<br />. WINTER POINT MULTIPLIERS (WPM) <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A-10 WINTER OVERHANG FACTORS (WOF) <br />J OH RATIO I .00-.11 I .12-.17 .18-.26 .27-.35 I .36-.46 I .47--57 .58-.70 .71-.83 .84-1.18 11.19-1.72 1.73-2.73 2.74+ <br /> SINGLE PANE GLASS <br />N toO 1.03 1.05 1.08 UO 1.13 1.15 1.18 1.20 1.24 1.29 1.34 <br />NE/NW 1.00 1.07 1.10 1.15 1.20 1.25 1.30 1.35 1.39 1.50 1.59 1.67 <br />E/W 1.00 _71 .57 .19 -.20 -.65 -1.05 -lA8 -2_03 -3.01 -4.06 -5.04 <br />SE/SW 1.00 .93 .90 .80 .68 .54 .39 .22 .05 -.33 -.71 -1.01 <br />ba: S 1.00 .95 _92 _83 _70 -54 .36 _13 -_13 -.70 -_98 -to9 <br />~[ DOUBLE PANE GLASS <br />N toO 1.05 1.07 Ul U4 U8 1.21 1.24 1.28 1.34 1-40 lA7 <br />NE/NW 1.00 1.11 U6 1.24 1.32 1.41 1.48 1.56 1.63 LBO 1.94 2.08 <br />E/W 1.00 .88 _82 .66 .50 .31 .15 -.03 -_26 -.66 -1.10 -1.50 <br />SE/SW 1.00 .95 .92 _85 _76 _65 .54 Al .28 -.01 -.30 -_52 <br />S 1.00 _96 _94 .87 .78 .65 .51 .33 .13 -_30 --51 -.60 <br />OH LENGTH' Oft. 1 ft. l%ft_ 2ft. 3ft. 3% ft. 4% ft. 5% ft. 6% ft. 9'1,ft. 14ft_ 20ft.+ <br /> "TO SELECT BY OVERHANG LENGTH, NO PART OF GLASS SHALL BE MORE THAN 8 FT. BELOW THE OVERHANG. <br /> <br />6A-11 WALL WINTER POINT MULTIPLIERS <br />FRAME <br /> <br />R-VALUE <br />0-6.9 <br />7-10.9 <br />11-12.9 <br />13-18-9 <br />19-25_9 <br />26& U <br /> <br />WOOD <br />EXT ADJ <br />6.8 5.3 <br />2.5 2.1 <br />2_0 1.8 <br />LB 1.6 <br />1.1 to <br />.7 _7 <br /> <br />STEEL <br />EXT ADJ <br />9A 6.7 <br />4A 3.3 <br />3_3 2.6 <br />3.0 2A <br />2_6 2.2 <br />lA 1.2 <br /> <br /> <br />CONCRETE BLOCK1 <br />INT. INSULATION <br />NORMAL WT. <br />EXT ADJ <br />6.0 3.1 <br />3.8 2_3 <br />2_9 1.9 <br />2.3 1.5 <br />1.5 1.1 <br />_8 .7 <br />-5 .5 <br /> <br /> <br />6A-12 DOOR WINTER POINT MULTIPLIERS 6A-13 CEILING WINTER POINT MULTIPLIERS (WPM) <br />DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOFING <br /> R-VALUE WPM R-VALUE WPM CEILING TYPE <br />WOOD 7.6 5.9 19-219 1.0 10-10.9 1.8 R.VALUE DROPPED EXPOSED <br /> 22-25_9 .9 11-12.9 1-6 10-13.9 1.2 1.3 <br />INSULATED 5_1 4_0 26-29.9 .7 13-18-9 1.5 14-20.9 .7 .7 <br /> 30-37.9 .6 19-25.9 U 21 & UP A .3 <br /> 38 & UP A 26-29.9 .6 <br /> ::lO!l. Un 4 <br />6A-14 FLOOR WINTER POINT MULTIPLIERS (WPMI <br />SLAB-oN.GRADE RAISED RAISED WOOD' <br />EDGE INSULATION CONCRETE POST OR PIER STEM WALL wi UNDER ADJACENT <br /> CONSTRUCTION FLOOR INSULATION <br />R.V ALUE WPM R-VALUE WPM R-V ALUE WPM WPM WPM <br />0-2_9 2.5 0-2_9 4_0 0-6.9 7.9 N/A 5.3 <br />3-4_9 -1-7 3-4.9 LB 7-10.9 2_1 .7 2.1 <br />5-6_9 -2A 5-6.9 1.1 11-18.9 1-5 -5 1.8 <br />7 R.lln .? 7 7 !I. Iln A HI !I. Iln Q .3 1.0 <br /> <br />WPM) <br /> <br />6A.15 INFILTRATION WINTER POINT MULTIPLIERS (WPM) <br />INFILTRATION PRACTICE WPM <br />SEE TABLE 9P <br />PRACTICE #1 6.2 <br />PRACTICE #2 4_1 <br /> <br />6A-16 DUCT MULTIPLIERS OM <br /> <br />SUPPLY DUCTS IN <br />UNCONDITIONED SPACE <br /> <br /> <br />RETURN DUCTS <br />IN UNCONDITIONED SPACE <br />1.14 <br />1.10 <br />1.09 <br />UO <br />1.07 <br /> <br />RETURN DUCTS <br />IN CONDITIONED SPACE <br />1.10 <br />to7 <br />to6 <br />toO <br />toO <br /> <br />SUPPLY DUCTS IN <br />ONDITIONED SPACE' <br /> <br />6A-17 HEATING SYSTEM MULTIPLIERS lHSMI <br />SYSTEM TYPE HEATING SYSTEM MULTIPLIERS (HSM) <br />Central Heat HSPF 6AO-6.79 6_80-6.89 6_90-7.39 7AO-7.89 7.90-8-39 8.40.8_89 8-9-9_39 9A-9.89 <br />Pump Units HSM -53 .50 .49 A6 A3 Al .38 .36 <br /> HSPF 9.90-10_39 10AO-l0_89 10.90-11.39 11.40-11.89 11.90-12.39 12AO & UP ----..-...---- <br /> HSM _34 .33 _31 .30 .29 .28 <br />PTHP COP 2-50-2_69 2.70-2_89 2.90-3_09 3_10-3.29 3_30-3A9 3.50-3_69 3.70-3_89 3.90-4.19 <br /> HSM .38 .37 .34 _32 _30 .29 .27 .26 <br />Electric Strin 1.0 ---------...---- <br />Gas & Other Fuels 1.0 (See Table 6A-18 for Credit Multiplier) -- <br />MINIMUMS: CENTRAL UNITS-AIR SOURCE SPLIT SYSTEM 6.8 HSPF, SINGLE PKG. 6.6 HSPF, WATER SOURCE 3.8 COP, GROUND WATER SOURCE 3.4 COP, PTHP 2.5-2.7 COP. <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION. <br /> <br />.5. <br />