My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
98-8052
Zephyrhills
>
Building Department
>
Permits
>
1998
>
98-8052
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 3:15:44 PM
Creation date
8/23/2006 3:51:58 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
98-8052
Building Department - Name
WILLIAMS,CHARLES
Address
3341 MALACHITE LOT 44
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />- - > <br /> <br /> <br />City of Zephyrhills <br />Building Department <br /> <br />5335 Eighth Street <br /> <br />Zephyrhills, Florida 33540 <br /> <br />(813) 788-6611 <br /> <br />Fax (813) 788-5262 <br /> <br />W.A, "Bill Burgess <br />Director of Building <br />Licensing & Zoning <br /> <br />Electrical Notes <br />10/07/98 <br /> <br />210-52. Dwelling Unit Receptacle Outlets. <br /> <br />(a) General Provisions. In every kitchen, family room, dining room, living room, parlor, library, <br />den, sun room, bedroom, recreation room, or similar room or area of dwelling units, receptacle <br />outlets shall be installed so that no point along the floor line in any wall space is more than 6 ft (1.83 <br />m), measured horizontally, from an outlet in that space, including any wall space 2 ft (610 mm) or <br />more in width and the wall space occupied by fixed panels in exterior walls, but excluding sliding <br />panels in exterior walls, The wall space afforded by fixed room dividers, such as freestanding bar- <br />type counters or railings, shall be included in the 6-ft (1.83-m) measurement. <br /> <br />As used in this section, a "wall space" shall be considered a wall unbroken along the floor line by <br />doorways, fireplaces, and similar openings. Each wall space 2 ft or more (610 mm or more) wide <br />shall be treated individually and separately from other wall spaces within the room. A wall space <br />shall be permitted to include two or more walls ofa room (around comers) where unbroken at the <br />floor line. <br /> <br />Receptacle outlets shall, insofar as practicable, be spaced equal distances apart. Receptacle outlets in <br />floors shall not be counted as part of the required number of receptacle outlets unless located within <br />18 in, (457 mm) of the wall. <br /> <br />The receptacle outlets required by this section shall be in addition to any receptacle that is part of <br />any lighting fixture or appliance, located within cabinets or cupboards, or located over 5 1/2 ft (1.68 <br />m) above the floor. <br /> <br />Exception: Permanently installed electric baseboard heaters equipped with factory-installed <br />receptacle outlets or outlets provided as a separate assembly by the manufacturer shall be permitted <br />as the required outlet or outlets for the wall space utilized by such permanently installed heaters. <br />Such receptacle outlets shall not be connected to the heater circuits, <br /> <br />(FPN): Listed baseboard heaters include instructions that may not permit their installation below <br />receptacle outlets. <br /> <br />210-70, Lighting Outlets Required. <br /> <br />Lighting outlets shall be installed where specified in Sections 21O-70(a), (b), and (c) below, <br /> <br />(a) Dwelling Unit(s). At least one wall switch-controlled lighting outlet shall be installed in every <br />habitable room; in bathrooms, hallways, stairways, attached garages, and detached garages with <br />electric power; and at the exterior side of outdoor entrances or exits, A vehicle door in a garage shall <br />not be considered as an outdoor entrance or exit. <br />
The URL can be used to link to this page
Your browser does not support the video tag.