Laserfiche WebLink
<br />Department of Community Affairs <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />Residential Whole Building Performance Method A <br />12962518 C BUILDER: HOMES OF MERIT <br />PERMITTING CLIMATE <br />OFFICE: ZONE: 41_1 51_1 61_1 <br />PERMIT NO. JURISDICTION NO. <br /> <br />1. New construction or addition <br />2. Single family detached or Multifamily attached <br />3. If Multifamily-No. of units <br />4. If Multifamily, is this a worst case (yes/no) <br />5. Conditioned floor area (sq.ft.) <br />6, Predominant eave overhang (ft.) <br />7. Porch overhang length (ft.) <br />8. Glass area and type: <br />a, Clear Glass <br />b. Tint, film or solar screen <br />9. Floor type and insulation: <br />b. Wood, raised (R-value, area) <br />10.Net Wall type area and insulation: <br />a. Exterior: 2. Wood frame (Insulation R-value) 10a~2 R=19.00, 1062.00sqft____ <br />11.Ceiling type area and insulation: <br />a. Under attic (Insulation R-value) <br />12.Air distribution systems <br />a. Ducts (Insulatioznale :LOCat~o. - <br />13. Cooling system Approved By KENNETH A. GODFREY <br /> <br />FORM 600A-93 <br />PROJECT NAME: <br />AND ADDRESS: <br /> <br />OWNER: <br /> <br />_ /}u1fi.~ <br /> <br />Modular BuildIng Plans Examln., <br />16.Hot Water Credits: (HR-He&~r'~~~ <br />DHP-Dedicated Heat Pump) <br />17. Infiltration practice: 1, 2 or 3 <br />18.HVAC Credits (CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, RB-Attic radiant <br />barrier, MZ-Multizone) <br />19.EPI (must not exceed 100 points) <br />a. Total As-Built points <br />b. Total Base points <br /> <br />14.Heating System: <br /> <br />15.Hot water system: <br /> <br />SN: 0000 <br /> <br />CENTRAL <br /> <br />CK <br /> <br />1. <br />2 . <br />3. <br />4. <br />5. 1387.00 <br />6. 1.33 <br />7. 0.00 <br />Single Pane <br />8a.149.8sqft <br />8b. O.Osqft <br /> <br />New Construction <br />Single-Family <br />o <br /> <br />Double Pane <br />O.OOsqft ____ <br />16.00sqft ____ <br /> <br />9b.R=11.00 , 1387.00 sqft ____ <br /> <br />11a.R=22.00 , 1430.00sqft____ <br /> <br />12a. R= 6.00, uncond <br />13. Type: Central A/C <br />SEER: 10.00 <br />14. Type: Heat Pump <br />HSPF: 7.50 <br />15. Type: Electric <br />EF: 0.93 <br /> <br />16. <br /> <br />17. <br />18. <br /> <br />2 <br /> <br />19. <br />19a. <br />19b. <br /> <br />82.09 <br />23898.18 <br />29111.02 <br /> <br />------------------------------------------------------------------------------- <br /> <br />------------------------------------------------------------------------------- <br /> <br />I Hereby certify that the plans and <br />specifications covered by this calcu- <br />lation are in compliance with the <br />Florida Energy COde! <br /> <br />PREPARED BY: ,{J, ~-~ <br />DATE: ':;:'/1 Cj7 <br /> <br />Review of the plans and specifications <br />covered by this calculation indicates <br />compliance with the Florida Energy <br />Code. Before construction is completed <br />this building will be inspected for <br />compliance in accordance with Section <br />553.908 F.S. <br /> <br />I hereby certify that this building is <br />in compliance with the Florida Energy <br />Code, <br /> <br />OWNER/AGENT: <br />DATE: <br /> <br />BOI~ING OFFICIAL: <br />~::;-- <br />