary <br />. Four-wire cable supplies Data In, Data Out, + 12VDC, and <br />Common <br />. Maximum data loop resistance: 24Q <br /> <br />Colors <br />. Fire Engine Red <br />. Soft White <br /> <br />Display <br /> <br />540,541, and 542 Control Centers <br />. l6-character vacuum fluorescent display <br />. l4-segment unit characters <br />. Soft blue color <br /> <br />550 LED Control Center <br />. 8 point LED display <br />. I power LED <br />. I command LED <br />. 3 ann status LEDs <br /> <br />Environmental <br />. Operating Specifications: 32-122 Y2F (0-50Y2C) <br />. Relative Humidity: 5 to 85%@ 86Y2F (30Y2C) <br /> <br />Approvals <br /> <br />. UL for Central Station, Police Connect and Local Burglary <br />. UL for NFPA 71 and 72 (Chapters 6 & 8) Fire <br />. California State Fire Marshal <br />. New York City-MEA <br /> <br />Honeywell <br /> <br />Helping You Control Your World <br /> <br />Home and Building Control <br />Honeywell Inc. <br />Honeywell Plaza <br />P.O. Box 524 <br />Minneapolis, MN 55440-0524 <br /> <br />In Canada: <br />8 Place du Commerce <br />Nuns' Island Verdun Quebec <br />Canada H3E I N3 <br /> <br />56-50096/94 . Printed in USA. Providing nationwide U.L listed central station alarm service 1-800-328-5111 <br /> <br />~ 50% Total Recovered Fiber <br />\:l:I 10% Post Coosumer Fiber <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.