Laserfiche WebLink
<br />Department of Community Affairs - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />FORM 600A-93 Residential Whole Building Performance Method A CENTRAL 4 5 6 <br /> <br /> <br />PROJECT NAME: <br />AND ADDRESS: <br /> <br />OWNER: <br /> <br />1. New construction or addition <br />2, Single family detached or Multifamily attached <br />3. If Multifamily-No. of units covered by this submission <br />4. If Multifamily, is this a worst case (yes I no) <br />5, Conditioned floor area (sq, ft,) <br />6. Predominant eave overhang (ft,) <br />7, Porch overhang length (ft.) <br />8. Glass type and area: <br />a, Clear glass <br />b, Tint, film or solar screen <br />9, Floor type and insulation: <br />a, Slab on grade (R-value + perimeter) <br />b. Wood, raised (R-value + sq, ft,) <br />c, Concrete, raised (R-value) <br />10, Net Wall type, area and insulation: <br />a, Exterior: 1, Concrete block (Insulation R-value) <br />2, Wood frame (Insulation R-value) <br />3, Steel frame (Insulation R-value) <br />4, Log (Insulation R-value) <br /> <br />b, Adjacent: 1, Concrete block (Insulation R-value) <br />2, Wood frame (Insulation R-value) <br />3, Steel frame (Insulation R-value) <br />4, Log (Insulation R-value) <br />11, Ceiling type, area and insulation: <br />a, Under attic (Insulation R-value) <br />b, Single assembly (Insulation R-value) <br />12. Air distribution system: <br />a, Ducts (Insulation + Location) <br />b, Air Handler( Insulation + Location) <br />13. Cooling system: <br />(Types: central-split, central-single pkg., room unit, PTAC" none) <br /> <br />14, Heating system: <br />(Types: heat pump, elec. strip, nat. gas, L.P. gas, room or PTAC, none) <br />15. Hot water system: <br />(Types: elec., natural gas, solar, L.P. gas, none) <br />16, Hot Water Credits: <br />a, Heat Recovery (HR) <br />b, Dedicated Heat Pump(DHP) <br />17, Infiltration practice: 1, 2 or 3 <br />18. HV AC Credits (Type in Letter designation: CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, RS-Attic radiant barrier, MZ-Multizone) <br />19. EPI (must not exceed 100 points) <br /> <br />a, Total As-Built points <br />b, Total Base points <br /> <br /> <br />EPI = Total As-Buiij points X 100 <br />Total Base points <br /> <br />calculation are in compliance with the <br /> <br />Review of plans and specifications covered by this calculation indicates compliance with <br />the Florida Energy Code. Before construction' pleted, this building will be inspected <br />for compliance in acco nee h Seelio . F.S. <br /> <br />OWNER AGENT: <br /> <br />DATE: '3 -1 (-7/ <br />. a Energy Code. S '7 . <br />DATE: -2- 7 <br /> <br />-1- <br /> <br /> <br />12a, <br />12b, <br />13a. <br />13b, <br />13c, <br />14a, <br />14b, <br />14c, <br />15a, <br />15b, <br />16a, <br />16b, <br />17. <br />18, <br /> <br />'19, <br /> <br />19a, <br />19b. <br /> <br />DATE: <br /> <br />CK <br /> <br />1, <br />2. <br />3. <br />4. <br />5. <br />6, <br />7, <br /> <br />- <br />, <br /> <br />l-- <br /> <br />T~-~<.;) <br />, <br />1< if (( <br />'7r <br />Single Pane <br />sq, ft. <br />t-{ ~ S' ..r sq, ft. <br /> <br />sq, ft, <br />ft, <br />ft, <br />Double Pane <br />sq, ft, <br />sq, ft, <br /> <br />8a, <br />8b. <br /> <br /> ,- <br />9a. R= D ll{~~r I. ft, <br />9b. R= sq, ft, <br />9c, R= sq, ft. <br />10a-1 R= 7' i~'7 sq, ft, <br />10a-2 R= sq, ft. <br />10a-3 R= sq. ft, <br />10a-4 R= sq. ft, <br />1 Ob-1 R= n If? sq, ft, <br />10b-2 R= sq, ft, <br />10b-3 R= sq. ft. <br />1 Ob-4 R= sq, ft, <br />11a. R= 3D '"J.. ~c sq, ft, <br />llb, R= sq, ft, <br /> <br />R= Ii::> , UiV(,oy' (cond./uncond.) <br />R= q.J..f, UN~' (cond./uncond.) <br />Type: (1..eAj/f1!. ( <br />SEERlEERlCOP:~O <br />Capacity: { 1-6 () l( <br />Type: H~;l L~ <br />HSPF/COP/AFUE: '7-'- <br />Capacity: 1./ 7000 <br />Type: .$:( e t <br />EF: t q I <br /> <br />?- <br /> <br />,73 <br />J/ I.{ '}-o--r <br />~ 0 s-u ( <br />