Laserfiche WebLink
<br />tre <br /> <br />TOW)ON-ROGER) <br />ENGINEERING INC. <br /> <br />ENGINEERING. PLANNING, ENVIRONMENTAL PERMl1TING <br /> <br />December I, 1997 <br /> <br />Mr. Bill Burgess <br />City of Zephyrhills <br />5335 8th Street <br />Zephyrhills, Florida 33540 <br /> <br />RE: Zephyrhills Medical Center <br />Retaining Wall <br />TRE Project No. 96305 <br /> <br />Dear Mr. Burgess: <br /> <br />Some time ago, we submitted a retaining wall detail for the above-referenced project <br />which showed No.7 reinforcement bars placed on 24-inch centers. As you may be <br />aware, No.6 re-bars were delivered to the site. Wishing to use them instead of <br />returning them, the contractor proposed placing them at 16-inch centers to make up the <br />difference. We verified with our structural engineer that this is an acceptable and <br />equivalent reinforcement configuration. <br /> <br />Please advise me if you have any additional questions regarding this issue We <br />appreciate your attention and cooperation in this matter. <br /> <br />Sincerely, <br /> <br /> <br />Edw J. ogers, P.E. <br />Towson-Rogers Engineering, Inc. <br /> <br />c: \edpro;ect \ 96305 \bbn201.doc <br /> <br />5514 7TH STREET · ZEPHYRHILLS, FLORIDA 33540 813-788-0400 <br />