My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
97-6594
Zephyrhills
>
Building Department
>
Permits
>
1997
>
97-6594
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 3:05:56 PM
Creation date
8/2/2006 2:14:29 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
97-6594
Building Department - Name
RYMAN CONSTRUCTION
Address
37400 CORNWALL DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Department of Community Affairs <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />FORM 6DDA-93 Residential Whole Building Performance Method A CENTRAL <br />PROJECT NAME: Model 1643 Face NOl:tl BUILDER: Ryman Construction Inc. .' <br />AND ADDRESS: 51400 ~~ ~. PERMITTINGelr-f pr CLIMATE /" <br />V .~ OFFICE:;C.cmrA'tY/tL5 ZONE: 41~ 5/_1 6/_1 <br />OWNER: ~.. PERMIT NO,_... JURISDICTION NO.t,.//tf-OO <br />t, S'9'1h-J CK <br />1. New construction or addition 1. New Construction __.__ <br />2. Single family detached or Multifamily attached 2. Single-Family <br />3. If MUltifamilY-No. of units 3. 0 <br />4. If MUltifamily, is this a worst case (yes/no) 4. <br />5. Conditioned floor area (sq.ft.) 5. 1090.00 <br />6. Predominant eave overhang (ft.) 6. 2.00 <br />7. Porch overhang length (ft.) 7. 4.75 <br />8. Glass area and type: Single Pane <br />a. Clear Glass 8a. O.Osqft <br />b. Tint, film or solar screen 8b. O.Osqft <br />9. Floor type and insulation: <br />a. Slab on grade (R-value, perimeter) <br />10.Net Wall type area and inSUlation: <br />a. Exterior: 2. Wood frame (Insulation R-value) lOa-2 R-ll.OO, 843,70sqft____ <br />b. Adjacent: 2. Wood frame (Insulation R-value) 10b-2 R=ll,OO, 211.40sqft____ <br />11.Ceiling type area and inSUlation: <br />a. Under attic (Insulation R-value) <br />12.Air distribution systems <br />a. Ducts (Insulation + Location) <br />13.Cooling system <br /> <br />SN: 8132 <br /> <br />Double Pane <br />O.OOsqft <br />166.30sqft <br /> <br />9a.R= 0.00 " 155.00 ft <br /> <br />11a.R=22.00 , 1090.00sqft____ <br /> <br />14.Heating System: <br /> <br />12a. R= 6.00, uncond <br />13. Type: Central A/C <br />EER: 9.30 <br />14. Type: Heat Pump <br />HSPF: 6.60 <br />15. Type: Electric <br />EF: 0,,88 <br /> <br />15.Hot water system: <br /> <br />16.Hot Water Credits: (HR-Heat Recovery, <br />DHP-Dedicated Heat Pump) <br />17. Infiltration practice: 1, 2 or 3 <br />18.HVAC Credits (CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, RB-Attic radiant <br />barrier, MZ-Multizone) <br />19.EPI (must not exceed 100 points) <br />a. Total AS-Built points <br />b. Total Base points <br /> <br />16. <br /> <br />17. <br />18. <br /> <br />2 <br /> <br />---------------------------------------------------------------.---------------- <br /> <br />---------------------------------------------------------------'---------------- <br /> <br />19. <br />19a. <br />19b. <br /> <br />89.00 <br />19213.48 <br />21587.71 <br /> <br />I Hereby certify that the plans and <br />specifications covered by this calcu- <br />lation are in compliance with the <br />Plorida Ener;,; ~_ _ <br /> <br />?REPARED BY:~ <br />)ATE: 2 -~5 - '1 <br /> <br />Review of the plans and specifications <br />covered by this calculation indicates <br />compliance with the Florida Energy <br />Code. Before construction is completed <br />this bUilding will be inspected for <br />compliance in accordance with Section <br />553.908 F.S. <br /> <br />: hereby certify that this bUilding is <br />n compliance with the Florida Energy <br />~ode. c.~ <br /> <br /> <br />:;~~i~~/~~ ~- <br /> <br />BUILDIN~F~AL:~~ <br />DATE: Qt n <br /> <br />~ <br />
The URL can be used to link to this page
Your browser does not support the video tag.