Laserfiche WebLink
<br />Department of Community Affairs <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />FORM 600A-93 Residential Whole Building Performance Method A <br />PROJECT NAME: Scudder Residence BUILDER: G.L. Steve Construction <br />AND ADDRESS: --III , PERMITTING 4 CLIMATE <br />b 7'1'11l~ OFFICE:eITI{ ~-J:~III'I/!It'/. ZONE: 41~ 51_1 61_1 <br />OWNER: PERMIT NO'6f16!3 JURISDICTION NO."II~~) <br /> <br />1. New construction or addition 1. New Construction <br />2. Single family detached or Multifamily attached 2. Single-Family <br />3. If Multifamily-No. of units 3. 0 <br />4. If Multifamily, is this a worst case (yes/no) 4. <br />5. Conditioned floor area (sq.ft.) 5. 2140.00 <br />6. Predominant eave overhang (ft.) 6. 0.75 <br />7. Porch overhang length (ft.) 7. 25.30 <br />8. Glass area and type: Single Pane <br />a. Clear Glass 8a. O.Osqft <br />b. Tint, film or solar screen 8b.275.9sqft <br />9. Floor type and insulation: <br />a. Slab on grade (R-value, perimeter) <br />10.Net Wall type area and insulation: <br />a. Exterior: 1. Concrete (Insulation R-value) 10a-1 R= 5.00, 1290.87sqft____ <br />b. Adjacent: 2. Wood frame (Insulation R-value) 10b-2 R=11.00, 132.40sqft____ <br />11.Ceiling type area and insulation: <br />a. Under attic (Insulation R-value) <br />12.Air distribution systems <br />a. Ducts (Insulation + Location) <br />13.Cooling system <br /> <br />SN: 8132 <br /> <br />CENTRAL <br /> <br />Double Pane <br />O.OOsqft <br />O.OOsqft <br /> <br />9a.R= 0.00 , 214.60 ft <br /> <br />11a.R=22.00 , 2568.~osqft____ <br /> <br />14.Heating System: <br /> <br />12a. R= 6.00, uncond <br />13. Type: Central A/C <br />SEER: 9.70 <br />14. Type: Heat Pump <br />HSPF: 6.60 <br />15. Type: Electric <br />EF: 0.88 <br /> <br />15.Hot water system: <br /> <br />16.Hot Water Credits: (HR-Heat Recovery, <br />DHP-Dedicated Heat Pump) <br />17.Infiltration practice: 1, 2 or 3 <br />18.HVAC Credits (CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, RB-Attic radiant <br />barrier, MZ-Multizone) <br />19.EPI (must not exceed 100 points) <br />a. Total As-Built points <br />b. Total Base points <br /> <br />16. <br /> <br />17. <br />18. <br /> <br />2 <br />CF CV <br /> <br />19. <br />19a. <br />19b. <br /> <br />83.34 <br />32428.57 <br />38910.96 <br /> <br />------------------------------------------------------------------------------- <br /> <br />------------------------------------------------------------------------------- <br /> <br />I Hereby certify that the plans and <br />specifications covered by this calcu- <br />lation are in compliance with the <br />Florida Energy Code. <br /> <br />PREPARED BY: <br />DATE: <br /> <br />Review of the plans and specifications <br />covered by this calculation indicates <br />compliance with the Florida Energy <br />Code. Before construction is completed <br />this building will be inspected for <br />compliance in accordance with Section <br />553.908 F.S. <br /> <br />I hereby certify that this building is <br />in compliance with the Florida Energy <br />Code. ~ <br />I J ' .' <br />OWNER/AGllNT: (l - 1- " r: {(7({.'>'y <br />DATE: a-t.1~1 tA...-J < , ~"I{ ( I <1 q '1 <br /> <br />, . <br /> <br />BUILDING oit~: ~~ <br />DATE: <1, '17 <br />