Laserfiche WebLink
<br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />FORM 500 A-93 CHAPTER 5 · BUILDING DESIGN BY COMPONENT PERFORMANCE APPROACH <br />Non.Resldentlal Buildings ADMINISTERED BY THE DEPARTMENT OF COMMUNITY AFFAIRS <br />Residential Buildings over 3 stories ALL CLIMATE ZONES <br /> <br />PROJECT NAME: <br />ADDRESS: <br />CITY. ZIP CODE: <br />BUILDER: <br />OWNER: <br /> <br />ZONE: <br />BUILDING CLASSIFICATION S : <br />BUILDING PERMIT NO.: 0 <br />PERMITTING OFFICE: <br />JURISDICTION NO.: <br /> <br /> <br /> BUILDING INFORMATION <br />WALLS ROOF/CEILING FLOORS DOORS GLASS <br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA <br />Concrete ICBS) dilL Il"1U Under attic i,'j ;).\~c.:.. Slab-on-grade C) 1'l.<:7( - Wood Single, wall ,G;) ;}.J.{., ") <br />Wood frame , Single Assembly Raised Wood Metal I'it..' '51.\( Double, wall <br />Metal frame Other: Raised concrete Insulated Single. roof <br />Insulation R-value Insulation R-value Insulation R-value Other Double, roof <br /> <br /> SYSTEMS INFORMATION <br />AIR CONDITIONER HEATING SYSTEM HOT WATER <br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTU/H TYPE <br />Unitary & Heat Pump -- Central & Heat Pump ,,-(.uW Electric ~ <br /><65,000 Btu/h II,) ,t"sEER ------L < 65,000 Btu / h ..:1& HSPF Resistance <br />,,65.000 Btu/h EER IPLV ~65,000 Btu/h _COP - Dedicated Heat Pump <br /> - - - Water cooled _COP Gas <br /> - <br />Water Cooled - EER - IPLV - Evaporatively cooled _COP Natural 0 <br /> - <br />Evaporatively Cooled - EER - Electric resistance _COP LPG 0 <br /> - <br />PTAC - EER - Gas/Oillcircle one) Oil 0 <br />Chillers COP IPLV < 225.000/300,000 Btu/h _ AFUE - HRU 0 <br />- - - <br />Other: ~ 225,000/300,000 Btu/h Et Other: <br />UGHTING Total Lighting Wattage 1 a:.>UD = . '?( .~ Lighting Budget: -:.z..... DUCTS R-value: 0 <br />= <br /> Total Conditioned Floor Area J..~If~ Wattslsq,ft, (from Table 5-13) <br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Windows 502.4 Maximum of .37 cfm per linear foot of operable sash crack. ~ <br />Doors 502.4 Maximum of 1.25 cfm per square foot of door area. >- <br />Joints/Cracks 502.4 To be caulked, gasketed, weatherstripped or otherwise sealed. "'- <br />Reheat 503.3 Supply air restricted to set cold/hot deck temperature to meet load of worst case zone. Resistance reheat prohibited. Iv 11 <br />Ventilation 503.4 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required. '" <br />HV AC Efficiency 503.4 Minimum efficiencies-Heating: Tables 5-4,5-5 & 5-6. Cooling: Tables 5'7A, 5'7B, 5-8 & 5-9. "". <br />Transport Energy 503.5 Minimum of 8.0. -{.., <br />Balancing 503.6 Provide means for balancing HVAC air system & water distribution system. "- <br />HV AC Controls 503.7 Separate readily accessible manual or automatic thermostat for each system. 7' <br />HV AC Ducts 503.8 Air ducts. fittings, mechanical equipment and plenum chambers shall be mechanically attached. sealed. <br /> 503.9 insulated and installed in accordance with the criteria of sections 503.8, 503.9 and 503.10. l <br /> 503.10 <br />Piping Insulation 503.11 In accordance with Table 5-10. ..,.. <br />Water Heaters 504.2 Automatic electric storage water heaters s 120 gallons and gas & oil-fired storage water heaters s 75,000 BlUIh shall <br /> meet performance minimums in Table 5-11. Electric> 120 gallons: standby loss < .30+27NT' Gas> 75,000, Oil> ), <br /> 105,000: Et .78, Standby loss 1.30 + 114NT' Gas, Oil> 155,000: E, .78, standby loss 1.30 + 95NT' <br />Swimming Pools 504.2 Spas & heated pools must have covers. Non'commercial pools must have pump timer. IJ~ <br />& Spas Gas spa & pool heaters must have minimum thermal efficiency of 78%. <br />Hot Water Pipe 504.4 Piping heat loss is limited to 17.5 Btu/h linear foot of pipe for recirculating systems (see Table 5-12). ~~hi <br />Insulation <br />Water Fixtures 504.5 Water flow restricted to maximum of 3 gpm at 80 psig; toilets maximum 3.5 gallon flush. .)-. <br /> Public lavatory fixture maximum flow of .5 gpm or .5 gallon if has self-closing valve. <br />Lig hti ng 505.1 Lighting power budgets are listed in Table 5'13. Minimum Ballast Efficacy Factors are listed in Table 5-14. . 't--. <br /> <br />Uo wall Allowable .-~ U 0 wa II Actual I.J.~ If complying under the provisions of S. 502.2 enter the combined Uo values for the entire envelope <br />Uo roof I ceiling Allowable Uo rool/ ceiling Actual in this section. <br />Uo floor Allowable Uo floor Actual Uo envelope Allowable Uo envelope Actual <br />OTTV wall Allowable II V OTTV wall Actual 1<IA.,,( 'IJ <br />OTTV rool/ceiling Allowable L' ()'" OTTV roof I ceiling Actual ......,' )./ <br /> <br />Compliance with Chapter 5was demonstrated by a Prescriptive Measures methodology: <br />D 508.0 (a) Detached commercial buildings D 508.0 (b) Skyboxes or sports stadium buildings <br />less than 100 square feet. that are used only seasonally. <br /> <br />I hereby certify that <br />with the Florida Ene <br />PREPARED BY: <br />I hereby certify that this building is . <br /> <br />OWNER/AGENT: <br /> <br /> <br />D 508,O(c) Traffic safety <br />control towers <br /> <br />DATE: /U,"-.)f-tf} <br />Florida Energy Code. <br />DATE: <br /> <br />Review of plans and specifications covered by this calculation indicates compliance with the <br />Florida Energy Code. ~for nstruction is co~. ted, this building will be inspected for <br />Nompliance in accord. ce ~~~53.908 _ .8/ <br />or BUILDING OFFICI : J...t:,.-j .~'- <br /> <br />DATE: A . <br /> <br /> <br />