<br /> <br />City of Zephyrhills <br />Building Department <br /> <br />5335 Eighth Street <br /> <br />Zephyrhills, Florida 33540 <br /> <br />(813) 788-6611 <br /> <br />Fax (813) 788-5262 <br /> <br />W,A. "Bill Burgess <br />Director of Building <br />licensing & Zoning <br /> <br />Electrical Notes <br />10/26/98 <br /> <br />210-52. Dwelling Unit Receptacle Outlets. <br /> <br />(a) General Provisions, In every kitchen, family room, dining room, living room, parlor, library, <br />den, sun room, bedroom, recreation room, or similar room or area of dwelling units, receptacle <br />outlets shall be installed so that no point along the floor line in any wall space is more than 6 ft (1.83 <br />m), measured horizontally, from an outlet in that space, including any wall space 2 ft (610 mm) or <br />more in width and the wall space occupied by fixed panels in exterior walls, but excluding sliding <br />panels in exterior walls. The wall space afforded by fixed room dividers, such as freestanding bar- <br />type counters or railings, shall be included in the 6-ft (l,83-m) measurement, <br /> <br />As used in this section, a "wall space" shall be considered a wall unbroken along the floor line by <br />doorways, fireplaces, and similar openings. Each wall space 2 ft or more (610 mm or more) wide <br />shall be treated individually and separately from other wall spaces within the room. A wall space <br />shall be permitted to include two or more walls of a room (around comers) where unbroken at the <br />floor line. <br /> <br />Receptacle outlets shall, insofar as practicable, be spaced equal distances apart. Receptacle outlets in <br />floors shall not be counted as part ofthe required number of receptacle outlets unless located within <br />18 in. (457 mm) of the walL <br /> <br />The receptacle outlets required by this section shall be in addition to any receptacle that is part of <br />any lighting fixture or appliance, located within cabinets or cupboards, or located over 5 1/2 ft (1.68 <br />m) above the floor. <br /> <br />Exception: Permanently installed electric baseboard heaters equipped with factory-installed <br />receptacle outlets or outlets provided as a separate assembly by the manufacturer shall be permitted <br />as the required outlet or outlets for the wall space utilized by such permanently installed heaters. <br />Such receptacle outlets shall not be connected to the heater circuits. <br /> <br />(FPN): Listed baseboard heaters include instructions that may not permit their installation below <br />receptacle outlets. <br /> <br />(e) Outdoor Outlets. For a one-family dwelling and each unit of a two-family dwelling that is at <br />grade level, at least one receptacle outlet accessible at grade level and not more than 6 ft, 6 in. (1.98 <br />m) above grade shall be installed at the front and back of the dwelling. See Section 210-8(a)(3), <br /> <br />210-70. Lighting Outlets Required. <br /> <br />Lighting outlets shall be installed where specified in Sections 21O-70(a), (b), and (c) below. <br />