<br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br />FORM 500 A-93 CHAPTER 5 · BUILDING DESIGN BY COMPONENT PERFORMANCE APPROACH
<br />Non.Resldentlal Buildings ADMINISTERED BY THE DEPARTMENT OF COMMUNITY AFFAIRS
<br />Residential Buildings over 3 stories ALL CLIMATE ZONES
<br />
<br />PROJECT NAME:
<br />ADDRESS:
<br />CITY. ZIP CODE:
<br />BUILDER:
<br />OWNER:
<br />
<br />ZONE:
<br />BUILDING CLASSIFICATION S :
<br />BUILDING PERMIT NO.: 0
<br />PERMITTING OFFICE:
<br />JURISDICTION NO.:
<br />
<br />
<br /> BUILDING INFORMATION
<br />WALLS ROOF/CEILING FLOORS DOORS GLASS
<br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA
<br />Concrete ICBS) dilL Il"1U Under attic i,'j ;).\~c.:.. Slab-on-grade C) 1'l.<:7( - Wood Single, wall ,G;) ;}.J.{., ")
<br />Wood frame , Single Assembly Raised Wood Metal I'it..' '51.\( Double, wall
<br />Metal frame Other: Raised concrete Insulated Single. roof
<br />Insulation R-value Insulation R-value Insulation R-value Other Double, roof
<br />
<br /> SYSTEMS INFORMATION
<br />AIR CONDITIONER HEATING SYSTEM HOT WATER
<br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTU/H TYPE
<br />Unitary & Heat Pump -- Central & Heat Pump ,,-(.uW Electric ~
<br /><65,000 Btu/h II,) ,t"sEER ------L < 65,000 Btu / h ..:1& HSPF Resistance
<br />,,65.000 Btu/h EER IPLV ~65,000 Btu/h _COP - Dedicated Heat Pump
<br /> - - - Water cooled _COP Gas
<br /> -
<br />Water Cooled - EER - IPLV - Evaporatively cooled _COP Natural 0
<br /> -
<br />Evaporatively Cooled - EER - Electric resistance _COP LPG 0
<br /> -
<br />PTAC - EER - Gas/Oillcircle one) Oil 0
<br />Chillers COP IPLV < 225.000/300,000 Btu/h _ AFUE - HRU 0
<br />- - -
<br />Other: ~ 225,000/300,000 Btu/h Et Other:
<br />UGHTING Total Lighting Wattage 1 a:.>UD = . '?( .~ Lighting Budget: -:.z..... DUCTS R-value: 0
<br />=
<br /> Total Conditioned Floor Area J..~If~ Wattslsq,ft, (from Table 5-13)
<br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.)
<br />COMPONENTS SECTION REQUIREMENTS CHECK
<br />Windows 502.4 Maximum of .37 cfm per linear foot of operable sash crack. ~
<br />Doors 502.4 Maximum of 1.25 cfm per square foot of door area. >-
<br />Joints/Cracks 502.4 To be caulked, gasketed, weatherstripped or otherwise sealed. "'-
<br />Reheat 503.3 Supply air restricted to set cold/hot deck temperature to meet load of worst case zone. Resistance reheat prohibited. Iv 11
<br />Ventilation 503.4 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required. '"
<br />HV AC Efficiency 503.4 Minimum efficiencies-Heating: Tables 5-4,5-5 & 5-6. Cooling: Tables 5'7A, 5'7B, 5-8 & 5-9. "".
<br />Transport Energy 503.5 Minimum of 8.0. -{..,
<br />Balancing 503.6 Provide means for balancing HVAC air system & water distribution system. "-
<br />HV AC Controls 503.7 Separate readily accessible manual or automatic thermostat for each system. 7'
<br />HV AC Ducts 503.8 Air ducts. fittings, mechanical equipment and plenum chambers shall be mechanically attached. sealed.
<br /> 503.9 insulated and installed in accordance with the criteria of sections 503.8, 503.9 and 503.10. l
<br /> 503.10
<br />Piping Insulation 503.11 In accordance with Table 5-10. ..,..
<br />Water Heaters 504.2 Automatic electric storage water heaters s 120 gallons and gas & oil-fired storage water heaters s 75,000 BlUIh shall
<br /> meet performance minimums in Table 5-11. Electric> 120 gallons: standby loss < .30+27NT' Gas> 75,000, Oil> ),
<br /> 105,000: Et .78, Standby loss 1.30 + 114NT' Gas, Oil> 155,000: E, .78, standby loss 1.30 + 95NT'
<br />Swimming Pools 504.2 Spas & heated pools must have covers. Non'commercial pools must have pump timer. IJ~
<br />& Spas Gas spa & pool heaters must have minimum thermal efficiency of 78%.
<br />Hot Water Pipe 504.4 Piping heat loss is limited to 17.5 Btu/h linear foot of pipe for recirculating systems (see Table 5-12). ~~hi
<br />Insulation
<br />Water Fixtures 504.5 Water flow restricted to maximum of 3 gpm at 80 psig; toilets maximum 3.5 gallon flush. .)-.
<br /> Public lavatory fixture maximum flow of .5 gpm or .5 gallon if has self-closing valve.
<br />Lig hti ng 505.1 Lighting power budgets are listed in Table 5'13. Minimum Ballast Efficacy Factors are listed in Table 5-14. . 't--.
<br />
<br />Uo wall Allowable .-~ U 0 wa II Actual I.J.~ If complying under the provisions of S. 502.2 enter the combined Uo values for the entire envelope
<br />Uo roof I ceiling Allowable Uo rool/ ceiling Actual in this section.
<br />Uo floor Allowable Uo floor Actual Uo envelope Allowable Uo envelope Actual
<br />OTTV wall Allowable II V OTTV wall Actual 1<IA.,,( 'IJ
<br />OTTV rool/ceiling Allowable L' ()'" OTTV roof I ceiling Actual ......,' )./
<br />
<br />Compliance with Chapter 5was demonstrated by a Prescriptive Measures methodology:
<br />D 508.0 (a) Detached commercial buildings D 508.0 (b) Skyboxes or sports stadium buildings
<br />less than 100 square feet. that are used only seasonally.
<br />
<br />I hereby certify that
<br />with the Florida Ene
<br />PREPARED BY:
<br />I hereby certify that this building is .
<br />
<br />OWNER/AGENT:
<br />
<br />
<br />D 508,O(c) Traffic safety
<br />control towers
<br />
<br />DATE: /U,"-.)f-tf}
<br />Florida Energy Code.
<br />DATE:
<br />
<br />Review of plans and specifications covered by this calculation indicates compliance with the
<br />Florida Energy Code. ~for nstruction is co~. ted, this building will be inspected for
<br />Nompliance in accord. ce ~~~53.908 _ .8/
<br />or BUILDING OFFICI : J...t:,.-j .~'-
<br />
<br />DATE: A .
<br />