My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
97-7325
Zephyrhills
>
Building Department
>
Permits
>
1997
>
97-7325
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 3:04:22 PM
Creation date
8/15/2006 8:30:20 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
97-7325
Building Department - Name
BILL POE CONST
Address
6310 SILVER OAKS
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />ADDITIONAL TABLES <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A-18 HEATING CREDIT MULTIPLIERS (HCM) <br /> SYSTEM TYPE HEATING CREDIT MULTIPLIERS (HCMl <br />Attic Radiant Barrier HCM _98 <br />Multizone HCM .90 <br /> AFUE .68-.72 .73-n .78-.82 .83-_87 .88-.92 .93 & Uo <br />Natural Gas HCM .61 .56 .53 .50 .47 .44 <br />LP Gas HCM .77 _72 _67 .63 .60 .57 <br /> <br />6A-19 COOLING CREDIT MULTIPLIERS CCM) <br /> SYSTEM TYPE COOLING CREDIT MULTIPLIERS (CCM) <br />Ceilina Fans .86' <br />Cross Ventilation .90' 'Credit may be taken for only <br />Whole House Fan _90' one of these system types concurrently. <br />Multizone .95 <br />Attic Radiant Barrier .95 <br /> <br />6A-20 HOT WATER CREDIT MULTIPLIERS (HWCMl <br />SYSTEM TYPE HOT WATER CREDIT MULTIPLIERS (HWCMT <br />Heat Recovery Unit With Air Conditioner Heat Pump <br />HWCM .62 .58 <br />Dedicated Heat Pump EF 2.0-2.49 I 2.5-2_99 3.0-3.49 I 3.5 & Up <br />HWCM .44 I .35 _29 I .25 <br /> A HWM MUST BE USED IN CONJUNCTION WITH ALL HWCM. SEE TABLE 6A-9. EF MEANS ENERGY FACTOR. <br /> <br />6A-21 INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE #1 606_1 COMPLY WITH All INFilTRATION PRESCRIPTIVES. <br />Windows 606.1 Maximum of 0.34 CFM per linear foot of operable sash crack (includes slidina alass doors). <br />Exterior & Adiacent Doors 606.1 Maximum of 0.5 CFM per sa_ ft. of door area; solid core, wood panel, insulated or alass doors onlv. <br />Exterior Joints & Cracks 606.1 To be caulked, aasketed, weatherstripped or otherwise sealed. <br />PRACTICE #2 6062 COMPLY WITH #1 AND THE FOllOWING: <br />Exterior Walls and Floors Top plate penetrations sealed_ Infiltration barrier installed. Sole plate/floor ioint caulked or sealed. <br />Exterior Walls & CeilinQs Penetrations, ioints and cracks on interior surface caulked, sealed or aasketed_ <br />Ductwork Ductwork in unconditioned space must be sealed. <br />Fireolaces Eauipped with outside combustion air, doors, and flue dampers. <br />Exhaust Fans Eauipped with dampers_ Combustion devices see 606.1.A.2 <br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust to outside. <br /> Cookina appliances shall be dampered and use intermittent ianition_ <br />PRACTICE #3 606.2 COMPLY WITH PRACTICES #1 AND #2 AND THE FOllOWING: <br />CeilinQs Infiltration barrier installed. <br />Interior Walls Top penetrations sealed or ioints & cracks on interior walls caulked, sealed or aasketed. <br />Recessed Liahts Sealed from conditioned & insulated from ventilated attic spaces. <br />Ductwork All ductwork located in conditioned space. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.l <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker (electric) <br /> or cutoff (aas) must be provided. External or built-in heat tran renuired. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have <br /> a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%_ <br />Shower Heads 612_1 Water flow must be restricted to no more than 3 aallons per minute at 80 PSIG. <br />HV AC Duct Construction 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br />Insulation & Installation sealed, insulated, and installed in accordance with the criteria of Section 904.6. Duct in unconditioned <br /> space and air handlers located in attics must be insulated to a minimum of R-6. Air handlers shall not <br /> be installed in attics unless in mechanical closet <br />HV AC Controls 607_1 Separate readilv accessible manual or automatic thermostat for each svstem. <br />Insulation 604.1 , 602.1 Ceilinas-Min_ R-19_ Common walls-Frame R-11 or CBS R-3 both sides. Common ceilina & floors R-11. <br /> <br />-6- <br />
The URL can be used to link to this page
Your browser does not support the video tag.