Laserfiche WebLink
<br /> <br />Department of Community Affairs - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />FORM 600A-93 Residential Component Prescriptive Method A CENTRAL 4 5 6 <br /> <br /> <br />PROJECT NAME: <br />AND ADDRESS: <br /> <br />OWNER: tJ,I1!-( l?tl.iJ~~OPFt<nl3 --::j::',v." . <br /> <br />1. New construction or addition <br />2. Single family detached or Multifamily attached <br />3. If Multifamily-No. of units covered by this submission <br />4. If Multifamily, is this a worst case (yes I no) <br />5. Conditioned floor area (sq. ft.) <br />6. Predominant eave overhang (ft.) <br />7. Porch overhang length (ft.) <br />8. Glass area and type: <br />a. Clear glass <br />b. Tint, film or solar screen <br />9. Floor type and insulation: <br />a. Slab on grade (R-value + perimeter) <br />b. Wood, raised (R-value + sq. ft.) <br />c. Concrete, raised (R-value) <br />10. Net Wall type area and insulation: <br />a. Exterior: 1. Concrete (Insulation R-value) <br />2. Wood frame (Insulation R-value) <br />3. Steel (Insulation R-value) <br />4. Log (Insulation R-value) <br /> <br />b. Adjacent: 1. Concrete (Insulation R-value) <br />2. Wood frame (Insulation R-value) <br />3. Steel (Insulation R-value) <br />4. Log (Insulation R-value) <br />11. Ceiling type area and insulation: <br />a. Under attic (Insulation R-value) <br />b. Single assembly (Insulation R-value) <br />12. Air distribution systems <br />a. Ducts (Insulation + Location) <br />b. Air Handler( Insulation + Location) <br />13. Cooling system <br />(Types: central-split, central-single pkg'., room, unit, PTAC., none) <br /> <br />14. Heating system: <br />. (Types: heat pump, elec. strip, nat. gas, L.P. gas, room or PTAC, none) <br />15. Hot water system: <br />(Types: elec., natural gas, solar, L.P. gas, none) <br />16. Hot Water Credits: <br />a. Heat Recovery (HR) <br />b. Dedicated Heat Pump{DHP) <br />17. Infiltration practice: 1, 2 or 3 <br />18. HV AC Cr4!dits (Type in Letter designation: CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, RS-Attic radiant barrier. MZ-Multizone) <br />19. EPI (must not exceed 100 points) <br /> <br />a. Total As-Built points <br />b. Total Base points <br /> <br />Please Print <br /> <br />1. NeW <br />2. mu.l-hfO.m,l,/ <br />3. d.. <br />4. 'I f.s <br />5. 073 <br />6. d. <br />7. <br /> Single Pane Double Pane <br />8a. 77,1 sq. ft. sq. ft. <br />8b. sq. ft. sq. ft. <br />9a. R= <5 , I~~ ,S" I. ft. <br />9b. R= , sq. ft. <br />9c. R= , sq. ft. <br />1 Oa-1 R= 5 vo9 sq. ft. <br />10a-2 R= sq. ft. <br />10a-3 R= sq. ft. <br />1 Oa-4 R= sq. ft. <br />10b-1 R= sq. ft. <br />10b-2 R= II -3:.J..O sq. ft. <br />10b-3 R= sq. ft. <br />10b-4 R= sq. ft. <br />11a. R= .:30 <=t70 sq. ft. <br />11b. R= sq. ft. <br />12a. R= /.p , U.n{Oro(COnd.luncond.) <br />12b. R= L-J.JS" , lond (cond.luncond.) <br />13. Type: Ccntv 0... \ <br /> SEERlEERlCOP: ID .CO <br />14. Type: +\ t'O.:L Pl..l rn ? <br /> HSPF/COP/AFUE: -1.0 <br />15. Type: CI€G <br /> EF: \C( \ <br />16a. <br />16a. <br />17. ~ <br />18. <br />'19. CfO.4 I <br />19a. 1l.C ~ I a-... <br />19b. ~O~,l <br /> <br /> <br />OWNER AGENT: <br /> <br />------_._---,-~- ---..---- _._------~--_._-------.,--_.- ------'---.--- <br /> <br />DATE: <br /> <br />-1- <br /> <br />Review of plans and specifications covered by this calculation Indicates compliance with <br />the Florida Energy Code. re constructl . completed, this building will be Inspected <br />for compliance in acco with Section .908, F.S. <br /> <br />~ <br /> <br />DATE: <br />