<br />ADDITIONAL TABLES <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A-1S HEATING CREDIT MULTIPLIERS (HCM) <br />. ___~Y~TE... TyPL______.-,---.__ H~~Tlli~ ~R~QILM~~TIP.LJ~R~ tHc:M) --------. "--.------- <br />Attic Radiant Barrier HCM .98 ._____,___. __n_____ .'. <br />Multizone HCM .95 _.._--~-- <br />Natural Gas ~!!L..... .68-.72 ,73-.77 .~ .__.....18- .82~. _.,83-,8L.__ ~.~~:,!lg__ . ,!jHUp <br />HCM .61 ,56 .53 ,50 .47 ,44 <br /> c-' --------- -,- --".--- <br />LP Gas HCM .77 .72 ,67 .63 .60 .57 <br /> <br />6A-19 COOLING CREDIT MULTIPLIERS CCM) <br /> SYSTEM TYPE COOLING CREDIT~L1E!tS tCCM) -----~---~~_.._- -- -----_...._^._._~---- <br />_Ceiling Fans (86' <br />Cross Ventilation ']5' 'Credit may be taken for only <br />_~hQ!~. House F?n . .95' one of these system types concurrently. <br />Multizone .95 <br />Attic Radiant Barrier ,95 <br /> <br />~_SY.sTEM1YP.E_ --- - . --~- _._~_ ..~__~HQT WATER CREDJULI/PJ.lEAS (HWCM) <br />Heat Recovery Unit _With - -- - .- n_ - - ~ ...__._..AirCQIJdlliQner ______....__ ._____u__ _ _ Heat Pump <br /> <br />- .- .....--._-~ __HWCM -.. -.... .-- _ _ ....______ _. __~.__n .., _... _. _.. _ .8 <br /> <br />Dedicated Heat Pump b EF__ ----- ~ - Z<>2A<l ---f- - - ZO'2." - _3D!'" .. -1 <br />llWCM ~=[ .44 ==t=:__ ."35 _U U_ ---J- - ",9______ <br />. ;Ol~~ -. -- .-- ..=- EF - -_::..-==~~~~ - 1.0- 1.9 .~I 2,0-2.9._ -.-J . .3.0-3.9 _ .. _ -. 4,0-4.9 <br />-. - n .. ._HWCM~_~=r=_~84. _ 42 .. __ _. ___ 28 _ _ . _ __ ..21 . <br />A HWM MUST BE USED IN CONJUNCTION WITH ALL HWCM. SEE TABLE 6A.9, EF MEANS ENERGY FACTOR. <br /> <br />3,5 & Up <br />,25 <br />5,0 & Up <br />.17 <br /> <br />6A-21 INALTRATlON REDUCTION PRACTICE COMPLIANCE CHECKLIST (SEE SECTION 6061 <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE tt 606.1 COMPLY WITH All INFilTRATION PRESCRIPTIVES. <br />Windows Maximum of 0.34 CFM oer linear foot of ooerable sash crack (includes slidina alass doors). <br />Exterior & Adiacent Doors Maximum of 0,5 CFM oer sa. ft. of door area: solid core wood oanel insulated or Qlass doors onlv. <br />Exterior Joints & Cracks To be caulked aasketed weatherstripped or otherwise sealed. <br />PRACTICE #2 ) 606.1 COMPLY WITH #1 AND THE FOllOWING: <br />'-Exterior WaHs-and Floors Top olate oenetrations sealed. Infiltration barrier installed. Sole olate/floor ioint caulked or sealed. <br />Exterior Walls & Ceilinos Penetrations ioints and cracks on interior surface caulked sealed or aasketed. <br />Ductwork Ductwork in unconditioned soace must be sealed. <br />Fireolaces Eauiooed with outside combustion air. doors and flue dampers. <br />Exhaust Fans Eauipped with dampers. Combustion devices see 606.1 A2 <br />PRACTICE #3 606.1 COMPLY WITH PRACTICES #1 AND #2 AND THE FOllOWING: <br />Ceilinos Infiltration barrier installed, <br />Interior Walls Too oenetrations sealed or ioints & cracks on interior walls caulked sealed or aasketed. <br />Recessed Liohts Sealed from conditioned & insulated from ventilated attic spaces. <br />Ductwork All ductwork located in conditioned soace. <br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust <br /> by-products to outside, Combustion cooking appliances see section 606.1 A3 <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences,) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-11. Switch or clearly marked circuit breaker (electric) <br /> or cutoff (aasl must be orovided. External or built-in heat trap reauired. <br />Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have <br /> a pumo timer. Gas soa & 0001 heaters must have a minimum thermal efficiency of 78%. <br />Shower Heads 612.1 Water flow must be restricted to no more than 3 aallons per minute at 80 PSIG. <br />Air Distribution System 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br /> sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned <br /> attics must be insulated to a minimum of R-6. Air handlers shall not be installed in attics unless in <br /> mechanical closet. <br />HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. <br />Insulation 604,1,602.1 Ceilinas-Min, R-19. Common walls-Frame R-ll or CBS R-3 both sides, Common ceilina & floors R-11. <br /> <br />,~. <br />