My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
97-6655
Zephyrhills
>
Building Department
>
Permits
>
1997
>
97-6655
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 3:05:50 PM
Creation date
8/3/2006 6:11:15 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
97-6655
Building Department - Name
BILL POE CONST
Address
6731 NORTHLAKE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />ADDITIONAL TABLES <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A-18 HEATING CREDIT MULTIPLIERS (HCM) <br />SYSTEM TYPE HEATING CREDIT MULTIPLIERS (HCM) <br />Allie Radiant Barrier HCM .98 <br />Multizone HCM .95 <br />Natural Gas AFUE .68-.72 .73-.77 .78- .82 .83-.87 .88-.92 .93 & UP <br />HCM .61 .56 .53 .50 .47 .44 <br />LP Gas HCM .77 .72 .67 .63 .60 ,57 <br /> <br />6A-19 COOLING CREDIT MULTIPLIERS CCM) <br />SYSTEM TYPE COOLING CREDIT MULTIPLIERS (CCM) <br />Ceilina Fans .86' <br />Cross Ventilation .95' 'Credit may be taken for only <br />Whole House Fan .95' one of these system types concurrently. <br />Multizone .95 <br />Allie Radiant Barrier .95 <br /> <br /> <br />Heat Recovery Unit <br /> <br /> <br /> <br />Dedicated Heat Pump <br /> <br />Solar <br /> <br />A HWM MUST BE USED IN CONJUNCTION WITH ALL HWCM. SEE TABLE 6A-9. EF MEANS ENERGY FACTOR. <br /> <br />6A-21 INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST (SEE SECTION 606) <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE #1 606.1 COMPLY WITH All INFilTRATION PRESCRIPTIVES. <br />Windows Maximum of 0.34 CFM oer linear foot of operable sash crack (includes slidina alass doors\. <br />Exterior & Adiacent Doors Maximum of 0.5 CFM oer sa. ft. of door area; solid core wood oanel, insulated or alass doors onlv. <br />Exterior Joints & Cracks To be caulked, oasketed, weatherstripped or otherwise sealed. <br />PRACTICE #2 606.1 COMPLY WITH #1 AND THE FOllOWING: <br />Exterior Walls and Floors Top plate penetrations sealed. Infiltration barrier installed. Sole plate/floor ioint caulked or sealed. <br />Exterior Walls & Ceilinas Penetrations, ioints and cracks on interior surface caulked, sealed or oasketed. <br />Ductwork Ductwork in unconditioned space must be sealed. <br />Fireolaces Eauipped with outside combustion air, doors and flue damoers. <br />Exhaust Fans Eauipped with dampers. Combustion devices see 606.1.A.2 <br />PRACTICE #3 606.1 COMPLY WITH PRACTICES #1 AND #2 AND THE FOllOWING: <br />Ceilinas Infiltration barrier installed. <br />Interior Walls Top penetrations sealed or ioints & cracks on interior walls caulked sealed or aasketed. <br />Recessed Linhts Sealed from conditioned & insulated from ventilated attic spaces. <br />Ductwork All ductwork located in conditioned space. <br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust <br /> by-products to outside. Combustion cooking appliances see section 606.1.A.3 <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-11. Switch or clearly marked circuit breaker (electric) <br /> or cutoff (aas) must be orovided. External or built-in heat trap reauired. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have <br /> a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. <br />Shower Heads 612.1 Water flow must be restricted to no more than 3 aallons per minute at 80 PSIG. <br />Air Distribution System 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br /> sealed, insulated, and installed in accordance with the criteria of Section 61 O. Ducts in unconditioned <br /> attics must be insulated to a minimum of R-6. Air handlers shall not be installed in attics unless in <br /> mechanical closet. <br />HV AC Controls 607.1 Separate readilv accessible manual or automatic thermostat for each system. <br />Insulation 604.1, 602.1 Ceilinas-Min. R-19. Common walls-Frame R-11 orCBS R-3 both sides. Common ceilino & floors R-11. <br /> <br />-6. <br />
The URL can be used to link to this page
Your browser does not support the video tag.