<br />SECTION 9 FASTENERS <br /> Table 9.2: FASTENERS FOR ENCLOSED BUILDINGS I LOADS I ROOF AREAS <br /> Maximum Allowable - Load and Attributable Roof Area 120 MPH Wind Zone (41#/Sq. Ft.) <br /> (For Wind Regions other than 120 MPH, Use Conversion Table at Bottom of this page) <br /> CONNECTING TO: WOOD for ENCLOSED Buildinas <br /> Fastener Le ngth of Number of Fasteners <br /> Diameter Embedment 1 2 3 4 <br /> 1/4"" 1" 264# - 6 SF 528# - 13 SF 792# - 19 SF 1056# - 26 SF <br /> . <br /> 1/4" " 1-1/2" 396# - 10 SF 792# - 19 SF 1188# - 29 SF 1584# - 39 SF <br /> 1/4" " 2-1/2" 660# - 16 SF 1320# - 32 SF 1980# - 48 SF 2640# - 64 SF <br /> 5/16" " 1" 312# - 8 SF 624# - 15 SF 936# - 23 SF 1248# - 30 SF <br /> 5/16"" 1-112" 468# - 11 SF 936# - 23 SF 1404# - 34 SF 1872# - 46 SF <br /> 5/16" " 2-1/2" 780# - 19 SF 1560# - 38 SF 2340# - 57 SF 3120# - 76 SF <br /> 3/8"" 1" 356# - 9 SF 712# - 17 SF 1 068# - 26 SF 1424# - 35 SF <br /> 3/8"" 1-1/2" 534# - 13 SF 1068# - 26 SF 1602# - 39 SF 2136# - 52 SF <br /> 3/8"" 2-1/2" 890# - 22 SF 1780#.43 SF 2670# - 65 SF 3560# - 87 SF <br /> CONNECTING TO: CONCRETE [Min. 2,500 psi] for ENCLOSED Buildings <br /> Fastener Length of I Number of Fasteners <br /> Diameter Embedment 1 2 3 4 <br /> TYPE OF FASTENER = Concrete Screw (Rawl Tapper or Equivalent) <br /> 3/16" " 1-1/4" I 343# - 8 SF I 686# - 17 SF I 1029# - 25 SF 1372# - 33 SF <br /> 1/4"" 1-1/4" I 512# - 12 SF I 1024# - 25 SF I 1536# - 37 SF I 2048# - 50 SF <br /> TYPE OF FASTENER = 'Quick Set' Concrete Screw (Rawl Zamac Nallln or Equivalent) <br /> 1/4"" 114" 227# - 6 SF 454# - 11 SF 681# - 17 SF 908# - 22 SF <br /> TYPE OF FASTENER = Expansion Bolts CRawl-Bolt or Eauivalentl ' <br /> 114"" 2" 568# - 14 SF 1136# - 28 SF 1704# - 42 SF 2272# - 55 SF <br /> 3/8"" 2-114" 1441# - 35 SF 2882# - 70 SF 4323# - 105 SF 5764# - 141 SF <br /> 1/2" " 3" 1985# - 48 SF 3970# - 97 SF 5955# - 145 SF 7940# - 194 SF <br /> CONNECTING: POSTS to BEAMS usina BOLTS for ENCLOSED Bulldinas <br /> Fastener Number of Fasteners <br /> Diameter 1 2 3 <br /> # -SF I-SF I-SF <br /> 1/4"" * 1468 - 36 2936 - 72 4404 - 107 <br /> 3/8"" * 3710 - 90 7420 - 181 11130 - 271 <br /> 1/2"" * 6596 - 161 13192 - 322 19788 - 483 <br /> * Length of Bolt to be Size of Post +Yo" (Typical) <br /> WIND LOAD CONVERSION TABLE: WIND CONVERSION <br /> For Wind Zones/Regions other than 120 MPH (Tables Shown), REGION FACTOR <br /> multiply allowable loads and roof areas by the conversion factor. 102 1.41 <br /> 110 1.17 <br /> 120 1,00 <br /> 125 0,91 <br /> 140 0.73 <br /> Lawrence E. Bennett, P.E. <br /> aw. EIGEER - 0EVElQPI&IT CONSU.TANr <br /> P.O. BOX 4388, SOUTH DAYTONA, FL 32121 <br /> TB..EPHOfE (1104) 787-4774 <br /> FAX (1104) 787-81558 <br />SEAL <br />PAGE @ COPYRIGHT 1998 <br />142 NOT TO BE REPRODUCED N WHOlE OR N PART WITHOUT TIE WFITTEN PSlMISSlON OF LAWRENCE E BENETT, P.E. <br />