<br />ADDITIONAL TABLES
<br />
<br />CLIMATE ZONES 4 5 6
<br />
<br />6A.18 HEATING CREDIT MULTIPLIERS tHCM)
<br />SYSTEM TYPE HEATING CREDIT MULTIPLIERS tHCM)
<br />Allic Radiant Barrier HCM ,98
<br />Multizone HCM .95
<br />Natural Gas AFUE ,68-.72 .73-.77 .78-.82 ,83-.87 .88-,92 ,93 & Uo
<br /> HCM .61 ,56 .53 ,50 ,47 .44
<br />LP Gas HCM .77 ,72 .67 ,63 ,60 .57
<br />
<br />6A.19 COOLING CREDIT MULTIPLIERS CCM)
<br />SYSTEM TYPE COOLING CREDIT MULTIPLIERS tCCM!
<br />Ceilina Fans .86'
<br />Cross Ventilation .95' 'Credit may be taken for only
<br />Whole House Fan .95'
<br />Multizone ,95 one of these system types concurrenlly.
<br />Allic Radiant Barrier ,95
<br />
<br />
<br />Heat Recovery Unit
<br />
<br />
<br />Dedicated Heat Pump
<br />
<br />Solar
<br />
<br />A HWM MUST BE USED IN CONJUNCTION WITH ALL HWCM. SEE TABLE 6A-9. EF MEANS ENERGY FACTOR.
<br />
<br />6A-21 INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST tSEE SECTION 606)
<br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK
<br />PRACTICE #1 606.1 COMPLY WITH AlllNFll TRATION PRESCRIPTIVES,
<br />Windows Maximum of 0,34 CFM oer linear foot of operable sash crack (includes slidina alass doors).
<br />Exterior & Adiacent Doors Maximum of 0,5 CFM oer sa. ft. of door area' solid core, wood oanel insulated or alass doors only,
<br />Exterior Joints & Cracks To be caulked. aasketed weatherstriooed or otherwise sealed,
<br />PRACTICE #2 606,1 COMPLY WITH #1 AND THE FOllOWING:
<br />Exterior Walls and Floors Top plate penetrations sealed, Infiltration barrier installed, Sole olate/floor ioint caulked or sealed.
<br />Exterior Walls & Ceilinas Penetrations ioints and cracks on interior surface caulked sealed or aasketed,
<br />Ductwork Ductwork in unconditioned soace must be sealed,
<br />Fireolaces Eauipped with outside combustion air doors, and flue damoers.
<br />Exhaust Fans Eauioped with damoers, Combustion devices see 606,1.A.2
<br />PRACTICE #3 606.1 COMPLY WITH PRACTICES #1 AND #2 AND THE FOllOWING:
<br />Ceilinas Infiltration barrier installed,
<br />Interior Walls Top penetrations sealed or ioints & cracks on interior walls caulked sealed or nasketed,
<br />Recessed Liahts Sealed from conditioned & insulated from ventilated attic soaces.
<br />Ductwork All ductwork located in conditioned soace.
<br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust
<br /> by-products to outside. Combustion cooking appliances see section 606.1.A.3
<br />
<br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.!
<br />COMPONENTS SECTION REQUIREMENTS CHECK
<br />Water Heaters 612,1 Comply with efficiency requirements in Table 6-11, Switch or clearly marked circuit breaker (electric)
<br /> or cutoff {a as) must be orovided, External or built-in heat trap reauired.
<br />Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated), Non-commercial poolS must have
<br /> a pump timer. Gas soa & 0001 heaters must have a minimum thermal efficiencv of 78%,
<br />Shower Heads 612.1 Water flow must be restricted to no more than 3 aallons per minute at 80 PSIG.
<br />Air Distribution System 610,1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached,
<br /> sealed, insulated, and installed in accordance with the criteria of Section 610, Ducts in unconditioned
<br /> attics must be insulated to a minimum of R-6, Air handlers shall not be installed in attics unless in
<br /> mechanical closet.
<br />HVAC Controls 607,1 Separate readilv accessible manual or automatic thermostat for each system.
<br />Insulation 604.1, 602,1 Ceilings-Min. R-19, Common walls-Frame R-11 orCBS R-3 both sides, Common ceilina & floors R-11,
<br />