Laserfiche WebLink
<br />Department of Community Affairs <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />Residential Whole Building Performance Method A <br />SUMMERSET :BUILDER: BAY VILLAGE BUILDERS <br />6943 STEPHENS PATH :PERMITTING :CLIMATE- <br />ZEPHYF.~HILLS, FLOF.~ID?1: OFFICE: [Try OF ZEPH: ZONE: 4 :~5: _: 6:_l <br />MODEL : PEF.~MIT NO.&' ~?S-6 : JUF.~ISDIC:TION NO.611600 <br />CK <br /> <br />FORI"I 600A-'33 <br />PF.:OJECT NAME: <br />AND ADDPESS: <br /> <br />OWNEP: <br /> <br />1. New construction or addition <br />2. Single family detached or Multifamily attached <br />3. If Multifamily-No. of units <br />4. If Multifamily, is this a l.<Jorst case (yes/nc':> <br />5. Conditioned floor area (sq. ft.) <br />6. Predominant eave overhang (ft.) <br />7. Porch overhang length (ft.) <br />8. Glass area and type: <br />a. Clear Glass <br />b. Tint, film or solar screen <br />9. Floor type and insulation: <br />a. Slab on grade (P-value, perimeter) <br />10.Net Wall type area and insulation: <br />a. Exterior: 1. Concrete (Insulation P-value) <br />a. Exterior: 2. Wood frame (Insulation R-value) <br />b. Adjacent: 2. Wood frame (Insulation P-value) <br />11.Ceiling type area and insulation: <br />a. Under attic (Insulation R-value) <br />12.Air distribution systems <br />a. Ducts (Insulation + Location) <br />13.Cooling system <br /> <br />l4.Heating System: <br /> <br />l5.Hot water system: <br /> <br />,6.Hot Water Credits: (HR-Heat Recovery, <br />DHP-Dedicated Heat Pump) <br />,7.Infiltration practice: 1, 2 or 3 <br />,8.HVAC Credits (CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, PB-Attic radiant <br />barrier, MZ-Multizone) <br />9.EPI (must not exceed 100 points) <br />a. Total As-Built points <br />b. Total Base points <br /> <br />SN: 2345 <br /> <br />C:ENTF.:AL <br /> <br />1. New Construction <br />~. tlingle-Family <br />o <br /> <br />--, <br />..:J. <br /> <br />4. <br />5. 1600.00 <br />6. 1.00 <br />7 . O. 00 <br />Single Pane <br />8a.337.4sqft <br />8b. O.Osqft <br /> <br />Double Pane <br />O.OOsqft <br />O.OOsqft <br /> <br />'3a . F.~::: O. 00 , 1 75. 00 f t <br /> <br />10a-l P= 4.30, <br />10a-2 F.~=11.00, <br />10b'--2 F.:=11.00, <br /> <br />713.40sqft_ <br />175.70sqft_ <br />124.60sqft_ <br /> <br />11 a. F.~=30. 00 , <br /> <br />1600.00sqft_ <br /> <br />12a. P= 6.00, uncond <br />13. Type: Central AIC <br />SEEP: 12.00 <br />14. Type: Heat Pump <br />HSPF: 7.20 <br />15. Type: EIE?ctric <br />EF-: 0.90 <br /> <br />16. <br /> <br />17. <br />18. <br /> <br />1 <br /> <br />1'3. <br />1 ':1a. <br />l'3b. <br /> <br />'34. 06 <br />2'3702.63 <br />31578.10 <br /> <br />------------------------------------------------------------------------------ <br /> <br />--------------------------.------------.-.---------.--.--------------.----------------- <br /> <br />Peview of the plans and specifications <br />covered by this calculation indicates <br />compliance with the Florida Energy <br />Code. Before construction is completed <br />this building will be inspected for <br />compliance in accordance with Section <br />553.908 F.S. <br /> <br />Hereby certify that the plans and <br />pecifications covered by this calcu- <br />ation are in compliance with the <br />lorida Energy Code. <br /> <br />:;:~EPARED BY: ~ ~ _ ~. <br />CiTE: ~'" \2..-~\ C( '1 <br />, <br /> <br />~\~ <br /> <br />hereby certify that this building is <br />1 compliance with the Florida Energy <br />)de. <br /> <br />JNER~~.q_ <br />HE: "-01~"'11 <br /> <br />BUILDING <br />DATE: <br /> <br />71j':f.J!i;r=-b~ <br />