My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
97-6861
Zephyrhills
>
Building Department
>
Permits
>
1997
>
97-6861
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 3:05:20 PM
Creation date
8/4/2006 8:21:52 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
97-6861
Building Department - Name
BROWN,RUSSELL
Address
4745 SILVER CR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />ADDITIONAL TABLES <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A.18 HEATING CREDIT MULTIPLIERS HCM <br />~YST~M JYP~,____ ~______ ___ -.-~~__~_,_._IiEATINg l:F:~pIT M~~TIP~I~~~ (HCM) <br />Allie Radiant Barrier HCM '____~_____., ,.. ____, <br />Muliizone HCM ---.-____.,.JJ~____ _,____ <br />~~t~ral Gas Af~_ ,68-,72 .73-.7L....____Z~_JJg___ .___~~-JlL, <br />HCM ,61 ,56 --._:~L__.u ___,~Q_.__ <br />~M n ,n m m <br /> <br />LPG <br /> <br />:13.8-,~g__ <br />.47 <br />.60 <br /> <br />.93 & Up <br />.44 <br />.57 <br /> <br />6A-19 COOLING CREDIT MULTIPLIERS CCMI <br />____~y~IEM TYfE -- COOLING CREDIT MUL TIPLlERS ~C~ ~_.~-----_._----~-~-----~--_.._- ---"----.------- <br />g~tin.!l fans - 411~') - ,.' <br />Cross Ventilation .9 * __ 'Credit may be taken for only <br />Whole House Fan .95' one of these system types concurrently, <br />Multizone ---- -~~-~._-,--- ,95 <br />Allie Radiant Barrier .95 <br /> <br />-- _SYSTEM TYPE -------- ---- - -----. HOTWATERCREOlTrTlflUERS(HWCM1_ __ <br />Heat Recovery Unit ~- WlIIL. -. - '-- ~- AirComl"",,, _ _ __ _ __ _ . !lea"""" <br />---- -----_---.HWCM -- ,L____ __~_,__ ___ -___u, 8 <br />~edlca~~~~e~~~m~_ __ ~j~lL_==.--- -~-~49--=t==-2~~_=~~~~ --=---=:~~~=-._ -1--J'5,~ ~p <br />Solar -EE__. - -- ~=- .1.0:1,9 :=:-1 2.0-2,9 -=-r- --.3,~.9 f _.4,0-4,9 ___ __ _ 5,0 &. Up <br />--1:1WC~_ ---=C_.BL-.=r== 42 --=r=__ ---21_ _ _ _.17 <br />- - A HWM MUST BE USED IN CONJUNCTION WITH ALL HWCM. SEE TABLE 6A.9 EF MEANS ENERGY FACTOR. <br /> <br />6A-21 INFIL TRA TlON REDUCTION PRACTICE COMPLIANCE CHECKLIST (SEE SECTION 606) <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE #1 606.1 COMPLY WITH All INFilTRATION PRESCRIPTIVES. <br />Windows Maximum of 0.34 CFM per linear foot of operable sash crack (includes sliding glass doors\. <br />Exterior & Adiacent Doors Maximum of 0.5 CFM per SQ. ft. of door area' solid core wood panel insulated or glass doors only. <br />Exterior Joints & Cracks To be caulked aasketed weatherstriooed or otherwise sealed. <br />PRACTICE #2 606.1 COMPLY WITH #1 AND THE FOllOWING: <br />Exterior Walls and Floors Too olate oenetrations sealed. Infiltration barrier installed. Sole olate/floor ioint caulked or sealed. <br />Exterior Walls & CeilinQs Penetrations. joints and cracks on interior surface caulked sealed or aasketed. <br />Ductwork Ductwork in unconditioned space must be sealed. <br />Fireplaces EQuiooed with outside combustion air, doors, and flue dampers. 1---- <br />Exhaust Fans Equipped with dampers. Combustion devices see 606.1 A2 <br />PRACTICE #3 606,1 COMPLY WITH PRACTICES #1 AND #2 AND THE FOllOWING: <br />Ceilinas Infiltration barrier installed. <br />Interior Walls Too oenetrations sealed or ioints & cracks on interior walls caulked sealed or qasketed. <br />Recessed liahts Sealed from conditioned & insulated from ventilated attic soaces. --- -- <br />Ductwork All ductwork located in conditioned space. <br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust <br /> by-products to outside. Combustion cooking appliances see section 606.1 A3 <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.) <br />COMPONENTS SECTION REQUIREMENTS , CHECK <br />Water Heaters 612,1 Comply with efficiency requirements in Table 6-11. Switch or clearly marked circuit breaker (electric) <br /> or cutoff (gas) must be orovided. External or built-in heat trap required. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have <br /> a pump timer. Gas soa & 0001 heaters must have a minimum thermal efficiencv of 78%. <br />Shower Heads 612,1 Water flow must be restricted to no more than 3 gallons per minute at 80 PSIG. <br />Air Distribution System 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br /> sealed. insulated, and installed in accordance with the criteria of Section 61 O. Ducts in unconditioned <br /> attics must be insulated to a minimum of R-6. Air handlers shall not be installed in attics unless in <br /> mechanical closet. <br />HVAC Controls 607.1 Separate readilv accessible manual or automatic thermostat for each svstem, <br />Insulation 604.1,602.1 Ceilinqs-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. Common ceilina & floors R-ll. <br /> <br />.~. <br />
The URL can be used to link to this page
Your browser does not support the video tag.